Effect of injection duration on contrast enhancement during cardiac computed tomography angiography in newborns and infants

被引:2
|
作者
Masuda, T. [1 ]
Funama, Y. [2 ]
Nakaura, T. [3 ]
Sato, T. [4 ]
Tahara, M. [5 ]
Masuda, S. [6 ]
Yoshiura, T. [7 ]
Gotanda, R. [1 ]
Arao, K. [1 ]
Imaizumi, H. [1 ]
Arao, S. [1 ]
Hiratsuka, J. [1 ]
Awai, K. [8 ]
机构
[1] Kawasaki Univ Med Welf, Fac Hlth Sci & Technol, Dept Radiol Technol, 288 Matsushima, Kurashiki, Okayama 7010193, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, 1-1-1 Honjo, Kumamoto 8608556, Japan
[3] Kumamoto Univ, Fac Life Sci, Dept Med Phys, 1-1-1 Honjo, Kumamoto 8608556, Japan
[4] Tsuchiya Gen Hosp, Dept Diagnost Radiol, Nakajima Cho 3-30,Naka Ku, Hiroshima 7308655, Japan
[5] Tsuchiya Gen Hosp, Dept Pediat Cardiol, Nakajima Cho 3-30,Naka Ku, Hiroshima 7308655, Japan
[6] Kawamura Clin, Dept Radiol Technol, Naka Ku, Otemachi, Hiroshima 7300051, Japan
[7] Tsuchiya Gen Hosp, Dept Radiol Technol, Nakajima Cho 3-30,Naka Ku, Hiroshima 7308655, Japan
[8] Hiroshima Univ, Grad Sch Biomed Sci, Dept Diagnost Radiol, Kasumi 1-2-3 Minami Ku, Hiroshima 7348551, Japan
关键词
Cardiac computed tomography angiography; Contrast enhancement; Pediatric; Contrast medium; Congenital heart disease; POWER INJECTOR; SAFE USE; CT; EXTRAVASATION; CHILDREN; MEDIA; ACCURACY; SOCIETY;
D O I
10.1016/j.radi.2021.11.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: To investigate how changing the injection duration at cardiac computed tomography angiography (CCTA) affects contrast enhancement in newborns and infants. Methods: Included were 142 newborns and infants with confirmed congenital heart disease who underwent CCTA between January 2015 and December 2018. In group 1 (n = 71 patients), the injection duration was 8 s; in group 2 (n = 71) it was 16 s. Our findings were assessed by one-to-one matching analysis to estimate the propensity score of each patient. We compare the CT number for the pulmonary artery (PA), ascending aorta (AAO), left superior vena cava (SVC), AAO and PA enhancement ratio, and the scores for visualization between the two groups. Results: In group 1, median CT number and ranges was 345 (211-591) HU in the AAO, 324 (213-567) HU in the PA, and 62 (1-70) HU in the SVC. These values were 465 (308-669) HU, 467 (295-638) HU, and 234 (67-443) HU, respectively, in group 2 (p < 0.05). The median score for volume-rendering visualization on 3D images of the CCTA was 2 in group 1 and 3 in group 2; the score for visualization of the left SVC of the maximum intensity projection images was 2 in group 1 and 3 in group 2 (p < 0.05). The CT number for the AAO and PA enhancement ratio was 15.2 in group 1 and 9.2 in group 2 (p < 0.05). Conclusion: The 16-sec injection protocol yielded significantly higher CT numbers for the AAO, PA, and the SVC than the 8-sec injection protocol; the visualization scores were also significantly higher in group 2. Implications for practice: In newborns and infants, the longer injection time for CCTA yields stable and higher contrast enhancement at identical CM concentrations.
引用
收藏
页码:440 / 446
页数:7
相关论文
共 50 条
  • [21] Effect of cardiac function on aortic peak time and peak enhancement during coronary CT angiography
    Sakai, Shuji
    Yabuuchi, Hidetake
    Chishaki, Akiko
    Okafuji, Takashi
    Matsuo, Yoshio
    Kamitani, Takeshi
    Setoguchi, Taro
    Honda, Hiroshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (02) : 173 - 177
  • [22] The influence of cardiac function on coronary arterial enhancement at coronary computed tomography angiography: A cross-sectional study
    Moradi, Maryam
    Hashemi, Peiman
    Momeni, Mohammad
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2016, 21
  • [23] Cardiovascular computed tomography angiography in newborns and infants with suspected congenital heart disease: retrospective evaluation of low-dose scan protocols
    Klink, Thorsten
    Mueller, Goetz
    Weil, Jochen
    Dodge-Khatami, Ali
    Adam, Gerhard
    Bley, Thorsten Alexander
    CLINICAL IMAGING, 2012, 36 (06) : 746 - 753
  • [24] Towards Personalised Contrast Injection: Artificial-Intelligence-Derived Body Composition and Liver Enhancement in Computed Tomography
    de Jong, Daan J.
    Veldhuis, Wouter B.
    Wessels, Frank J.
    de Vos, Bob
    Moeskops, Pim
    Kok, Madeleine
    JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (03): : 1 - 13
  • [25] Utilization of cardiac computed tomography angiography and outpatient invasive coronary angiography in Ontario, Canada
    Roifman, Idan
    Rezai, Mohammad R.
    Wijeysundera, Harindra C.
    Chow, Benjamin J. W.
    Wright, Graham A.
    Tu, Jack V.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (06) : 567 - 571
  • [26] The utility of computed tomography and transfontanelle ultrasonography in various intracranial lesions in the newborns and infants Computed tomography and transfontanel ultrasonography in infants
    Dogen, Mehmet Ercument
    Ayaz, Umit Yasar
    Tuzun, O. Meric
    Durmaz, Hasan Ali
    Hekimoglu, Baki
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2021, 12 (09): : 1063 - 1067
  • [27] New Insight into Transient Contrast Enhancement on Computed Tomography after Endovascular Treatment of Stroke
    Antonucci, M. U.
    Mocco, J.
    Bennett, J. A.
    INTERVENTIONAL NEURORADIOLOGY, 2012, 18 (03) : 303 - 308
  • [28] A Novel Approach to Detecting Contrast Extravasation in Computed Tomography: Evaluating the Injection Pressure-to-Injection Rate Ratio
    Kobayashi, Naoki
    Nakaura, Takeshi
    Shiraishi, Kaori
    Uetani, Hiroyuki
    Nagayama, Yasunori
    Kidoh, Masafumi
    Oda, Seitaro
    Sakabe, Daisuke
    Ikeda, Ryuji
    Hatemura, Masahiro
    Murakami, Michiyo
    Funama, Yoshinori
    Hirai, Toshinori
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2025, 49 (01) : 125 - 132
  • [29] Two-Phase Contrast Injection Protocol for Pediatric Cardiac Computed Tomography in Children with Congenital Heart Disease
    Naoki Fukuyama
    Akira Kurata
    Naoto Kawaguchi
    Ryo Tashiro
    Takashi Higaki
    Takahiro Yokoi
    Yuki Tanabe
    Hikaru Nishiyama
    Toshihide Itoh
    Teruhito Kido
    Masao Miyagawa
    Teruhito Mochizuki
    Pediatric Cardiology, 2018, 39 : 518 - 525
  • [30] Two-Phase Contrast Injection Protocol for Pediatric Cardiac Computed Tomography in Children with Congenital Heart Disease
    Fukuyama, Naoki
    Kurata, Akira
    Kawaguchi, Naoto
    Tashiro, Ryo
    Higaki, Takashi
    Yokoi, Takahiro
    Tanabe, Yuki
    Nishiyama, Hikaru
    Itoh, Toshihide
    Kido, Teruhito
    Miyagawa, Masao
    Mochizuki, Teruhito
    PEDIATRIC CARDIOLOGY, 2018, 39 (03) : 518 - 525