Phase Current Reconstruction for the Grid-Sae Converter With Four-Switch Three-Phase Topology in a DFIG-WT

被引:6
作者
Ni, Kai [1 ]
Li, Wei [2 ]
Liu, Yang [3 ]
Yu, Dongsheng [4 ]
Hu, Yihua [1 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
[2] State Grid Int Dev Co Ltd, Beijing 100031, Peoples R China
[3] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510640, Guangdong, Peoples R China
[4] China Univ Min & Technol, Sch Elect & Power Engn, Xuzhou 221116, Jiangsu, Peoples R China
基金
中国博士后科学基金;
关键词
Reliability; doubly-fed induction generator-based wind turbine; grid-side converter; four-switch three-phase; phase current reconstruction; space vector pulse width modulation; SINGLE CURRENT SENSOR; DC-LINK CURRENT; INVERTERS; DRIVE; INJECTION; SCHEME; DTC;
D O I
10.1109/ACCESS.2018.2853761
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To increase the reliability of a doubly fed induction generator-based wind turbine (DFIG-WT), this paper proposes a fault-tolerant four-switch three-phase (FSTP) grid-side converter (GSC) with a phase current reconstruction strategy. The proposed strategy is effective when the semiconductor open-circuit fault and phase current sensor failure occur simultaneously, which is a kind of hybrid fault. Only one current sensor is applied for measuring the currents flowing between the ac and dc sides of the GSC, and the phase current information can be derived by combining this information with the switching states of FSTP GSC. In the proposed current reconstruction strategy, only two scenarios of duty ratio allocation are needed to be considered. In addition, the space vector pulsewidth modulation (SVPWM) technique is simplified by obtaining the unified expressions for the duty ratios for the remaining four switches in GSC, and the sector identification is removed. Besides, the voltage balancing on the dc bus is achieved. Furthermore, the limitation of the proposed current reconstruction strategy is presented, and the dead zones for SVPWM techniques in both six-switch three-phase and FSTP converters are analyzed. Simulations are carried out in MATLAB/Simulink to verify the proposed hybrid fault-tolerant strategy for the GSC in a 1.5-MW DFIG-WT.
引用
收藏
页码:39287 / 39297
页数:11
相关论文
共 35 条
[1]   A Rotor-Current-Based Slip Angle Estimator for Grid-Connected Doubly Fed Induction Generator Requiring the Stator Inductance Only [J].
Ataji, Ahmad Bashar ;
Miura, Yushi ;
Ise, Toshifumi ;
Tanaka, Hiroki .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (06) :4827-4838
[2]   Second-Order Sliding Mode Control of a Doubly Fed Induction Generator Driven Wind Turbine [J].
Beltran, Brice ;
Benbouzid, Mohamed El Hachemi ;
Ahmed-Ali, Tarek .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (02) :261-269
[3]   Single current sensor technique in the DC link of three-phase PWM-VS inverters: A review and a novel solution [J].
Blaabjerg, F ;
Pedersen, JK ;
Jaeger, U ;
Thoegersen, P .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (05) :1241-1253
[4]   NOVEL CURRENT SENSOR FOR PWM AC DRIVES [J].
BOYS, JT .
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1988, 135 (01) :27-32
[5]   Direct Stator Current Vector Control Strategy of DFIG Without Phase-Locked Loop During Network Unbalance [J].
Cheng, Peng ;
Nian, Heng ;
Wu, Chao ;
Zhu, Z. Q. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (01) :284-297
[6]   A Three-Phase Current Reconstruction Strategy With Online Current Offset Compensation Using a Single Current Sensor [J].
Cho, Younghoon ;
LaBella, Thomas ;
Lai, Jih-Sheng .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (07) :2924-2933
[7]   Sensorless Control of Doubly Fed Induction Generators Based on Stator High-Frequency Signal Injection [J].
Diaz Reigosa, David ;
Briz, Fernando ;
Blanco, Cristian ;
Manuel Guerrero, Juan .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (05) :3382-3391
[8]   DTC Scheme for a Four-Switch Inverter-Fed Induction Motor Emulating the Six-Switch Inverter Operation [J].
El Badsi, Bassem ;
Bouzidi, Badii ;
Masmoudi, Ahmed .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (07) :3528-3538
[9]   Fault-Tolerant PMSG Drive With Reduced DC-Link Ratings for Wind Turbine Applications [J].
Freire, Nuno M. A. ;
Marques Cardoso, Antonio J. .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2014, 2 (01) :26-34
[10]   Phase Current Reconstruction of Switched Reluctance Motors From DC-Link Current Under Double High-Frequency Pulses Injection [J].
Gan, Chun ;
Wu, Jianhua ;
Yang, Shiyou ;
Hu, Yihua .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (05) :3265-3276