Validity and reliability of the GYKO inertial sensor system for the assessment of the elbow range of motion

被引:12
|
作者
Santospagnuolo, Adriano [1 ]
Bruno, Andrea A. [1 ]
Pagnoni, Andrea [1 ]
Martello, Federico [1 ]
Santoboni, Flavia [1 ,2 ]
Perroni, Fabrizio [3 ]
Vulpiani, Maria Chiara [1 ,2 ]
Vetrano, Mario [1 ]
机构
[1] Sapienza Univ, St Andrea Hosp, Unit Phys Med & Rehabil, I-00189 Rome, Italy
[2] Italian Natl Olymp Comm CONI, Sports Med Inst, Rome, Italy
[3] eCampus Univ, Sch Sport & Exercise Sci, Novedrate, Como, Italy
来源
JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS | 2019年 / 59卷 / 09期
关键词
Elbow; Articular range of motion; Evaluation studies; Diagnostic equipment; CONCURRENT VALIDITY; GONIOMETRIC RELIABILITY; JOINTS;
D O I
10.23736/S0022-4707.19.09331-9
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
BACKGROUND: The evaluation of joints range of motion (ROM) represents a fundamental step in the diagnosis of joint disorders. Assessors usually measure the ROM angle through a universal goniometer (UG). GYKO inertial system (Microgate, Bolzano, Italy) represent a noninvasive, easy-to-use. Inertial Measurement Unit (IMU) method for the measurement of the elbow ROM. The aim of this study was to validate the GYKO digital device comparing it with the gold standard UG in the measurement of elbow flexion-extension ROM in healthy subjects. METHODS: Thirty healthy subjects (15 females, 15 males; mean age: 34 years, range 25-58 years) were enrolled. The elbow ROM of the dominant ann was measured with two methods, UG and GYKO. Active flexion-extension movement of the elbow was measured by two operators with UG (A1_UG; A2 UG) and with GYKO (A1_GYKO; A2_GYKO; B_GYKO). Intra-rater reliability, inter-rater reliability, and concurrent validity were analyzed by intraclass correlation coefficient (ICC) values. Bland-Altman plot was used to compare UG and GYKO. RESULTS: Both methods were very reliable (P<0.001). Intra-rater reliability showed strong correlation respectively for the UG (ICC-0.798) and for GYKO (ICC-0.859) while inter-rater reliability showed moderate correlation with UG (ICC-0.726) and strong correlation with GYKO (ICC=0.942). The concurrent validity, obtained by three comparisons (A1, A2 and B) showed moderate correlation (ICC: 0.576-0.776). CONCLUSIONS: The results of this study support the use of GYKO as useful as the UG for the assessment of the active flexion-extension ROM of the elbow.
引用
收藏
页码:1466 / 1471
页数:6
相关论文
共 50 条
  • [1] Validity and reliability of inertial sensors for elbow and wrist range of motion assessment
    Costa, Vanina
    Ramirez, Oscar
    Otero, Abraham
    Munoz-Garcia, Daniel
    Uribarri, Sandra
    Raya, Rafael
    PEERJ, 2020, 8
  • [2] Reliability and validity of the Microgate Gyko for measuring range of motion of the low back
    Hamersma, Dave T.
    Hofste, Anke
    Rijken, Noortje H. M.
    Rohe, Moniek Roe of
    Oosterveld, Frits G. J.
    Soer, Remko
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2020, 45
  • [3] Cervical Range of Motion Assessment through Inertial Technology: A Validity and Reliability Study
    Palmieri, Martina
    Donno, Lucia
    Cimolin, Veronica
    Galli, Manuela
    SENSORS, 2023, 23 (13)
  • [4] Validity and Reliability of Inertial Measurement Units in Active Range of Motion Assessment in the Hip Joint
    Stolowski, Lukasz
    Niedziela, Maciej
    Lubiatowski, Bartlomiej
    Lubiatowski, Przemyslaw
    Piontek, Tomasz
    SENSORS, 2023, 23 (21)
  • [5] Concurrent validity of the Gyko inertial sensor system for the assessment of vertical jump height in female sub-elite youth soccer players
    Lesinski M.
    Muehlbauer T.
    Granacher U.
    BMC Sports Science, Medicine and Rehabilitation, 8 (1)
  • [6] Reliability and validity of the Microgate Gyko for measuring range of motion o the low back [vol 45, 102091, 2020]
    Hamersma, Dave T.
    Hofste, Anke
    Rijken, Noortje H. M.
    Roe Of Rohe, Moniek
    Oosterveld, Frits G. J.
    Soer, Remko
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2023, 63
  • [7] Reliability and Validity of a Wearable Inertial Sensor System for Gait Assessment in Healthy Young Adults
    Hou, Ying
    Wang, Shujia
    Li, Jinping
    Komal, Sana
    Li, Ke
    2021 14TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2021), 2021,
  • [8] Concurrent Validity and Reliability of an Inertial Measurement Unit for the Assessment of Craniocervical Range of Motion in Subjects with Cerebral Palsy
    Carmona-Perez, Cristina
    Luis Garrido-Castro, Juan
    Torres Vidal, Francisco
    Alcaraz-Clariana, Sandra
    Garcia-Luque, Lourdes
    Alburquerque-Sendin, Francisco
    Priscila Rodrigues-de-Souza, Daiana
    DIAGNOSTICS, 2020, 10 (02)
  • [9] The validity of a single inertial sensor to assess cervical active range of motion
    English, Daniel J.
    Weerakkody, Nivan
    Zacharias, Anita
    Green, Rodney A.
    Hocking, Cassandra
    Bini, Rodrigo Rico
    JOURNAL OF BIOMECHANICS, 2023, 159
  • [10] Evaluation of measurement reliability for selected indices of postural stability based on data from the GYKO Inertial Sensor System
    Jaworski, Janusz
    Lech, Grzegorz
    Witkowski, Kazimierz
    Kubacki, Rafal
    Piepiora, Pawel
    BIOLOGY OF SPORT, 2024, 41 (02) : 155 - 161