Inhibition effect of zirconium coating on calcium phosphate precipitation of titanium to avoid assimilation with bone

被引:42
作者
Kobayashi, Equo [1 ]
Ando, Miyuki
Tsutsumi, Yusuke
Doi, Hisashi
Yoneyama, Takayuki
Kobayashi, Masahiro
Hanawa, Takao
机构
[1] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Tokyo 1010062, Japan
[2] Chiba Inst Technol, Dept Life & Environm Sci, Narashino, Chiba 2750016, Japan
关键词
biomedical titanium alloys; zirconium coating; surface modification; calcium phosphate; biocompatibility;
D O I
10.2320/matertrans.48.301
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to control of the calcium phosphate precipitation of Ti in body fluid, which might result in assimilated bone re-facture during removal operation of implanted devices such as femoral nails and bone screws after healing, vacuum vapor deposition of Zr on Ti Substrate was carried out. The calcium phosphate precipitation was evaluated through the immersion test into the Hanks' solution. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) were conducted to evaluate inhibition effect of coated Zr layer. Calcium phosphate particle were observed on the Ti with and without 90-mu thick Zr coated layer by SEM. On the other hand, on the specimens with 130-nm thick Zr coated layer and those of Zr sputter-coated, no calcium phosphate particle was observed. By the surface analysis of the specimens Zr sputter-coated, Ca was not identified. It was considered to form zirconium phosphate instead of calcium phosphate by immersion in the Hanks' solution. It was suggested that Zr coating technique can be applied to orthopedic devices to avoid re-fracture of bone by calcium phosphate precipitation during removal operation.
引用
收藏
页码:301 / 306
页数:6
相关论文
共 17 条
  • [1] PRECISELY CONSISTENT ENERGY CALIBRATION METHOD FOR X-RAY PHOTOELECTRON-SPECTROSCOPY
    ASAMI, K
    [J]. JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1976, 9 (06) : 469 - 478
  • [2] XPS DETERMINATION OF COMPOSITIONS OF ALLOY SURFACES AND SURFACE OXIDES ON MECHANICALLY POLISHED IRON-CHROMIUM ALLOYS
    ASAMI, K
    HASHIMOTO, K
    SHIMODAIRA, S
    [J]. CORROSION SCIENCE, 1977, 17 (09) : 713 - 723
  • [3] Morphology and microstructure of electrochemically deposited calcium phosphates in a modified simulated body fluid
    Ban, S
    Maruno, S
    [J]. BIOMATERIALS, 1998, 19 (14) : 1245 - 1253
  • [4] In vitro and in vivo behaviour of Ca- and P-enriched anodized titanium
    Fini, M
    Cigada, A
    Rondelli, G
    Chiesa, R
    Giardino, R
    Giavaresi, G
    Aldini, NN
    Torricelli, P
    Vicentini, B
    [J]. BIOMATERIALS, 1999, 20 (17) : 1587 - 1594
  • [5] Hydrothermal modification of titanium surface in calcium solutions
    Hamada, K
    Kon, M
    Hanawa, T
    Yokoyama, K
    Miyamoto, Y
    Asaoka, K
    [J]. BIOMATERIALS, 2002, 23 (10) : 2265 - 2272
  • [6] COMPOSITIONAL CHANGE IN SURFACE OF TI-ZR ALLOYS IN ARTIFICIAL BIOLIQUID
    HANAWA, T
    OKUNO, O
    HAMANAKA, H
    [J]. JOURNAL OF THE JAPAN INSTITUTE OF METALS, 1992, 56 (10) : 1168 - 1173
  • [7] CALCIUM-PHOSPHATE NATURALLY FORMED ON TITANIUM IN ELECTROLYTE SOLUTION
    HANAWA, T
    OTA, M
    [J]. BIOMATERIALS, 1991, 12 (08) : 767 - 774
  • [8] Hanawa T, 1998, J BIOMED MATER RES, V40, P530, DOI 10.1002/(SICI)1097-4636(19980615)40:4<530::AID-JBM3>3.0.CO
  • [9] 2-G
  • [10] Microdissolution of calcium ions from calcium-ion-implanted titanium
    Hanawa, T
    Asami, K
    Asaoka, K
    [J]. CORROSION SCIENCE, 1996, 38 (09) : 1579 - 1594