Intravascular Functional Maps of Common Neurovascular Lesions Derived From Volumetric 4D CT Data

被引:9
作者
Barfett, Joe J. [1 ]
Fierstra, Jorn [1 ,2 ]
Willems, Peter W. A. [1 ]
Mikulis, David J. [1 ]
Krings, Timo [1 ]
机构
[1] Univ Hlth Network, Toronto Western Hosp, Div Neuroradiol, Dept Med Imaging, Toronto, ON M5T 2S8, Canada
[2] Univ Hlth Network, Toronto Western Hosp, Dept Neurosurg, Toronto, ON M5T 2S8, Canada
关键词
volumetric CT; MTT; TTP; intravascular; segmentation; ANGIOGRAPHY; TIME;
D O I
10.1097/RLI.0b013e3181e1939d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Current computed tomography angiography (CTA) postprocessing tools do not support quantitative assessment of intravascular physiology. Dynamic volumetric CT, acquired at a sufficiently high temporal resolution, is ideal for such analysis. Following preliminary experiments in flow phantoms, we examine the segmentation of blood vessels from 4D CT angiography by curve fit and encoding of functional blood flow information into the resulting functional intravascular maps. Materials and Methods: Flow phantoms were constructed consisting of a single pipe input and 4 simultaneous outputs of varying flow rates. Two outflow pipe diameters were tested. Bolus transit time (TT), time to peak (TTP), and time of arrival (TOA) were analyzed using contrast bolus profiles generated from 4D volumetric CT examinations on a 320 detector scanner in regions of interest placed 10 cm apart in all outflow pipes. Six subjects with various neurovascular lesions were next examined using a volumetric contrast- enhanced 4D CT angiography protocol. Segmentation was performed by quadratic curve fit after comparative analysis and optimization of the segmentation technique using quadratic curves, the gamma variate function, and a simplified formulation of the gamma variate function. After segmentation, quantitative analysis of spatially congruent intravascular voxels including TTP, rise, TT, and slope of the contrast upstroke was employed to encode physiologic information into the segmentations and produce intravascular functional maps. Comparison was made in each case to the patient's routine imaging. Results: Increasing volumetric flow rates correspond to reduction of bolus TT in flow phantoms. TT elongation was observed as the contrast bolus moved distally in all pipes, with greater elongation seen at slower flow rates and larger pipe diameters. A greater difference was observed between TTP proximally and distally in pipes compared with TOA, an effect most prominent at slower flow rates and larger pipe lumens, and thus TTP was chosen for functional encoding into segmentations of the clinical series. In vivo, the quadratic function demonstrated the lowest coefficient of variation when fit to intravascular time density series and outperformed 2 formulations of the gamma variate function. After segmentation with quadratic curves, Gaussian distributions were chosen over gamma variate functions to characterize contrast bolus profiles while neglecting recirculation and to calculate functional parameters for spatial encoding. Intravascular functional maps free of bone artifacts were created in every case that demonstrated all appropriate vessels and showed agreement with conventional imaging modalities in terms of vessel delineation and the diagnosis of vascular pathology. The most useful and interesting functional maps are discussed in each case. Conclusions: The above approach to quantitative CT angiography provides a method of evaluating dynamic CTA data by means of intravascular functional maps. The techniques are broadly applicable in the clinical assessment of a variety of vascular diseases.
引用
收藏
页码:370 / 377
页数:8
相关论文
共 19 条
  • [1] Dynamic 320-Section CT Angiography in Cranial Arteriovenous Shunting Lesions
    Brouwer, P. A.
    Bosman, T.
    van Walderveen, M. A. A.
    Krings, T.
    Leroux, A. A.
    Willems, P. W. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (04) : 767 - 770
  • [2] Functional imaging in CT
    Dawson, Peter
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 331 - 340
  • [3] Definitive reconstruction of circumferential fusiform intracranial aneurysms with the pipeline embolization device
    Fiorella, David
    Woo, Henry H.
    Albuquerque, Felipe C.
    Nelson, Peter K.
    [J]. NEUROSURGERY, 2008, 62 (05) : 1115 - 1120
  • [4] Cerebral perfusion CT: Technique and clinical applications
    Hoeffner, EG
    Case, I
    Jain, R
    Gujar, SK
    Shah, GV
    Deveikis, JP
    Carlos, RC
    Thompson, BG
    Harrigan, MR
    Mukherji, SK
    [J]. RADIOLOGY, 2004, 231 (03) : 632 - 644
  • [5] Endovascular management of dural arteriovenous fistulas of the transverse and sigmoid sinus in 150 patients
    Kirsch, M.
    Liebig, T.
    Kuehne, D.
    Henkes, H.
    [J]. NEURORADIOLOGY, 2009, 51 (07) : 477 - 483
  • [6] 4-D Imaging in Cerebrovascular Disorders by Using 320-Slice CT: Feasibility and Preliminary Clinical Experience
    Klingebiel, Randolf
    Siebert, Eberhard
    Diekmann, Susanne
    Wiener, Edzard
    Masuhr, Florian
    Wagner, Moritz
    Bauknecht, Hans-Christian
    Dewey, Marc
    Bohner, G.
    [J]. ACADEMIC RADIOLOGY, 2009, 16 (02) : 123 - 129
  • [7] Lee T.-Y., 2007, Multidetector Computed Tomography in Cerebrovascular Disease: CT Perfusion Imaging, V1st, P13
  • [8] A SIMPLIFIED FORMULATION OF THE GAMMA VARIATE FUNCTION
    MADSEN, MT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (07) : 1597 - 1600
  • [9] Matsumoto M, 2007, AM J NEURORADIOL, V28, P299
  • [10] Perfusion CT: a worthwhile enhancement?
    Miles, KA
    Griffiths, MR
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (904) : 220 - 231