Determination of low levels of benzodiazepines and their metabolites in urine by hollow-fiber liquid-phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS)

被引:63
作者
de Bairros, Andre Valle [1 ,2 ]
de Almeida, Rafael Menck [1 ]
Pantaleao, Lorena [1 ]
Barcellos, Thiago [3 ]
Moura e Silva, Sidnei [3 ]
Yonamine, Mauricio [1 ]
机构
[1] Univ Sao Paulo, Fac Pharmaceut Sci, BR-05508 Sao Paulo, Brazil
[2] Univ Fed Pelotas, Ctr Chem Pharmaceut & Food Sci, Capao Do Leao, Brazil
[3] Univ Caxias Sul, Inst Biotechnol, Caxias Do Sul, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 975卷
基金
巴西圣保罗研究基金会;
关键词
Benzodiazepines; Gas chromatography; Mass spectrometry; Urine; Liquid phase microextraction; Double derivatization; FACILITATED SEXUAL ASSAULT; FORENSIC TOXICOLOGY; SAMPLE PREPARATION; ENZYMATIC-HYDROLYSIS; MAIN METABOLITES; PACKED SORBENT; WHOLE-BLOOD; DRUG; DERIVATIZATION; EXTRACTION;
D O I
10.1016/j.jchromb.2014.10.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, it is shown a method for the determination of benzodiazepines and their main metabolites in urine samples by hollow-fiber liquid-phase microextraction (LPME) in the three-phase mode. Initially, the hydrolysis step was performed using 100 mu L of sodium acetate 2.0 mol/L buffer solution (pH 4.5), 25 mu L of beta-glucuronidase enzyme and incubation for 90 min at 55 degrees C. In parallel with hydrolysis, the LPME fiber (9 cm) was prepared. Its pores were filled with a mixture of dihexyl ether: 1-nonanol (9:1). Afterwards, a solution of 3.0 mol/L of HCl was introduced into the lumen of the fiber (acceptor phase). After hydrolysis, the fiber was submersed in the alkalinized urine (pH 10) containing 10% NaCl. Samples were then submitted to orbital shaking (2400 rpm) for 90 min. The acceptor phase was later withdrawn from the fiber, dried and the residue derivatized with trifluoroacetic anhydride (TFAA) for 10 min at 60 degrees C with further addition of N-methyl-N-tert-butyldimethylsilyltrifluoroacetamide containing 1% tert-butyldimethylchlorosilane (MTBSTFA) for 45 min at 90 degrees C followed by determination by gas chromatography mass spectrometry (GC-MS). The calibration curves obtained showed linearity over the specified range, with a similar sensitivity to traditional techniques and a higher detection capability compared to most of the miniaturized methods described in the literature. The method has been developed and successfully validated and applied to urine samples from real cases of benzodiazepines intake. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:24 / 33
页数:10
相关论文
共 61 条
[1]   Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods [J].
Almeida, AM ;
Castel-Branco, MM ;
Falcao, AC .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (02) :215-222
[2]  
Alves G, 2013, BIOANALYSIS, V5, P1409, DOI [10.4155/BIO.13.92, 10.4155/bio.13.92]
[3]  
Amhard K., 2012, ANAL BIOANAL CHEM, V403, P755
[4]  
[Anonymous], 2009, Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs in Seized Materials and Biological Specimens
[5]   Determination of delorazepam in urine by solid-phase microextraction coupled to high performance liquid chromatography [J].
Aresta, A ;
Monaci, L ;
Zambonin, CG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (05) :965-972
[6]  
Armbruster David A, 2008, Clin Biochem Rev, V29 Suppl 1, pS49
[7]   Role of microextraction sampling procedures in forensic toxicology [J].
Barroso, Mario ;
Moreno, Ivo ;
da Fonseca, Beatriz ;
Queiroz, Joao Antonio ;
Gallardo, Eugenia .
BIOANALYSIS, 2012, 4 (14) :1805-1826
[8]   Toxicological Findings in Cases of Sexual Assault in the Netherlands [J].
Bosman, Ingrid J. ;
Verschraagen, Miranda ;
Lusthof, Klaas J. .
JOURNAL OF FORENSIC SCIENCES, 2011, 56 (06) :1562-1568
[9]   Analysis of exemestane and 17β-hydroxyexemestane in human urine by gas chromatography/mass spectrometry: development and validation of a method using MO-TMS derivatives [J].
Cavalcanti, Gustavo de A. ;
Garrido, Bruno C. ;
Leal, Felipe D. ;
Padilha, Monica C. ;
de la Torre, Xavier ;
Pereira, Henrique M. G. ;
de Aquino Neto, Francisco R. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (22) :3297-3302
[10]   Determination of bromazepam, clonazepam and metabolites after a single intake in urine and hair by LC-MS/MS application to forensic cases of drug facilitated crimes [J].
Chèze, M ;
Villain, M ;
Pépin, G .
FORENSIC SCIENCE INTERNATIONAL, 2004, 145 (2-3) :123-130