Measurement of formaldehyde in a single puff of cigarette smoke using tunable diode laser infrared spectroscopy

被引:40
作者
Parrish, ME [1 ]
Harward, CN [1 ]
机构
[1] Philip Morris USA, RD&E, Richmond, VA 23261 USA
关键词
TDL infrared spectroscopy; formaldehyde; cigarette smoke; tobacco smoke;
D O I
10.1366/0003702001948709
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A mettled has been developed for measuring formaldehyde in single puffs of mainstream (MS) and per cigarette in sidestream (SS) smoke with the use of tunable diode laser (TDL) infrared spectroscopy, Thirty to fifty percent of the total MS formaldehyde delivery per cigarette is generated in the lighting puff. This phenomenon is unique to formaldehyde compared to most other gaseous smoke components. The effect of the lighting technique, parking density of the tobacco in the cigarette rod, flow rate of air (heating rate) through the cigarette coal (burning zone), and tobacco type on the formaldehyde levels were studied. Calibration was based on measuring the second-derivative spectral response of formaldehyde generated from certified paraformaldehyde permeation tubes. The accuracy of the measured value of this standard was determined to be within +/-0.7% of the certified formaldehyde delivery by performing periodic gravimetric measurements. In addition, the formaldehyde standard was collected in a water trap and analyzed by using a colorimetric analytical technique, providing an agreement of +/-2% with the TDL measurement, The TDL method precision was less than or equal to1% with the use of the permeation standard. The MS formaldehyde deliveries for a Philip Morris monitor and Kentucky Reference 1R4F cigarette were 37 +/- 5 and 27 +/- 5 mug/cigt., respectively. The 1R4F value was in close agreement with results found by using an HPLC method reported in the literature. The MS sampling system can be quickly modified to determine formaldehyde levels in sidestream smoke. The SS formaldehyde delivery for the Philip Morris monitor cigarette was 2.1 +/- 0.1 mg/cigt. (i.e., 0.27 +/- 0.01 mg/min). The range of SS deliveries for reference, experimental, and commercial brands was much less than that observed for the MS smoke deliveries of similar cigarettes.
引用
收藏
页码:1665 / 1677
页数:13
相关论文
共 40 条
  • [31] Real-time monitoring of polycyclic aromatic hydrocarbons in cigarette smoke using time-resolved laser-induced fluorescence
    Song, JM
    Jagannathan, R
    Stokes, DL
    Vo-Dinh, T
    Hajaligol, MR
    POLYCYCLIC AROMATIC COMPOUNDS, 2003, 23 (04) : 429 - 439
  • [32] Strategies for formaldehyde engines using a single-mode detection in flames and Nd:YAG/OPO laser system
    Brackmann, C
    Li, ZS
    Rupinski, M
    Docquier, N
    Pengloan, G
    Aldén, M
    APPLIED SPECTROSCOPY, 2005, 59 (06) : 763 - 768
  • [33] Simultaneous determination of nicotine and 3-vinylpyridine in single cigarette tobacco smoke and in indoor air using direct extraction to solid phase
    Koszowski, Bartosz
    Goniewicz, Maciej Lukasz
    Czogala, Jan
    Zymelka, Anna
    Sobczak, Andrzej
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (02) : 105 - 117
  • [34] Sensitivity-Enhanced Fourier Transform Mid-Infrared Spectroscopy Using a Supercontinuum Laser Source
    Zorin, Ivan
    Kilgus, Jakob
    Duswald, Kristina
    Lendl, Bernhard
    Heise, Bettina
    Brandstetter, Markus
    APPLIED SPECTROSCOPY, 2020, 74 (04) : 485 - 493
  • [35] Highly sensitive portable laser absorption spectroscopy formaldehyde sensor using compact spherical mirror multi-pass cell
    Fang, Bo
    Yang, Nana
    Wang, Chunhui
    Zhao, Weixiong
    Zhou, Hao
    Zhang, Weijun
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 394
  • [36] A rapid and selective method for simultaneous determination of six toxic phenolic compounds in mainstream cigarette smoke using single-drop microextraction followed by liquid chromatography-tandem mass spectrometry
    Saha, Subhrakanti
    Mistri, Rajib
    Ray, Bidhan Chandra
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (28) : 9265 - 9272
  • [37] Measurement of atmospheric formaldehyde and monoaromatic hydrocarbons using differential optical absorption spectroscopy during winter and summer intensive periods in Seoul, Korea
    Lee, CY
    Kim, YJ
    Hong, SB
    Lee, H
    Jung, JS
    Choi, YJ
    Park, J
    Kim, KH
    Lee, JH
    Chun, KJ
    Kim, HH
    WATER AIR AND SOIL POLLUTION, 2005, 166 (1-4) : 181 - 195
  • [38] Measurement of Atmospheric Formaldehyde and Monoaromatic Hydrocarbons using Differential Optical Absorption Spectroscopy during Winter and Summer Intensive Periods in Seoul, Korea
    Chulkyu Lee
    Young Joon Kim
    Sang-Bum Hong
    Hanlim Lee
    Jinsang Jung
    Yeo-Jin Choi
    Jungeun Park
    Ki-Hyun Kim
    Jai-Hoon Lee
    Ki-Joon Chun
    Hyun-Ho Kim
    Water, Air, and Soil Pollution, 2005, 166 : 181 - 195
  • [39] A rapid and selective method for simultaneous determination of six toxic phenolic compounds in mainstream cigarette smoke using single-drop microextraction followed by liquid chromatography–tandem mass spectrometry
    Subhrakanti Saha
    Rajib Mistri
    Bidhan Chandra Ray
    Analytical and Bioanalytical Chemistry, 2013, 405 : 9265 - 9272
  • [40] Ppb-level mid-infrared ethane detection based on three measurement schemes using a 3.34-μm continuous-wave interband cascade laser
    Li, Chunguang
    Zheng, Chuantao
    Dong, Lei
    Ye, Weilin
    Tittel, Frank K.
    Wang, Yiding
    APPLIED PHYSICS B-LASERS AND OPTICS, 2016, 122 (07):