Flow-injection determination of total iron in freshwater samples with neutralisation chemiluminescence

被引:7
作者
Attiq-ur-Rehman [1 ]
Yaqoob, Mohammad [1 ]
Waseem, Amir [1 ]
Nabi, Abdul [1 ]
机构
[1] Univ Balochistan, Dept Chem, Quetta, Pakistan
关键词
flow-injection analysis; chemiluminescence; neutralisation reaction; iron; freshwater samples; SPECTROPHOTOMETRIC DETERMINATION; SELECTIVE DETERMINATION; POTASSIUM HYDROXIDE; NITRIC-ACID; SEAWATER; IRON(III); ION; PRECONCENTRATION; CHROMATOGRAPHY; MICROCOLUMN;
D O I
10.1080/03067310902960985
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection chemiluminescence method has been established for the determination of total iron in freshwater samples. The enhanced chemiluminescence emission was caused by the iron(II) from the neutralisation reaction of hydrochloric acid and sodium hydroxide without the use of any chemiluminescent reagent. The calibration graph was linear in the concentration range of 2.8-560 mu g L-1 (r2 = 0.9983, n = 8), with relative standard deviation (RSD; n = 4) in the range of 0.8-2.6%. The limit of detection (S/N = 3) was 0.56 mu g L-1 with injection throughput of 180 h-1. The effect of common anions and cations were studied over their environmentally relevant concentrations in freshwaters. The method was successfully applied to determine total iron in freshwater samples. Iron(III) was reduced to iron(II) by using hydroxylammonium chloride. The proposed method was compared with spectrophotometric method and there was no significant difference between the two methods at the 95% confidence level (t-test). Analysis of river water (certified reference material SLRS-4) for iron(II), after reduction of iron(III) with hydroxylammonium chloride, gave good results (2.17 +/- 0.22 mu M compared with the certificate value of 1.85 +/- 0.1 mu M).
引用
收藏
页码:1071 / 1080
页数:10
相关论文
共 50 条
  • [21] Highly sensitive flow-injection chemiluminescence determination of pyrogallol compounds
    Kanwal, Shamsa
    Fu, Xiaohong
    Su, Xingguang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2009, 74 (05) : 1046 - 1049
  • [22] Flow-injection chemiluminescence determination of fluoroquinolones by enhancement of weak chemiluminescence from peroxynitrous acid
    Liang, YD
    Song, JF
    Yang, XF
    ANALYTICA CHIMICA ACTA, 2004, 510 (01) : 21 - 28
  • [23] FLOW-INJECTION DETERMINATION OF ETHANOL BY FIBEROPTIC CHEMILUMINESCENCE MEASUREMENT
    XIE, XF
    SULEIMAN, AA
    GUILBAULT, GG
    YANG, ZM
    SUN, ZA
    ANALYTICA CHIMICA ACTA, 1992, 266 (02) : 325 - 329
  • [24] DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE BY FLOW-INJECTION CHEMILUMINESCENCE METHOD
    唐玉海
    韩小年
    于春玲
    孙媛媛
    姚宏
    Academic Journal of Xi'an Jiaotong University, 2006, (02) : 136 - 138
  • [25] A novel flow-injection chemiluminescence system for the determination of guanine
    Yang, M
    Liu, R
    Hou, DY
    Guo, YY
    LUMINESCENCE, 2005, 20 (4-5) : 307 - 310
  • [26] Determination of ofloxacin using a chemiluminescence flow-injection method
    Rao, Y
    Tong, Y
    Zhang, XR
    Luo, G
    Baeyens, WRG
    ANALYTICA CHIMICA ACTA, 2000, 416 (02) : 227 - 230
  • [27] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF THE HYDRAZONES OF AROMATIC KETONES
    AHMED, TEA
    TOWNSHEND, A
    ANALYTICA CHIMICA ACTA, 1994, 292 (1-2) : 169 - 174
  • [28] Determination of Three Imidazole Derivatives by Flow-Injection Chemiluminescence
    Sun, Sijuan
    Tang, Yuhai
    Fu, Qiang
    Chen, Jine
    Zhang, Guangbin
    ANALYTICAL LETTERS, 2009, 42 (12) : 1868 - 1881
  • [29] Flow-Injection Chemiluminescence Determination of Cobalt(II) with Umbelliferon
    Watanabe, Kunihiro
    Onishi, Haruka
    Shitanda, Isao
    Itagaki, Masayuki
    BUNSEKI KAGAKU, 2009, 58 (06) : 531 - 537
  • [30] Flow-injection chemiluminescence method for the determination of hydrocortisone and progesterone
    Li, HN
    Ci, YX
    APPLIED SPECTROSCOPY, 1997, 51 (10) : 1484 - 1487