Evaluation and comparison of the kinetic performance of ultra-high performance liquid chromatography and high-performance liquid chromatography columns in hydrophilic interaction and reversed-phase liquid chromatography conditions

被引:32
|
作者
Song, Huiying [1 ]
Adams, Erwin [1 ]
Desmet, Gert [2 ]
Cabooter, Deirdre [1 ]
机构
[1] Katholieke Univ Leuven, Dept Pharmaceut & Pharmacol Sci, Leuven, Belgium
[2] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
关键词
HILIC; RPLC; Kinetic plot; Porosity; Flow resistance; PARTICLE-SIZE DISTRIBUTION; SUB-2; MU-M; MASS-SPECTROMETRY; DEAD-VOLUME; SEPARATION; RETENTION; QUANTIFICATION; ADSORPTION; EPHEDRINES; MECHANISM;
D O I
10.1016/j.chroma.2014.10.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An intrinsic performance comparison is made of the reduction in analysis time that can be obtained when switching from HPLC to UHPLC column formats in HILIC and reversed-phase conditions. A detailed overview of the packing characteristics of both stationary phase types is given first. It is demonstrated that HILIC columns demonstrate higher external porosity values than their reversed-phase counterparts resulting in lower flow resistance values. Column total porosity values determined from the elution time of a small marker molecule are shown to depend strongly on the composition of the mobile phase. To omit errors that might arise from an over- or underestimation of the column void time, all plate height and kinetic plot data are therefore expressed as a function of the interstitial velocity. Although only a limited number of columns are evaluated in this study, it is shown that the column efficiency of the HILIC columns is lower than that of their reversed-phase counterparts, at least for the compounds evaluated here. Despite this lower efficiency, the kinetic performance of both stationary phase types is similar, due to the much lower viscosity of the mobile phases typically used in HILIC conditions. Finally, it is demonstrated that a similar, yet slightly larger reduction in analysis time can be obtained when switching from HPLC column formats to UHPLC formats in HILIC compared to reversed-phase conditions. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:83 / 91
页数:9
相关论文
共 50 条
  • [1] A comparison and column selection of Hydrophilic Interaction Liquid Chromatography and Reversed-Phase High-Performance Liquid Chromatography for detection of DNA methylation
    Rastegar, Leila
    Mighani, Hossein
    Ghassempour, Alireza
    ANALYTICAL BIOCHEMISTRY, 2018, 557 : 123 - 130
  • [2] Evaluation of the Kinetic Performance Differences between Hydrophilic-Interaction Liquid Chromatography and Reversed-Phase Liquid Chromatography under Conditions of Identical Packing Structure
    Song, Huiying
    Desmet, Gert
    Cabooter, Deirdre
    ANALYTICAL CHEMISTRY, 2015, 87 (24) : 12331 - 12339
  • [3] Estimation of the phase ratio in reversed-phase high-performance liquid chromatography
    Moldoveanu, Serban
    David, Victor
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1381 : 194 - 201
  • [4] Imidazoline type stationary phase for hydrophilic interaction chromatography and reversed-phase liquid chromatography
    Li, Yuanyuan
    Feng, Yaoyao
    Chen, Tong
    Zhang, Haixia
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (35) : 5987 - 5994
  • [5] Orthogonal method development using hydrophilic interaction chromatography and reversed-phase high-performance liquid chromatography for the determination of pharmaceuticals and impurities
    Wang, XD
    Li, WY
    Rasmussen, HT
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1083 (1-2) : 58 - 62
  • [6] Comparison of various reversed-phase columns for the simultaneous determination of ephedrines in urine by high-performance liquid chromatography
    Imaz, C
    Navajas, R
    Carreras, D
    Rodríguez, C
    Rodríguez, AF
    JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) : 23 - 28
  • [7] UNSUPERVISED CLASSIFICATION OF CHROMATOGRAPHIC COLUMNS IN MICELLAR AND CONVENTIONAL REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Melnikov, A. U.
    Boichenko, A. P.
    Kulikov, A. U.
    Galat, M. N.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (07) : 1016 - 1031
  • [8] Fast Separation of Capsaicinoids from Peppers by Reversed Phase Ultra-Performance Liquid Chromatography: Comparation with Traditional High-Performance Liquid Chromatography Methods
    Barbero, Gerardo F.
    Liazid, Ali
    Ferreiro-Gonzalez, Marta
    Palma, Miguel
    Barroso, Carmelo G.
    INTERNATIONAL JOURNAL OF FOOD PROPERTIES, 2016, 19 (05) : 984 - 992
  • [9] Cholesterol determination in foods: Comparison between high performance and ultra-high performance liquid chromatography
    Albuquerque, Tania Goncalves
    Oliveira, M. Beatriz P. P.
    Sanches-Silva, Ana
    Costa, Helena S.
    FOOD CHEMISTRY, 2016, 193 : 18 - 25
  • [10] The hydrophilic interaction like properties of some reversed phase high performance liquid chromatography columns in the analysis of basic compounds
    Al-Tannak, Naser F.
    Bawazeer, Saud
    Siddiqui, Tahir
    Watson, David G.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (11) : 1486 - 1491