Experimental evaluation of a radiation dose management system-integrated 3D skin dose map by comparison with XR-RV3 Gafchromic® films

被引:17
作者
Greffier, Joel [1 ]
Grussenmeyer-Mary, Nicolas [2 ]
Larbi, Ahmed [1 ]
Goupil, Jean [1 ]
Cayla, Guillaume [3 ]
Ledermann, Bertrand [3 ]
Beregi, Jean Paul [1 ]
Frandon, Julien [1 ]
机构
[1] Univ Montpellier, CHU Nimes, Med Imaging Grp Nimes, EA 2415,Serv Imagerie Med, Nimes, France
[2] GE Healthcare, DoseWatch, R&D, Strasbourg, France
[3] Univ Montpellier, CHU Nimes, Serv Cardiol, Med Imaging Grp Nimes,EA 2415, Nimes, France
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 66卷
关键词
Radiation physics; Fluoroscopy; Experimental; Dosimetry; Physics; Radiation safety; Dosimetric comparison; INTERVENTIONAL RADIOLOGY; RADIOCHROMIC FILM; PART I; CARDIOLOGY; INJURIES; RECOMMENDATIONS; CALIBRATION; VALIDATION; ACCURACY;
D O I
10.1016/j.ejmp.2019.09.234
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To assess the interactive Skin Dose Map (R) tool (SDMTool) integrated to the radiation dose management system (RDMS) DoseWatch (R) with Gafchromic (R) films for implementation in routine practice. Methods: A retrospective dose estimation software SDMTool was used to calculate Peak Skin Dose (PSD) and display the patient skin dose distribution. PSD was calculated with a triangle mesh of 0.055 cm(2) resolution on ICRP 110 male anthropomorphic phantom and with a square ROI of 1 cm(2) on flat phantom. The tool uses Radiation Dose Structured Reports (RDSR) data to model exposure events and calculate the PSD per event. The PSD and the skin dose distribution estimated with SDMTool were evaluated in comparison with Gafchromic (R) films positioned under the PMMA phantom (20 cm) for 13 configurations. Measurements were performed on a Philips system. Statistical analysis were carried out to compare PSDFilm and PSDSDM. Results: Average differences between PSDFilm and PSDSDM were 6% +/- 6% (range from -3% to 22%) for flat phantom and 5% +/- 7% (range from -3% to 25%) for ICRP phantom. Concordance was good between the measured PSDFilm and the estimated PSDSDM with Lin's coefficient estimation and 95% Confidence Interval of 0.979 [0.875; 0.984] for flat phantom and 0.977 [0.877; 0.985] for ICRP phantom. Dose map representations are concordant for 11 of the 13 tests on PMMA phantom. Disparities arose from the limitations of the RSDR format: table displacement during fluoroscopy events and the use of wedge filter. Conclusion: The results found in this experimental evaluation show that the SDMTool is a suitable alternative to Gafchromic (R) film to calculate PSD.
引用
收藏
页码:77 / 87
页数:11
相关论文
共 34 条
[1]  
[Anonymous], 2005, 74 IURU
[2]  
[Anonymous], 2002, ICRP PUBL
[3]   Fluoroscopically Guided Interventional Procedures: A Review of Radiation Effects on Patients' Skin and Hair [J].
Balter, Stephen ;
Hopewell, John W. ;
Miller, Donald L. ;
Wagner, Louis K. ;
Zelefsky, Michael J. .
RADIOLOGY, 2010, 254 (02) :326-341
[4]  
Bednarek D R., 2011, Proc SPIE Int Soc Opt Eng, V7961
[5]   ACCURACY OF A DOSE MAP METHOD ASSESSED IN CLINICAL AND ANTHROPOMORPHIC PHANTOM SITUATIONS USING GAFCHROMIC FILMS [J].
Bordier, C. ;
Klausz, R. ;
Desponds, L. .
RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) :244-249
[6]   Patient dose map indications on interventional X-ray systems and validation with Gafchromic XR-RV3 film [J].
Bordier, C. ;
Klausz, R. ;
Desponds, L. .
RADIATION PROTECTION DOSIMETRY, 2015, 163 (03) :306-318
[7]  
Clarke Roger, 2009, Annals of the ICRP, V39, P1, DOI 10.1016/j.icrp.2009.05.004
[8]   Use of GAFCHROMIC XR type R films for skin-dose measurements in interventional radiology: Validation of a dosimetric procedure on a sample of patients undergone interventional cardiology [J].
delle Canne, S. ;
Carosi, A. ;
Bufacchi, A. ;
Malatesta, T. ;
Capparella, R. ;
Fragomeni, R. ;
Adorante, N. ;
Bianchi, S. ;
Begnozzi, L. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2006, 22 (03) :105-110
[9]   Comprehensive evaluation of broad-beam transmission of patient supports from three fluoroscopy-guided interventional systems [J].
DeLorenzo, Matthew C. ;
Yang, Kai ;
Li, Xinhua ;
Liu, Bob .
MEDICAL PHYSICS, 2018, 45 (04) :1425-1432
[10]   Characterization of XR-RV3 GafChromic® films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors [J].
Farah, J. ;
Trianni, A. ;
Ciraj-Bjelac, O. ;
Clairand, I. ;
De Angelis, C. ;
Delle Canne, S. ;
Hadid, L. ;
Huet, C. ;
Jarvinen, H. ;
Negri, A. ;
Novak, L. ;
Pinto, M. ;
Siiskonen, T. ;
Waryn, M. J. ;
Knezevic, Z. .
MEDICAL PHYSICS, 2015, 42 (07) :4211-4226