In vivo monitoring of function of autologous engineered pulmonary valve

被引:116
作者
Gottlieb, Danielle [1 ,2 ,3 ]
Kunal, Tandon [1 ]
Emani, Sitaram [1 ]
Aikawa, Elena [2 ,3 ]
Brown, David W. [1 ]
Powell, Andrew J. [1 ]
Nedder, Arthur [1 ]
Engelmayr, George C., Jr. [4 ]
Melero-Martin, Juan M. [1 ]
Sacks, Michael S. [5 ]
Mayer, John E., Jr. [1 ]
机构
[1] Childrens Hosp, Boston, MA 02115 USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Boston, MA 02114 USA
[4] MIT, Boston, MA USA
[5] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
基金
美国国家卫生研究院;
关键词
BONE-MARROW; HEART-VALVE; STEM-CELLS;
D O I
10.1016/j.jtcvs.2009.11.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Clinical translation of tissue-engineered heart valves requires valve competency and lack of stenosis in the short and long term. Early studies of engineered valves showed promise, although lacked complete definition of valve function. Building on prior experiments, we sought to define the in vivo changes in structure and function of autologous engineered pulmonary valved conduits. Methods: Mesenchymal stem cells were isolated from neonatal sheep bone marrow and seeded onto a bioresorbable scaffold. After 4 weeks of culture, valved conduits were implanted. Valve function, cusp, and conduit dimensions were evaluated at implantation (echocardiography), at the experimental midpoint (magnetic resonance imaging), and at explant, at 1 day, and 1, 6, 12, or 20 weeks postoperatively (direct measurement, echocardiography). Histologic evaluation was performed. Results: Nineteen animals underwent autologous tissue-engineered valved conduit replacement. At implantation, valved conduit function was excellent; maximum transvalvular pressure gradient by Doppler echocardiography was 17 mm Hg; most valved conduits showed trivial pulmonary regurgitation. At 6 postoperative weeks, valve cusps appeared less mobile; pulmonary regurgitation was mild to moderate. At 12 weeks or more, valved conduit cusps were increasingly attenuated and regurgitant. Valved conduit diameter remained unchanged over 20 weeks. Dimensional measurements by magnetic resonance imaging correlated with direct measurement at explant. Conclusions: We demonstrate autologous engineered tissue valved conduits that function well at implantation, with subsequent monitoring of dimensions and function in real time by magnetic resonance imaging. In vivo valves undergo structural and functional remodeling without stenosis, but with worsening pulmonary regurgitation after 6 weeks. Insights into mechanisms of in vivo remodeling are valuable for future iterations of engineered heart valves. (J Thorac Cardiovasc Surg 2010; 139: 723-31)
引用
收藏
页码:723 / 731
页数:9
相关论文
共 20 条
[1]   Heart valve development - Endothelial cell signaling and differentiation [J].
Armstrong, EJ ;
Bischoff, J .
CIRCULATION RESEARCH, 2004, 95 (05) :459-470
[2]   ROCK controls matrix synthesis in vascular smooth muscle cells - Coupling vasoconstriction to vascular remodeling [J].
Chapados, Rene ;
Abe, Khotaro ;
Ihida-Stansbury, Kaori ;
McKean, David ;
Gates, Adam T. ;
Kern, Michael ;
Merklinger, Sandra ;
Elliott, John ;
Plant, Anne ;
Shimokawa, Hiroaki ;
Jones, Peter Lloyd .
CIRCULATION RESEARCH, 2006, 99 (08) :837-844
[3]   Rapid expansion of recycling stem cells in cultures of plastic-adherent cells from human bone marrow [J].
Colter, DC ;
Class, R ;
DiGirolamo, CM ;
Prockop, DJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (07) :3213-3218
[4]  
Flanagan TC, 2009, TISSUE ENG PT A, V15, P2965, DOI [10.1089/ten.tea.2009.0018, 10.1089/ten.TEA.2009.0018]
[5]  
GOTTLIEB D, MULTIAXIAL TENSION A
[6]   Functional growth in tissue-engineered living, vascular grafts -: Follow-up at 100 weeks in a large animal model [J].
Hoerstrup, Simon P. ;
Cummings, Ian ;
Lachat, Mario ;
Schoen, Frederick J. ;
Jenni, Rolf ;
Leschka, Sebastian ;
Neuenschwander, Stefan ;
Schmidt, Dorthe ;
Mol, Anita ;
Guenter, Christina ;
Goessi, Mathias ;
Genoni, Michele ;
Zund, Gregor .
CIRCULATION, 2006, 114 :I159-I166
[7]  
HOERSTRUP SP, 2000, CIRCULATION S3, V44, P102
[8]   Decellularization reduces calcification while improving both durability and 1-year functional results of pulmonary homograft valves in juvenile sheep [J].
Hopkins, Richard A. ;
Jones, Alyce Linthurst ;
Wolfinbarger, Lloyd ;
Moore, Mark A. ;
Bert, Arthur A. ;
Lofland, Gary K. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (04) :907-U142
[9]   Tissue engineering of viable pulmonary arteries for surgical correction of congenital heart defects [J].
Leyh, RG ;
Wilhelmi, M ;
Rebe, P ;
Ciboutari, S ;
Haverich, A ;
Mertsching, H .
ANNALS OF THORACIC SURGERY, 2006, 81 (04) :1466-1471
[10]   Hearts and bones: Shared regulatory mechanisms in heart valve, cartilage, tendon, and bone development [J].
Lincoln, Joy ;
Lange, Alexander W. ;
Yutzey, Katherine E. .
DEVELOPMENTAL BIOLOGY, 2006, 294 (02) :292-302