Reduction of the scanning time by total variation minimization reconstruction for X-ray tomography in a SEM

被引:5
|
作者
Laloum, D. [1 ,2 ,3 ]
Printemps, T. [1 ,2 ]
Sanchez, D. F. [1 ,2 ]
Lorut, F. [3 ]
Audoit, G. [1 ,2 ]
Bleuet, P. [1 ,2 ]
机构
[1] Univ Grenoble Alpes, Grenoble, France
[2] CEA, LETI, F-38054 Grenoble 9, France
[3] STMicroelectronics, Crolles, France
关键词
Copper pillar; tomography; TSV; X-ray; total variation minimization; 3D integration; SENSING-ELECTRON TOMOGRAPHY; MICROTOMOGRAPHY;
D O I
10.1111/jmi.12162
中图分类号
TH742 [显微镜];
学科分类号
摘要
Total variation minimization is applied to the particular case of X-ray tomography in a scanning electron microscope. To prove the efficiency of this reconstruction method, noise-free and noisy data based on the Shepp & Logan phantom have been simulated. These simulations confirm that Total variation minimization-reconstruction algorithm better manages data containing low number of projections with respect to simultaneous iterative reconstruction technique or filtered backprojection, even in the presence of noise. The algorithm has been applied to real data sets, with a low angular sampling and a high level of noise. Two samples containing micro-interconnections have been analyzed and 3D reconstructions show that Total variation minimization-based algorithm performs well even with 60 projections in order to properly recover a 500 nm diameter void inside a copper interconnection.
引用
收藏
页码:90 / 99
页数:10
相关论文
共 50 条
  • [1] Electron tomography based on a total variation minimization reconstruction technique
    Goris, B.
    Van den Broek, W.
    Batenburg, K. J.
    Mezerji, H. Heidari
    Bals, S.
    ULTRAMICROSCOPY, 2012, 113 : 120 - 130
  • [2] Deep sub micrometer imaging of defects in copper pillars by X-ray tomography in a SEM
    Laloum, D.
    Lorut, F.
    Bertheau, J.
    Audoit, G.
    Bleuet, P.
    MICRON, 2014, 58 : 1 - 8
  • [3] X-ray nanotomography in a SEM
    Pauwels, Bart
    Liu, Xuan
    Sasov, Alexander
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [4] Total Variation (TV) l1 Norm Minimization Based Limited Data X-ray CT Image Reconstruction
    Sarkar, Shubhabrata
    Wahi, Pankaj
    Munshi, Prabhat
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 2020, 31 (03) : 164 - 186
  • [5] Iterative X-ray cone-beam tomography for metal artifact reduction and local region reconstruction
    Wang, G
    Vannier, MW
    Cheng, PC
    MICROSCOPY AND MICROANALYSIS, 1999, 5 (01) : 58 - 65
  • [6] A new scanning technique for X-ray computed tomography
    Nukaga, Jun
    Kitazawa, So
    Kamimura, Hiroshi
    NDT & E INTERNATIONAL, 2008, 41 (07) : 564 - 569
  • [7] Limited data image reconstruction in optoacoustic tomography by constrained, total variation minimization
    Wang, Kun
    Sidky, Emil Y.
    Anastasio, Mark A.
    Oraevsky, Alexander A.
    Pan, Xiaochuan
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2011, 2011, 7899
  • [8] Phase retrieval in in-line x-ray phase contrast imaging based on total variation minimization
    Kostenko, Alexander
    Batenburg, K. Joost
    Suhonen, Heikki
    Offerman, S. Erik
    van Vliet, Lucas J.
    OPTICS EXPRESS, 2013, 21 (01): : 710 - 723
  • [9] X-ray scattering tomography
    Gorshkov, V. A.
    Kroening, M.
    Anosov, Y. V.
    Dorjgochoo, O.
    NONDESTRUCTIVE TESTING AND EVALUATION, 2005, 20 (03) : 147 - 157
  • [10] Sparse-view x-ray CT reconstruction via total generalized variation regularization
    Niu, Shanzhou
    Gao, Yang
    Bian, Zhaoying
    Huang, Jing
    Chen, Wufan
    Yu, Gaohang
    Liang, Zhengrong
    Ma, Jianhua
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (12) : 2997 - 3017