Evaluation and comparison of the kinetic performance of ultra-high performance liquid chromatography and high-performance liquid chromatography columns in hydrophilic interaction and reversed-phase liquid chromatography conditions

被引:32
|
作者
Song, Huiying [1 ]
Adams, Erwin [1 ]
Desmet, Gert [2 ]
Cabooter, Deirdre [1 ]
机构
[1] Katholieke Univ Leuven, Dept Pharmaceut & Pharmacol Sci, Leuven, Belgium
[2] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
关键词
HILIC; RPLC; Kinetic plot; Porosity; Flow resistance; PARTICLE-SIZE DISTRIBUTION; SUB-2; MU-M; MASS-SPECTROMETRY; DEAD-VOLUME; SEPARATION; RETENTION; QUANTIFICATION; ADSORPTION; EPHEDRINES; MECHANISM;
D O I
10.1016/j.chroma.2014.10.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An intrinsic performance comparison is made of the reduction in analysis time that can be obtained when switching from HPLC to UHPLC column formats in HILIC and reversed-phase conditions. A detailed overview of the packing characteristics of both stationary phase types is given first. It is demonstrated that HILIC columns demonstrate higher external porosity values than their reversed-phase counterparts resulting in lower flow resistance values. Column total porosity values determined from the elution time of a small marker molecule are shown to depend strongly on the composition of the mobile phase. To omit errors that might arise from an over- or underestimation of the column void time, all plate height and kinetic plot data are therefore expressed as a function of the interstitial velocity. Although only a limited number of columns are evaluated in this study, it is shown that the column efficiency of the HILIC columns is lower than that of their reversed-phase counterparts, at least for the compounds evaluated here. Despite this lower efficiency, the kinetic performance of both stationary phase types is similar, due to the much lower viscosity of the mobile phases typically used in HILIC conditions. Finally, it is demonstrated that a similar, yet slightly larger reduction in analysis time can be obtained when switching from HPLC column formats to UHPLC formats in HILIC compared to reversed-phase conditions. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:83 / 91
页数:9
相关论文
共 50 条
  • [41] Fast and simultaneous analysis of biothiols by high-performance liquid chromatography with fluorescence detection under hydrophilic interaction chromatography conditions
    Isokawa, Muneki
    Funatsu, Takashi
    Tsunoda, Makoto
    ANALYST, 2013, 138 (13) : 3802 - 3808
  • [42] EVALUATION OF THE QUALITY OF ANGELICA SINENSIS BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Wang, Zhenzhong
    Shao, Shijun
    ANALYTICAL LETTERS, 2014, 47 (18) : 2857 - 2870
  • [43] Optimizing selectivity during reversed-phase high performance liquid chromatography method development: Prioritizing experimental conditions
    Snyder, Lloyd R.
    Dolan, John W.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1302 : 45 - 54
  • [44] Fingerprint analysis of Ligusticum chuanxiong using hydrophilic interaction chromatography and reversed-phase liquid chromatography
    Jin, Yu
    Liang, Tu
    Fu, Qing
    Xiao, Yuan-Sheng
    Feng, Jia-Tao
    Ke, Yan-Xiong
    Liang, Xin-Miao
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (11) : 2136 - 2141
  • [45] Mobile Phase Effects in Reversed-Phase and Hydrophilic Interaction Liquid Chromatography
    Jandera, Pavel
    Hajek, Tarns
    ADVANCES IN CHROMATOGRAPHY, VOL 57, 2021, 57 : 1 - 58
  • [46] Destructive stationary phase gradients for reversed-phase/hydrophilic interaction liquid chromatography
    Cain, Caitlin N.
    Forzano, Anna, V
    Rutan, Sarah C.
    Collinson, Maryanne M.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1570 : 82 - 90
  • [47] Mobile phase effects in reversed-phase and hydrophilic interaction liquid chromatography revisited
    Jandera, Pavel
    Hajek, Tomas
    Sromova, Zuzana
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1543 : 48 - 57
  • [48] Cholesterol capillary monolithic columns for reversed-phase liquid chromatography
    Grzywinski, Damian
    Szumski, Michal
    Buszewski, Boguslaw
    PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY", 2015, : 12 - 18
  • [49] Is hydrophilic interaction chromatography with silica columns a viable alternative to reversed-phase liquid chromatography for the analysis of ionisable compounds?
    McCalley, David V.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1171 (1-2) : 46 - 55
  • [50] Comparison of the Fitting Performance of Retention Models and Elution Strength Behaviour in Hydrophilic-Interaction and Reversed-Phase Liquid Chromatography
    Peris-Garcia, Ester
    Jose Ruiz-Angel, Maria
    Jose Baeza-Baeza, Juan
    Celia Garcia-Alvarez-Coque, Maria
    SEPARATIONS, 2021, 8 (04)