A critical appraisal of the quality of adult dual-energy X-ray absorptiometry guidelines in osteoporosis using the AGREE II tool: An EuroAIM initiative

被引:24
|
作者
Messina, Carmelo [1 ]
Bignotti, Bianca [2 ]
Bazzocchi, Alberto [3 ]
Phan, Catherine M. [4 ]
Tagliafico, Alberto [5 ,6 ]
Guglielmi, Giuseppe [7 ]
Sardanelli, Francesco [8 ,9 ]
Sconfienza, Luca Maria [9 ,10 ]
机构
[1] Univ Milan, Scuola Specializzaz Radiodiagnost, Via Festa Perdono 7, I-20122 Milan, Italy
[2] Univ Genoa, Dept Hlth Sci, Genoa, Italy
[3] Rizzoli Orthopaed Inst, Diagnost & Intervent Radiol, Via GC Pupilli 1, I-40136 Bologna, Italy
[4] St Antoine Hosp, Dept Radiol, Paris, France
[5] Univ Genoa, Genoa, Italy
[6] AOU IRCCS San Martino IST, Genoa, Italy
[7] Univ Foggia, Dept Radiol, Foggia, Italy
[8] IRCCS Policlin San Donato, Serv Radiol, Piazza Malan 1, I-20097 San Donato Milanese, Italy
[9] Univ Milan, Dipartimento Sci Biomed Salute, Via Pascal 36, I-20133 Milan, Italy
[10] IRCCS Ist Ortoped Galeazzi, Unita Operat Radiol Diagnost & Interventist, Via Riccardo Galeazzi 4, I-20161 Milan, Italy
来源
INSIGHTS INTO IMAGING | 2017年 / 8卷 / 03期
关键词
Dual-energyX-ray absorptiometry; DXA; Guidelines; Agree; Evidence based medicine; CLINICAL-PRACTICE GUIDELINES; RECOMMENDATIONS; PREVALENCE; CANADA;
D O I
10.1007/s13244-017-0553-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Dual energy X-ray absorptiometry (DXA) is the most widely used technique to measure bone mineral density (BMD). Appropriate and accurate use of DXA is of great importance, and several guidelines have been developed in the last years. Our aim was to evaluate the quality of published guidelines on DXA for adults. Methods Between June and July 2016 we conducted an online search for DXA guidelines, which were evaluated by four independent readers blinded to each other using the AGREE II instrument. A fifth independent reviewer calculated scores per each domain and agreement between reviewers' scores. Results Four out of 59 guidelines met inclusion criteria and were included. They were published between 2005 and 2014. Three out of four guidelines reached a high level of quality, having at least five domain scores higher than 60%. Domain 1 (Scope and Purpose) achieved the highest result (total score = 86.8 +/- 3.7%). Domain 6 (Editorial Independence) had the lowest score (total score = 54.7 +/- 12.5%). Interobserver agreement ranged from fair (0.230) to good (0.702). Conclusions Overall, the quality of DXA guidelines is satisfactory when evaluated using the AGREE II instrument. The Editorial Independence domain was the most critical, thus deserving more attention when developing future guidelines. Main messages Three of four guidelines on DXA had a high quality level (> 60%). Scope/purpose had the highest score (86.8 +/- 3.7%). Editorial Independence had the lowest score (54.7 +/- 12.5%). Interobserver agreement ranged from fair (0.230) to good (0.702).
引用
收藏
页码:311 / 317
页数:7
相关论文
共 50 条
  • [41] USE OF DUAL-ENERGY X-RAY ABSORPTIOMETRY IN OBESE INDIVIDUALS
    TATARANNI, PA
    RAVUSSIN, E
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 62 (04) : 730 - 734
  • [42] Prevalence and type of errors in dual-energy x-ray absorptiometry
    Carmelo Messina
    Michele Bandirali
    Luca Maria Sconfienza
    Nathascja Katia D’Alonzo
    Giovanni Di Leo
    Giacomo Davide Edoardo Papini
    Fabio Massimo Ulivieri
    Francesco Sardanelli
    European Radiology, 2015, 25 : 1504 - 1511
  • [43] PRECISION AND STABILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENTS
    JOHNSON, J
    DAWSONHUGHES, B
    CALCIFIED TISSUE INTERNATIONAL, 1991, 49 (03) : 174 - 178
  • [44] Dual-energy X-ray absorptiometry pitfalls in Thalassemia Major
    Pellegrino, Fabio
    Zatelli, Maria Chiara
    Bondanelli, Marta
    Carnevale, Aldo
    Cittanti, Corrado
    Fortini, Monica
    Gamberini, Maria Rita
    Giganti, Melchiore
    Ambrosio, Maria Rosaria
    ENDOCRINE, 2019, 65 (03) : 469 - 482
  • [45] Abdominal Fat Assessment in Adolescents Using Dual-energy X-ray Absorptiometry
    Tsang, Tracey W.
    Briody, Julie
    Kohn, Michael
    Chow, Chin Moi
    Singh, Maria Fiatarone
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2009, 22 (09) : 781 - 794
  • [46] Dual-energy X-ray absorptiometry pitfalls in Thalassemia Major
    Fabio Pellegrino
    Maria Chiara Zatelli
    Marta Bondanelli
    Aldo Carnevale
    Corrado Cittanti
    Monica Fortini
    Maria Rita Gamberini
    Melchiore Giganti
    Maria Rosaria Ambrosio
    Endocrine, 2019, 65 : 469 - 482
  • [47] Prevalence and type of errors in dual-energy x-ray absorptiometry
    Messina, Carmelo
    Bandirali, Michele
    Sconfienza, Luca Maria
    D'Alonzo, Nathascja Katia
    Di Leo, Giovanni
    Papini, Giacomo Davide Edoardo
    Ulivieri, Fabio Massimo
    Sardanelli, Francesco
    EUROPEAN RADIOLOGY, 2015, 25 (05) : 1504 - 1511
  • [48] Evaluation of femoral head bone quality by Hounsfield units: a comparison with dual-energy X-ray absorptiometry
    Kilinc, Rabia Mihriban
    Acan, Ahmet Emrah
    Turk, Gamze
    Kilinc, Cem Yalin
    Yeniceri, Ibrahim Onder
    ACTA RADIOLOGICA, 2022, 63 (07) : 933 - 941
  • [49] BatchBMD as an Efficient and Accurate Dual-Energy X-ray Absorptiometry Report Generator
    Chan, Chun-Hsiang
    Huang, Wen-Chi
    Lu, Yi-Chien
    Hsiao, Hsing-Fen
    Chan, Wing P.
    DIAGNOSTICS, 2021, 11 (12)
  • [50] Dual-Energy X-ray Absorptiometry Scan Autoanalysis vs Manual Analysis
    Baniak, Nicholas
    Grzybowski, Stephanie
    Olszynski, Wojciech P.
    JOURNAL OF CLINICAL DENSITOMETRY, 2014, 17 (01) : 97 - 103