摘要
Treatment of complex aneurysms using microsurgical and other conventional neuroendovascular techniques remains challenging. As a result, stent- and balloon-assisted coiling are instead performed to treat morphologically complex aneurysms, which include giant, wide-necked, and fusiform aneurysms. While these techniques have had success in treating these complex aneurysms, recanalization rates associated with these techniques are still problematic. In the constant effort to improve the outcome of complex aneurysm treatment, flow-diverting stents (FDSs) have emerged in recent years as the preferred treatment. Instead of directly obstructing the flow of blood into the aneurysmal sac, as is the case for stent- and balloon-assisted coiling, FDSs are placed in the parent blood vessel to divert blood flow away from the aneurysm itself. Subsequent to the diverting away of blood from the aneurysm, a thrombotic cascade ensues that ultimately results in the closure of the aneurysm while the parent vessel's perforators are preserved. Current known risks for this procedure include vessel rupture or perforation, in-stent thrombosis, perforator occlusion, procedural or delayed hemorrhages, and perianeurysmal edema. In this review, we will evaluate the mechanisms of actions, clinical applications, complications, and ongoing studies for FDSs.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 50 条
  • [31] Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment
    Kulcsar, Z.
    Houdart, E.
    Bonafe, A.
    Parker, G.
    Millar, J.
    Goddard, A. J. P.
    Renowden, S.
    Gal, G.
    Turowski, B.
    Mitchell, K.
    Gray, F.
    Rodriguez, M.
    van den Berg, R.
    Gruber, A.
    Desal, H.
    Wanke, I.
    Ruefenacht, D. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) : 20 - 25
  • [32] The off-label uses of pipeline embolization device for complex cerebral aneurysms: Mid-term follow-up in a single center
    Zhang, Huachen
    Ren, Jiyang
    Wang, Jiangdian
    Lv, Xianli
    INTERVENTIONAL NEURORADIOLOGY, 2025, 31 (02) : 158 - 167
  • [33] Evolution of intracranial aneurysm treatment: From Hunterian ligation to the flow diverter
    Wong, George K. C.
    Tan, Hai-Bin
    Kwan, Marco C. L.
    Ng, Rebecca Y. T.
    Yu, Simon C. H.
    Zhu, Xian-Lun
    Poon, Wai-Sang
    SURGICAL PRACTICE, 2011, 15 (01) : 16 - 20
  • [34] Coiling as a Rescue Strategy for Flow Diverter Prolapse into a Giant Intracranial Aneurysm
    Ferrigno, Ana S.
    Caro-Osorio, Enrique
    Martinez, Hector R.
    Martinez-Ordaz, Lourdes
    Figueroa-Sanchez, Jose A.
    WORLD NEUROSURGERY, 2020, 133 : 392 - 397
  • [35] Intracranial Aneurysms in Children: The Role of Stenting and Flow-Diversion
    Vargas, Sergio A.
    Diaz, Carlos
    Herrera, Diego A.
    Dublin, Arthur B.
    JOURNAL OF NEUROIMAGING, 2016, 26 (01) : 41 - 45
  • [36] Comparison of Flow Diversion and Coiling for the Treatment of Unruptured Intracranial Aneurysms
    Xin, Wen-qiang
    Xin, Qi-qiang
    Yuan, Yan
    Chen, Shi
    Gao, Xiang-liang
    Zhao, Yan
    Zhang, Hao
    Li, Wen-kui
    Yang, Xin-yu
    WORLD NEUROSURGERY, 2019, 128 : 464 - 472
  • [37] Microsurgical Management of Intracranial Aneurysms After Flow Diversion Failure
    Grasso, Giovanni
    Torregrossa, Fabio
    WORLD NEUROSURGERY, 2020, 133 : 245 - 247
  • [38] Microsurgical Management of Intracranial Aneurysms After Failed Flow Diversion
    Mbabuike, Nnenna
    Shakur, Sophia F.
    Gassie, Kelly
    Srinivasan, Visish
    Mascitelli, Justin
    Abla, Adib
    Duckworth, Edward
    Kan, Peter
    Zenonos, Georgios A.
    Schirmer, Clemens
    Charbel, Fady T.
    de Olivera, Evandro
    Morcos, Jacques J.
    Lawton, Michael
    Tawk, Rabih G.
    WORLD NEUROSURGERY, 2020, 134 : E16 - E28
  • [39] Simple Measurement of Aneurysm Residual after Treatment: the SMART scale for evaluation of intracranial aneurysms treated with flow diverters
    Grunwald, Iris Quasar
    Kamran, M.
    Corkill, R. A.
    Kuehn, A. L.
    Choi, I. S.
    Turnbull, S.
    Dobson, D.
    Fassbender, K.
    Watson, D.
    Gounis, M. J.
    ACTA NEUROCHIRURGICA, 2012, 154 (01) : 21 - 26
  • [40] Resolution of Mass Effect and Compression Symptoms following Endoluminal Flow Diversion for the Treatment of Intracranial Aneurysms
    Szikora, I.
    Marosfoi, M.
    Salomvary, B.
    Berentei, Z.
    Gubucz, I.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (05) : 935 - 939