Near Infrared Absorption Spectroscopy in Microfluidic Devices With Selectable Pathlength

被引:5
作者
Bello, Valentina [1 ]
Bodo, Elisabetta [1 ]
Merlo, Sabina [1 ]
机构
[1] Univ Pavia, Dept Elect Comp & Biomed Engn, I-27100 Pavia, Italy
关键词
Optical fibers; Glass; Optical reflection; Absorption; Optical fiber sensors; Optical surface waves; Optical variables control; Microfluidics; near infrared; optical absorption; optical sensing; rectangular micro-capillary; spectroscopy; REFLECTION; ETHANOL; FABRICATION; DESIGN; CELL;
D O I
10.1109/JLT.2020.3040488
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work we present a smart micro-opto-fluidic platform based on rectangular-section glass micro-capillaries with integrated reflectors. The micro-opto-fluidic setup was exploited for absorption spectroscopy measurements in the near infrared range from 1.0 to 1.7 mu m. The external flat sides of the micro-capillaries are coated with thin Aluminum layers to create multipath micro-devices in which light can bounce multiple times. Broadband light provided by a Tungsten lamp is coupled into a multimode optical fiber and shone onto the flat surface of the micro-capillary. After travelling inside the micro-channel filled with the sample, radiation is directed towards an optical spectrum analyzer. The line-shape of the output light spectrum depends on the absorption features of the sample and, in particular, on the concentration of water in alcoholic solutions. Experimental results are in good agreement with the prediction given by the developed theoretical model that describes light transmission through the fluidic micro-channel. Moreover, a responsivity parameter, defined as the output power ratio at two wavelengths, is retrieved: water sensitivity is greatly enhanced by the multipath effect since it is proved to be directly proportional to the light bounces in the micro-channel.
引用
收藏
页码:4193 / 4200
页数:8
相关论文
共 33 条
[1]   Measurement of low concentrations of NO2 gas by differential optical absorption spectroscopy method [J].
Al-Jalal, AbdulAziz ;
Al-Basheer, Watheq ;
Gasmi, Khaled ;
Romadhon, Moch S. .
MEASUREMENT, 2019, 146 :613-617
[2]   Novel optical assessments of tissue composition and viability using fluorescence spectroscopy and tissue oxygenation spectrophotometry in patients with systemic sclerosis: a pilot study [J].
Allen, John ;
Di Maria, Costanzo ;
Urwin, Samuel G. ;
Murray, Alan ;
Ottewell, Lesley ;
Griffiths, Bridget .
PHYSIOLOGICAL MEASUREMENT, 2018, 39 (03)
[3]   RETRACTED: A compact photometer based on metal-waveguide-capillary: application to detecting glucose of nanomolar concentration (Retracted Article) [J].
Bai, Min ;
Huang, Hui ;
Hao, Jian ;
Zhang, Ji ;
Wu, Haibo ;
Qu, Bo .
SCIENTIFIC REPORTS, 2015, 5
[4]  
Bello V., 2020, P IEEE INT INSTR MEA, P1
[5]   Spectral Phase Shift Interferometry for Refractive Index Monitoring in Micro-Capillaries [J].
Bello, Valentina ;
Simoni, Alberto ;
Merlo, Sabina .
SENSORS, 2020, 20 (04)
[6]   Micro-opto-fluidic platform for solvents identification based on absorption properties in the NIR region [J].
Bello, Valentina ;
Merlo, Sabina .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (14) :3351-3358
[7]   Effect of Deposition Rate on Structure and Surface Morphology of Thin Evaporated Al Films on Dielectrics and Semiconductors [J].
Bordo, Kirill ;
Rubahn, Horst-Gunter .
MATERIALS SCIENCE-MEDZIAGOTYRA, 2012, 18 (04) :313-317
[8]  
Born M., 1980, PRINCIPLES OPTICS, P180
[9]   Design and fabrication of enhanced polymer waveguide platforms for absorption-based optical chemical sensors [J].
Burke, CS ;
Polerecky, L ;
MacCraith, BD .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (06) :1140-1145
[10]   Refractive Index Sensing in Rectangular Glass Micro-Capillaries by Spectral Reflectivity Measurements [J].
Carpignano, Francesca ;
Rigamonti, Giulia ;
Migliazza, Tommaso ;
Merlo, Sabina .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2016, 22 (03) :383-391