Lead(II)-Induced Allosteric G-Quadruplex DNAzyme as a Colorimetric and Chemiluminescence Sensor for Highly Sensitive and Selective Pb2+ Detection

被引:336
作者
Li, Tao
Wang, Erkang [1 ]
Dong, Shaojun
机构
[1] Chinese Acad Sci, State Key Lab Electroanalyt Chem, Changchun Inst Appl Chem, Changchun 130022, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
PEROXIDASE-ACTIVITY; GOLD NANOPARTICLES; AMPLIFIED DETECTION; TELOMERASE ACTIVITY; CATALYTIC DNA; LEAD IONS; LABEL; CHEMOSENSORS; BIOSENSOR; APTAMER;
D O I
10.1021/ac902638v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The lead ion (Pb2+) has been proven to induce a conformational change of K-stabilized G-quadruplex DNAzyme and inhibit the peroxidase-like activity [Li, T.; Wang, E.; Dong, S. J. Am. Chem. Soc. 2009, 131, 15082-15083]. Ibis provides a rationale for utilizing Pb2+-induced allosteric G-quadruplex DNAzyme to probe aqueous Pb2+. Here, we choose a common G-quadruplex DNAzyme named PS2.M to develop a novel Pb2+ sensor with two detection means: colorimetry and chemiluminescence (CL). In the presence of K+, PS2.M (with hemin as a cofactor) exhibits a superior DNAzyme activity and effectively catalyzes the H2O2-mediated oxidation of 2,2'-azino-bis(3-ethylben-zothiazoline-6-sulfonic acid) diammonium salt (ABTS) or luminol, which results in a color change or generates CL emission. Upon the addition of Pbl(2+), K-stabilized PS2.M is induced to convert to the Pb2+-stabilized structure with higher stability but lower DNAzyme activity, which is reflected by an obvious increase in DNA melting temperature but a sharp decrease in readout signal. This allows us to utilize PS2.M for quantitative analysis of aqueous Pb2+ using the ABTS-H2O2 colorimetric system and luminol-H2O2 CL system. In each case, the readout signal is linearly dependent on the logarithm of Pb2+ concentration within a certain range. Nevertheless, two sensing systems provide different sensitivity for Ph2+ analysis. With colorimetry, Pb2+ can be detected at a level of 32 nM (similar to 7 ppb), whereas the detection limit of Pb2+ is 1 nM (0.2 ppb) when utilizing the CL method. In addition to high sensitivity, the above sensing systems exhibit good selectivity for Pb2+ over other metal ions. These results demonstrate the facility and effectivity of our introduced DNAzyme-based sensor for quantitative Pb2+ analysis.
引用
收藏
页码:1515 / 1520
页数:6
相关论文
共 39 条
  • [1] CHEMICAL COMMUNICATION IN WATER USING FLUORESCENT CHEMOSENSORS
    CZARNIK, AW
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 1994, 27 (10) : 302 - 308
  • [2] Immobilization of DNAzyme catalytic beacons on PMMA for Pb2+ detection
    Dalavoy, Tulika S.
    Wernette, Daryl P.
    Gong, Maojun
    Sweedler, Jonathan V.
    Lu, Yi
    Flachsbart, Bruce R.
    Shannon, Mark A.
    Bohn, Paul W.
    Cropek, Donald M.
    [J]. LAB ON A CHIP, 2008, 8 (05) : 786 - 793
  • [3] A DNAzyme cascade for the amplified detection of Pb2+ ions or L-histidine
    Elbaz, Johann
    Shlyahovsky, Bella
    Willner, Itamar
    [J]. CHEMICAL COMMUNICATIONS, 2008, (13) : 1569 - 1571
  • [4] Folding of the thrombin aptamer into a G-quadruplex with Sr2+:: Stability, heat, and hydration
    Kankia, BI
    Marky, LA
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (44) : 10799 - 10804
  • [5] A lead-filled G-quadruplex:: Insight into the G-quartet's selectivity for Pb2+ over K+
    Kotch, FW
    Fettinger, JC
    Davis, JT
    [J]. ORGANIC LETTERS, 2000, 2 (21) : 3277 - 3280
  • [6] Structure-function investigation of a deoxyribozyme with dual chelatase and peroxidase activities
    Lee, HW
    Chinnapen, DJF
    Sen, D
    [J]. PURE AND APPLIED CHEMISTRY, 2004, 76 (7-8) : 1537 - 1545
  • [7] Optical analysis of Hg2+ ions by oligonucleotide-gold-nanoparticle hybrids and DNA-based machines
    Li, Di
    Wieckowska, Agnieszka
    Willner, Itamar
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (21) : 3927 - 3931
  • [8] A highly sensitive and selective catalytic DNA biosensor for lead ions
    Li, J
    Lu, Y
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (42) : 10466 - 10467
  • [9] Comparison of Cyanide and Carbon Monoxide as Ligands in Iron(II) Porphyrinates
    Li, Jianfeng
    Noll, Bruce C.
    Schulz, Charles E.
    Scheidt, W. Robert
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (27) : 5010 - 5013
  • [10] Cyanide: A Strong-Field Ligand for Ferrohemes and Hemoproteins?
    Li, Jianfeng
    Lord, Richard L.
    Noll, Bruce C.
    Baik, Mu-Hyun
    Schulz, Charles E.
    Scheidt, W. Robert
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (52) : 10144 - 10146