Behavior of Nickel-Titanium Instruments Manufactured with Different Thermal Treatments

被引:52
|
作者
Joviano Pereira, Erika Sales [1 ]
Diniz Viana, Ana Cecilia [1 ]
Lopes Buono, Vicente Tadeu [2 ]
Peters, Ove A. [3 ]
de Azevedo Bahia, Maria Guiomar [1 ]
机构
[1] Univ Fed Minas Gerais, Fac Dent, Dept Restorat Dent, BR-31270901 Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais, Sch Engn, Dept Met & Mat Engn, BR-31270901 Belo Horizonte, MG, Brazil
[3] Univ Pacific, Arthur A Dugoni Sch Dent, Dept Endodont, San Francisco, CA USA
关键词
CM technology; controlled memory technology; flexibility; M-Wire; nickel-titanium endodontic instruments; torque; Vortex Blue; ROTARY ENDODONTIC INSTRUMENTS; CYCLIC FATIGUE RESISTANCE; MECHANICAL-PROPERTIES; CONTROLLED MEMORY; SHAPE-MEMORY; IN-VITRO; TORSIONAL STRESS; PROFILE GT; M-WIRE; FILES;
D O I
10.1016/j.joen.2014.06.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to investigate if nickel-titanium instruments with similar designs manufactured by different thermal treatments would exhibit significantly different in vitro behavior. Methods: Thirty-six instruments each of ProTaper Universal (PTU F1; Dentsply Maillefer, Ballaigues, Switzerland), ProFile Vortex (PV; Dentsply Tulsa Dental Specialties, Tulsa, OK), Vortex Blue (VB, Dentsply Tulsa Dental Specialties), and TYPHOON Infinite Flex NiTi (TYP; Clinician's Choice Dental Products, New Milford, CT) (all size 25/.06) were evaluated. Bending resistance, torsion at failure, and dynamic torsional tests were performed with the instruments (n = 12). Analysis of variance and Tukey post hoc tests were applied. Results: Flexibility was significantly higher for TYP compared with the other 3 groups (P < .0001). With respect to the maximum torque at failure, PV group showed the highest resistance to twisting (torsional strength) among the analyzed instruments followed by VB, TYP, and PTU. The TYP group exhibited greater angular deflection at failure compared with the other groups (P < .0001). The mean dynamic torque scores during simulated canal preparation were highest for TYP (3.01 +/- 0.71 Ncm) and lowest for PV (1.62 +/- 0.79 Ncm). However, no significant differences were observed comparing groups PTU with TYP and VB and VB with PV (P > .05). The highest mean forces were recorded with PTU (7.02 +/- 2.36 N) and the lowest with TYP (1.22 +/- 0.40 N). Conclusions: TYP instruments were significantly more flexible than the other instruments tested. The PV group had the highest torsional strength and TYP, despite being the most flexible, showed similar torsional moments to the other instruments, whereas its angular deflection was the highest among the groups.
引用
收藏
页码:67 / 71
页数:5
相关论文
共 50 条
  • [1] Impact of Heat Treatments on the Fatigue Resistance of Different Rotary Nickel-titanium Instruments
    Moreira Braga, Ligia Carolina
    Faria Silva, Ana Cristina
    Lopes Buono, Vicente Tadeu
    de Azevedo Bahia, Maria Guiomar
    JOURNAL OF ENDODONTICS, 2014, 40 (09) : 1494 - 1497
  • [2] Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study
    Plotino, Gianluca
    Testarelli, Luca
    Al-Sudani, Dina
    Pongione, Gianlcarlo
    Grande, Nicola M.
    Gambarini, Gianluca
    ODONTOLOGY, 2014, 102 (01) : 31 - 35
  • [3] Influence of Different Manufacturing Methods on the Mechanical Behavior of Nickel-Titanium Endodontic Instruments
    Lopes, Helio Pereira
    Queiroz de Carvalho, Bianca Correia
    de Gois, Robson Bezerra
    de Azevedo Jacinto Inojosa, Ines de Ftima
    Elias, Carlos Nelson
    Leal Vieira, Victor Talarico
    de Souza, Leticia Chaves
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2013, 13 (02): : 183 - 188
  • [4] Corrosion of nickel-titanium instruments
    Sonntag, David
    Heithecker, Karolin
    ENDO-ENDODONTIC PRACTICE TODAY, 2008, 2 (03): : 185 - 191
  • [5] Evaluation of the mechanical properties of different nickel-titanium retreatment instruments
    Weissheimer, Theodoro
    Heck, Luana
    Calefi, Pedro Henrique Souza
    Alcalde, Murilo Priori
    da Rosa, Ricardo Abreu
    Vivan, Rodrigo Ricci
    Duarte, Marco Antonio Hungaro
    So, Marcus Vinicius Reis
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (02) : 265 - 272
  • [6] Cyclic fatigue of different nickel-titanium endodontic rotary instruments
    Tripi, Teresa Roberta
    Bonaccorso, Antonio
    Condorelli, Guglielmo Guido
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 102 (04): : E106 - E114
  • [7] Retreatment with Nickel-Titanium Rotary Instruments
    Yilmaz, Ayca
    Yigit, Dilek Helvacioglu
    JOURNAL OF ISTANBUL UNIVERSITY FACULTY OF DENTISTRY, 2014, 48 (01) : 71 - 78
  • [8] Comparing apical preparations of root canals shaped by nickel-titanium rotary instruments and nickel-titanium hand instruments
    Deplazes, P
    Peters, O
    Barbakow, F
    JOURNAL OF ENDODONTICS, 2001, 27 (03) : 196 - 202
  • [9] Torsional fatigue resistance of pathfinding instruments manufactured from several nickel-titanium alloys
    Alcalde, M. P.
    Duarte, M. A. H.
    Bramante, C. M.
    Tanomaru-filho, M.
    Vasconcelos, B. C.
    So, M. V. R.
    Vivan, R. R.
    INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (06) : 697 - 704
  • [10] Cutting efficiency of five different types of rotary nickel-titanium instruments
    Schaefer, Edgar
    Oitzinger, Mirjam
    JOURNAL OF ENDODONTICS, 2008, 34 (02) : 198 - 200