A critical appraisal of the quality of adult dual-energy X-ray absorptiometry guidelines in osteoporosis using the AGREE II tool: An EuroAIM initiative

被引:24
|
作者
Messina, Carmelo [1 ]
Bignotti, Bianca [2 ]
Bazzocchi, Alberto [3 ]
Phan, Catherine M. [4 ]
Tagliafico, Alberto [5 ,6 ]
Guglielmi, Giuseppe [7 ]
Sardanelli, Francesco [8 ,9 ]
Sconfienza, Luca Maria [9 ,10 ]
机构
[1] Univ Milan, Scuola Specializzaz Radiodiagnost, Via Festa Perdono 7, I-20122 Milan, Italy
[2] Univ Genoa, Dept Hlth Sci, Genoa, Italy
[3] Rizzoli Orthopaed Inst, Diagnost & Intervent Radiol, Via GC Pupilli 1, I-40136 Bologna, Italy
[4] St Antoine Hosp, Dept Radiol, Paris, France
[5] Univ Genoa, Genoa, Italy
[6] AOU IRCCS San Martino IST, Genoa, Italy
[7] Univ Foggia, Dept Radiol, Foggia, Italy
[8] IRCCS Policlin San Donato, Serv Radiol, Piazza Malan 1, I-20097 San Donato Milanese, Italy
[9] Univ Milan, Dipartimento Sci Biomed Salute, Via Pascal 36, I-20133 Milan, Italy
[10] IRCCS Ist Ortoped Galeazzi, Unita Operat Radiol Diagnost & Interventist, Via Riccardo Galeazzi 4, I-20161 Milan, Italy
来源
INSIGHTS INTO IMAGING | 2017年 / 8卷 / 03期
关键词
Dual-energyX-ray absorptiometry; DXA; Guidelines; Agree; Evidence based medicine; CLINICAL-PRACTICE GUIDELINES; RECOMMENDATIONS; PREVALENCE; CANADA;
D O I
10.1007/s13244-017-0553-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Dual energy X-ray absorptiometry (DXA) is the most widely used technique to measure bone mineral density (BMD). Appropriate and accurate use of DXA is of great importance, and several guidelines have been developed in the last years. Our aim was to evaluate the quality of published guidelines on DXA for adults. Methods Between June and July 2016 we conducted an online search for DXA guidelines, which were evaluated by four independent readers blinded to each other using the AGREE II instrument. A fifth independent reviewer calculated scores per each domain and agreement between reviewers' scores. Results Four out of 59 guidelines met inclusion criteria and were included. They were published between 2005 and 2014. Three out of four guidelines reached a high level of quality, having at least five domain scores higher than 60%. Domain 1 (Scope and Purpose) achieved the highest result (total score = 86.8 +/- 3.7%). Domain 6 (Editorial Independence) had the lowest score (total score = 54.7 +/- 12.5%). Interobserver agreement ranged from fair (0.230) to good (0.702). Conclusions Overall, the quality of DXA guidelines is satisfactory when evaluated using the AGREE II instrument. The Editorial Independence domain was the most critical, thus deserving more attention when developing future guidelines. Main messages Three of four guidelines on DXA had a high quality level (> 60%). Scope/purpose had the highest score (86.8 +/- 3.7%). Editorial Independence had the lowest score (54.7 +/- 12.5%). Interobserver agreement ranged from fair (0.230) to good (0.702).
引用
收藏
页码:311 / 317
页数:7
相关论文
共 50 条
  • [31] Dual-energy X-ray absorptiometry bone densitometry and pitfalls in the assessment of osteoporosis: a primer for the practicing clinician
    Chen Pong Wong
    Linsey Utami Gani
    Le Roy Chong
    Archives of Osteoporosis, 2020, 15
  • [32] Assessing osteopenia and osteoporosis with dual-energy x-ray absorptiometry studies in Fabry disease
    Alyaa Shmara
    Grace Lee
    Mania Mgdsyan
    Kathy Hall
    Nadia Sadri
    Angela Martin-Rios
    Kelsey Valentine
    Tatiana Kain
    Madeleine Pahl
    Lynda E. Polgreen
    Virginia Kimonis
    Orphanet Journal of Rare Diseases, 20 (1)
  • [33] Dual-energy X-ray absorptiometry bone densitometry and pitfalls in the assessment of osteoporosis: a primer for the practicing clinician
    Wong, Chen Pong
    Gani, Linsey Utami
    Chong, Le Roy
    ARCHIVES OF OSTEOPOROSIS, 2020, 15 (01)
  • [34] Dual-energy X-Ray Absorptiometry: Interpreting Reports and Serial Measurements
    Bonnick, Sydney L.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2013, 56 (04) : 677 - 685
  • [35] Body composition analysis of pigs by dual-energy x-ray absorptiometry
    Mitchell, AD
    Conway, JM
    Potts, WJE
    JOURNAL OF ANIMAL SCIENCE, 1996, 74 (11) : 2663 - 2671
  • [36] Effect of the lumbar scoliosis on the results of dual-energy X-ray absorptiometry
    Kirilov, Nikola
    Kirilova, Elena
    Todorov, Svilen
    Nikolov, Nikolay
    ORTHOPEDIC REVIEWS, 2020, 12 (01) : 37 - 40
  • [37] Adult Dual-Energy X-ray Absorptiometry in Clinical Practice: How I Report it
    Messina, Carmelo
    Sconfienza, Luca Maria
    Bandirali, Michele
    Guglielmi, Giuseppe
    Ulivieri, Fabio Massimo
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2016, 20 (03) : 246 - 253
  • [38] CZT detector for dual-energy x-ray absorptiometry (DEXA)
    Wear, J
    Buchholz, M
    Payne, R
    Gorsuch, D
    Bisek, J
    Ergun, D
    Grosholz, J
    Falk, R
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 175 - 188
  • [39] Classifying Dual-Energy X-ray Absorptiometry Images Using Machine Learning
    Kirilov, Nikola K.
    Kirilova, Elena K.
    2021 56TH INTERNATIONAL SCIENTIFIC CONFERENCE ON INFORMATION, COMMUNICATION AND ENERGY SYSTEMS AND TECHNOLOGIES (ICEST), 2021, : 53 - 54
  • [40] Hip axis length measurement using dual-energy X-ray absorptiometry
    Roux, C
    Kolta, S
    Fechtenbaum, J
    Dougados, M
    REVUE DU RHUMATISME, 1997, 64 (04): : 243 - 248