Differentiating solitary pulmonary nodules (SPNs) with 3D shape features

被引:0
作者
Wang, Yang [1 ]
McNitt-Gray, Michael F. [1 ]
Brown, Matthew S. [1 ]
Goldin, Jonathan G. [1 ]
Zhao, Haiming [1 ]
Aberle, Denise R. [1 ]
机构
[1] Univ Calif Los Angeles, Dept Radiol, Los Angeles, CA 90066 USA
来源
MEDICAL IMAGING 2007: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2 | 2007年 / 6514卷
关键词
lung cancer; shape index; curvedness; SPN; CT; characterization;
D O I
10.1117/12.713686
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This study developed a methodology to extract the quantitative features of representing nodule 3D shape and investigate the performance of these features in differentiating between benign and malignant solitary pulmonary nodules (SPNs). 36 cases with solitary lung nodules (15 Benign, 21 Malignant) were examined in this study. The CT helical scanning-parameters were <= 3 mm collimation, pitch 1-2, and 1.5-3 min reconstruction interval. The nodule boundaries were contoured by radiologists on 3D volume data. Using these boundaries, the nodule physical 3D surfaces were created and several 3D nodule shape-features were computed, including: Compactness Factor (CF) of nodule, Shape Index (SI) and curvedness of each pixel in the physical 3D nodule surface. The histogram characteristic features of SI and curvedness were calculated. AdaBoost was performed to select the features and their statistically differences were analyzed. Logistic Regression Analysis (LRA) and AdaBoost were used to evaluate the overall diagnostic accuracy. For 36 patients, CF is the first feature selected by AdaBoost, which also has significant difference (t-test, P=0.6 %) between Benign and malignant nodules. However, histogram features of SI and curvedness are not all significantly different. The accuracy of LRA is 75%, with accuracies of AdaBoost using all features is about 80% with cross validation. Generally, SI, curvedness and CF may provide a comprehensive examination of the nodule shape, which can be used in differentiating benign from malignant SPNs. However, other types' features (such as texture, angiogenesis) should be combined with shape information to assist radiologists in characterizing SPNs more accurately.
引用
收藏
页数:8
相关论文
共 28 条
[1]   Automated measurement of single and total lung volume from CT [J].
Brown, MS ;
McNitt-Gray, MF ;
Goldin, JG ;
Greaser, LE ;
Hayward, UM ;
Sayre, JW ;
Arid, MK ;
Aberle, DR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (04) :632-640
[2]  
Cardinale Luciano, 2005, Radiol Med, V110, P532
[3]  
CHIN AY, 2004, RADIOLOGY, P191
[4]   Shape analysis of pulmonary nodules based on thin section CT images [J].
Kawata, Y ;
Niki, N ;
Ohmatsu, H ;
Eguchi, K ;
Moriyama, N .
IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 :964-974
[5]  
KOENDERINK J, 1992, IMAGE VISION COMPUTI, V10
[6]   A pattern classification approach to characterizing solitary pulmonary nodules imaged on high resolution CT: Preliminary results [J].
McNitt-Gray, MF ;
Har, EM ;
Wyckoff, N ;
Sayre, JW ;
Goldin, JG ;
Aberle, DR .
MEDICAL PHYSICS, 1999, 26 (06) :880-888
[7]   Application of CT in the investigation of angiogenesis in oncology [J].
Miles, KA ;
Charnsangavej, C ;
Lee, FT ;
Fishman, EK ;
Horton, K ;
Lee, TY .
ACADEMIC RADIOLOGY, 2000, 7 (10) :840-850
[8]   Perfusion CT for the assessment of tumour vascularity: which protocol? [J].
Miles, KA .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 :S36-S42
[9]   Perfusion CT: a worthwhile enhancement? [J].
Miles, KA ;
Griffiths, MR .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (904) :220-231
[10]   Standardized perfusion value: Universal CT contrast enhancement scale that correlates with FDG PET in lung nodules [J].
Miles, KA ;
Griffiths, MR ;
Fuentes, MA .
RADIOLOGY, 2001, 220 (02) :548-553