Ganoderma species discrimination by dual-mode chromatographic fingerprinting: A study on stationary phase effects in hydrophilic interaction chromatography and reduction of sample misclassification rate by additional use of reversed-phase chromatography

被引:34
作者
Chen, Yi [1 ,2 ]
Bicker, Wolfgang [1 ]
Wu, JunYan [1 ]
Xie, Ming Yong [2 ]
Lindner, Wolfgang [1 ]
机构
[1] Univ Vienna, Dept Analyt Chem & Food Chem, Christian Doppler Lab Mol Recognit Mat, A-1090 Vienna, Austria
[2] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Peoples R China
关键词
Hydrophilic interaction chromatography; Reversed-phase chromatography; Column classification; Chromatographic fingerprint; Chemometrics; Natural product analysis; CHINESE HERBAL MEDICINES; LIQUID-CHROMATOGRAPHY; QUALITY-CONTROL; SEPARATION; RETENTION; LUCIDUM; LINGZHI; SYSTEM; HPLC;
D O I
10.1016/j.chroma.2009.12.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Acetonitrile-water extracts of several Ganoderma species - a mushroom being used in Traditional Chinese Medicine-were analysed by liquid chromatography-UV detection in hydrophilic interaction chromatography (HILIC) and reversed-phase (RP) elution modes A set of six polar stationary phases was used for HILIC runs These columns had remarkably different separation properties under binary gradient conditions as evinced by hierarchical cluster analysis on retention patterns of seven test Compounds Complementary measurements of RP chromatograms were carried out on a C-18 packing Injection precision (it = 5) and intra-clay precision (it = 5) were each <2 0% RSD (HILIC) and <0 7% RSD (RP) for relative retention times of main characteristic peaks of a sample exit act while for relative peak areas RSD values were max. 6.8%. Repetitive analysis (it = 7) of a processed sample stored in the autosampler tray for 48 h was used to confirm within-sequence sample stability Eleven Ganoderma luctdum samples served as it training set for the construction of column-specific simulated mean chromatograms Validation with twelve samples comprising G. lucidum. Ganoderma sinense. Ganoderma atrum, and Ganoderma tsugac by cot relation coefficient based similarity evaluation of peak patterns showed that a discrimination of G. lucidum from other Ganoderma species by means of chromatographic fingerprints is conceptually possible on all columns. except of a bare silica packing The importance of the combined use of RP and HILIC fingerprints to Improve the rate of correct sample classification was demonstrated by the fact that each one G sinense specimen was wrongly assigned being G lucidum by all HILIC fingerprints but not the RP fingerprint and vice versa The present data revealed that (I) the analysis of complex biological materials by quasi orthogonal chromatographic modes such as HILIC and RP may deliver more discriminative information than single-mode approaches which strengthens the reliability of fingerprint-based sample classification and (it) different retention and selectivity characteristics of polar bonded silica packings in the HILIC elution mode m ay only have a minor impact on chemometric sample discrimination capabilities In such kind of pattern-oriented metabolomics separation problems (C) 2009 Elsevter B V All I fights reserved
引用
收藏
页码:1255 / 1265
页数:11
相关论文
共 16 条
  • [1] Preparation of a monolithic column with a mixed-mode stationary phase of reversed-phase/hydrophilic interaction for capillary liquid chromatography
    Zhang, Meng
    Gong, Li
    Liu, Guizhen
    Kang, Jingwu
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (03) : 662 - 669
  • [2] Separation properties of novel and commercial polar stationary phases in hydrophilic interaction and reversed-phase liquid chromatography mode
    Wu, JunYan
    Bicker, Wolfgang
    Lindner, Wolfgang
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (09) : 1492 - 1503
  • [3] Preparation and Evaluation of Poly-L-Lysine Stationary Phase for Hydrophilic Interaction/Reversed-Phase Mixed-Mode Chromatography
    Li, Yuanyuan
    Xu, Zhigang
    Feng, Yaoyao
    Liu, Xiaoyan
    Chen, Tong
    Zhang, Haixia
    CHROMATOGRAPHIA, 2011, 74 (7-8) : 523 - 530
  • [4] New poly(ionic liquid)-grafted silica multi-mode stationary phase for anion-exchange/reversed-phase/hydrophilic interaction liquid chromatography
    Qiu, Hongdeng
    Mallik, Abul K.
    Takafuji, Makoto
    Jiang, Shengxiang
    Ihara, Hirotaka
    ANALYST, 2012, 137 (11) : 2553 - 2555
  • [5] Core-Shell Metal-Organic Frameworks as the Mixed-Mode Stationary Phase for Hydrophilic Interaction/Reversed-Phase Chromatography
    Li, Xueyun
    Li, Bo
    Liu, Mingchen
    Zhou, Yufeng
    Zhang, Liyuan
    Qiao, Xiaoqiang
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (10) : 10320 - 10327
  • [6] Imidazolium embedded C8 based stationary phase for simultaneous reversed-phase/hydrophilic interaction mixed-mode chromatography
    Qiao, Xiaoqiang
    Zhang, Lu
    Zhang, Niu
    Wang, Xin
    Qin, Xinying
    Yan, Hongyuan
    Liu, Haiyan
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1400 : 107 - 116
  • [7] Imidazolium-embedded iodoacetamide-functionalized silica-based stationary phase for hydrophilic interaction/reversed-phase mixed-mode chromatography
    Wang, Huizhen
    Zhang, Lu
    Ma, Teng
    Zhang, Liyuan
    Qiao, Xiaoqiang
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (18) : 3498 - 3504
  • [8] Tetra-proline-modified calix[4]arene-bonded silica stationary phase for simultaneous reversed-phase/hydrophilic interaction mixed-mode chromatography
    Zhang, Wenfen
    Zhang, Yongming
    Zhang, Guangrui
    Ba, Xin
    Xia, Shaige
    Zhao, Wuduo
    Yin, Dan
    Zhang, Shusheng
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (07) : 1374 - 1383
  • [9] Novel imidazolium-embedded N,N-dimethylaminopropyl-functionalized silica-based stationary phase for hydrophilic interaction/reversed-phase mixed-mode chromatography
    Liu, Shijia
    Xu, Hongxin
    Yu, Jiaojiao
    Li, Danyang
    Li, Mingyan
    Qiao, Xiaoqiang
    Qin, Xinying
    Yan, Hongyuan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (30) : 8989 - 8997
  • [10] A new strategy for the preparation of core-shell MOF/Polymer composite material as the mixed-mode stationary phase for hydrophilic interaction/ reversed-phase chromatography
    Si, Tiantian
    Lu, Xiaofeng
    Zhang, Haixia
    Liang, Xiaojing
    Wang, Shuai
    Guo, Yong
    ANALYTICA CHIMICA ACTA, 2021, 1143 : 181 - 188