Concept of left atrial pressure estimation using its pulsatile amplitude in the helical flow total artificial heart

被引:2
作者
Wu, Sheng-Yuan [1 ]
Saito, Itsuro [1 ]
Isoyama, Takashi [1 ]
Inoue, Yusuke [2 ]
Sato, Masami [1 ]
Hara, Shintaro [1 ]
Li, Xin-Yang [1 ]
Yurimoto, Terumi [1 ]
Murakami, Haruka [1 ]
Kawase, Yukino [3 ]
Ono, Toshiya [1 ]
Abe, Yusuke [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Biomed Engn, Bunkyo Ku, Tokyo 1130033, Japan
[2] Univ Tokyo, Grad Sch Engn, Dept Elect Engn & Informat Syst, Tokyo 1130033, Japan
[3] Kitasato Univ, Grad Sch Med Sci, Sagamihara, Kanagawa 228, Japan
关键词
Total artificial heart; Atrial pressure; Estimation; Compliance; Sensor; PUMP;
D O I
10.1007/s10047-014-0788-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The total artificial heart (TAH) requires physiological control to respond to the metabolic demand of the body. To date, 1/R control is a single physiological control method that can control venous pressure. To realize an implantable 1/R control system, we are developing a new pressure measuring method using absolute pressure sensor. To find a method for absolute pressure sensor, which went well without calibration, concept of left atrial pressure (LAP) estimation using its pulsatile amplitude was proposed. Its possibility was investigated with two long-term survived goats whose hearts were replaced with the helical flow TAHs. In manual control condition, there existed a positive relation between mean LAP (mLAP) and normalized pulsatile amplitude (NPA). Percent systole revealed not to affect the relationship between mLAP and NPA. Dispersion was observed between different pulse rates. As for cardiac output difference (QLD) that is the difference of flow rate between systolic and diastolic phases, similar results were obtained except in low QLDs. In the 1/R control condition, relatively high correlation between mLAP and NPA could be obtained. In estimation of mLAP using the correlating function of individual goat, fairly good correlation was obtained between measured mLAP and estimated mLAP. Despite that further studies are necessary, it was demonstrated that the concept of the LAP estimation could be possible.
引用
收藏
页码:301 / 307
页数:7
相关论文
共 14 条
  • [1] Physiological control of a total artificial heart: conductance- and arterial pressure-based control
    Abe, Y
    Chinzei, T
    Mabuchi, K
    Snyder, AJ
    Isoyama, T
    Imanishi, K
    Yonezawa, T
    Matsuura, H
    Kouno, A
    Ono, T
    Atsumi, K
    Fujimasa, I
    Imachi, K
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (03) : 868 - 876
  • [2] Abe Y, 1998, HEART REPLACEMENT AR, V4, P34
  • [3] Abe Y, 2013, IEEE ENG MED BIO, P2720, DOI 10.1109/EMBC.2013.6610102
  • [4] The helical flow pump with a hydrodynamic levitation impeller
    Abe, Yusuke
    Ishii, Kohei
    Isoyama, Takashi
    Saito, Itsuro
    Inoue, Yusuke
    Ono, Toshiya
    Nakagawa, Hidemoto
    Nakano, Emiko
    Fukazawa, Kyoko
    Ishihara, Kazuhiko
    Fukunaga, Kazuyoshi
    Ono, Minoru
    Imachi, Kou
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2012, 15 (04) : 331 - 340
  • [5] Aufiero T X, 1987, ASAIO Trans, V33, P157
  • [6] HENNIG E, 1978, T AM SOC ART INT ORG, V24, P616
  • [7] HILLER KW, 1962, T AM SOC ART INT ORG, V8, P125
  • [8] PIERCE WS, 1976, T AM SOC ART INT ORG, V22, P347
  • [9] Saito I, 2008, IFMBE PROC, V19, P62, DOI 10.1007/978-3-540-79039-6_17
  • [10] Automatic calibration of the inlet pressure sensor for the implantable continuous-flow ventricular assist device
    Shi, Wei
    Saito, Itsuro
    Isoyama, Takashi
    Nakagawa, Hidemoto
    Inoue, Yusuke
    Ono, Toshiya
    Kouno, Akimasa
    Imachi, Kou
    Abe, Yusuke
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2011, 14 (02) : 81 - 88