Corneal imaging with slit-scanning and Scheimpflug imaging techniques

被引:77
作者
Oliveira, Cristina M. [1 ]
Ribeiro, Celina [1 ]
Franco, Sandra [1 ]
机构
[1] Univ Minho, Ctr Dept Phys, Braga, Portugal
关键词
corneal imaging; keratoconus; keratorefractive surgery; rotating Scheimpflug tomography; slit‐ scanning tomography system; IN-SITU KERATOMILEUSIS; NONCONTACT SPECULAR MICROSCOPY; OPTICAL COHERENCE TOMOGRAPHY; INTRAOCULAR-LENS CALCULATION; LASER REFRACTIVE SURGERY; THICKNESS MEASUREMENTS; ORBSCAN-II; ULTRASOUND PACHYMETRY; KERATOMETRY READINGS; KERATOCONIC EYES;
D O I
10.1111/j.1444-0938.2010.00509.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Modern anterior segment imaging techniques, such as slit-scanning and Scheimpflug imaging, greatly improved the field of corneal imaging. Devices such as the Orbscan (Bausch & Lomb Surgical, Inc) and, more recently, the Pentacam (Oculus, Inc) and the Galilei (Ziemer Ophthalmic Systems AG) have brought a whole new range of clinical possibilities and sparked interest in the academic community. These new tomographers create three-dimensional models of the cornea and enable the direct measurement of both the anterior and posterior surface elevations. In this paper, we present a review of some available literature on those systems, regarding their optical principles and their performance in current clinical applications.
引用
收藏
页码:33 / 42
页数:10
相关论文
共 94 条
[1]   Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry [J].
Al-Mezaine H.S. ;
Al-Amro S.A. ;
Kangave D. ;
Sadaawy A. ;
Wehaib T.A. ;
Al-Obeidan S. .
International Ophthalmology, 2008, 28 (5) :333-338
[2]   Comparison of ultrasonic pachymetry with orbscan in corneal haze [J].
Altan-Yaycioglu, Rana ;
Pelit, Aysel ;
Akova, Yonca Aydin .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (12) :1759-1763
[3]   Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography [J].
Amano, S ;
Honda, N ;
Amano, Y ;
Yamagami, S ;
Miyai, T ;
Samejima, T ;
Ogata, M ;
Miyata, K .
OPHTHALMOLOGY, 2006, 113 (06) :937-941
[4]  
Arntz A, 2003, Arch Soc Esp Oftalmol, V78, P659
[5]   Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis [J].
Baek, TM ;
Lee, KH ;
Kagaya, F ;
Tomidokoro, A ;
Amano, S ;
Oshika, T .
OPHTHALMOLOGY, 2001, 108 (02) :317-320
[6]   Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry [J].
Barkana, Y ;
Gerber, Y ;
Elbaz, U ;
Schwartz, S ;
Ken-Dror, G ;
Avni, I ;
Zadok, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1729-1735
[7]   The reliability of central corneal thickness measurements by ultrasound and by Orbscan system in schoolchildren [J].
Basmak, Hikmet ;
Sahin, Afsun ;
Yildirim, Nilgun .
CURRENT EYE RESEARCH, 2006, 31 (7-8) :569-575
[8]  
Bernilla C, 2009, AM SOC CAT REFR SURG
[9]   Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula [J].
Borasio, Edmondo ;
Stevens, Julian ;
Smith, Guy T. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) :2004-2014
[10]   Accuracy of Orbscan optical pachymetry in corneas with haze [J].
Boscia, F ;
La Tegola, MG ;
Alessio, G ;
Sborgia, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :253-258