Quantum dot based multiplex fluorescence quenching immune chromatographic strips for the simultaneous determination of sulfonamide and fluoroquinolone residues in chicken samples

被引:23
作者
Hu, Gaoshuang [1 ]
Sheng, Wei [1 ]
Li, Shijie [1 ]
Zhang, Yan [1 ]
Wang, Junping [1 ]
Wang, Shuo [1 ,2 ]
机构
[1] Tianjin Univ Sci & Technol, Minist Educ China, Key Lab Food Nutr & Safety, Tianjin 300457, Peoples R China
[2] BTBU, Beijing Adv Innovat Ctr Food Nutr & Human Hlth, Beijing 100048, Peoples R China
关键词
TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; LINKED-IMMUNOSORBENT-ASSAY; LATERAL-FLOW SENSOR; RAPID DETECTION; WATER SAMPLES; IMMUNOCHROMATOGRAPHIC ASSAY; CAPILLARY-ELECTROPHORESIS; QUANTITATIVE DETECTION; ENVIRONMENTAL WATER;
D O I
10.1039/c7ra01753g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel multiplex fluorescence quenching immune chromatographic strip (FQICS), using quantum dots (QDs) as a fluorescence donor, was proposed to screen sulfonamide (SA) and fluoroquinolone (FQ) residues in chicken samples, simultaneously. The principle of the proposed FQICS is on the basis of the fluorescence quenching effect, and colloidal gold was used as the fluorescence quencher. The limit of detection (LOD) in standard solution was 3 ng mL(-1) and 0.6 ng mL(-1) for sulfaquinoxaline (SQX) and norfloxacin (NOR), respectively, through visual detection using UV. For specificity analysis, results obtained indicated that this established method could be applied in broad-spectrum detection of SAs and FQs. Then the proposed FQICS was successfully applied in semiquantitative analysis of SQX (30 mu g kg(-1)) and NOR (6 mu g kg(-1)) in spiked chicken samples. The results obtained using the strips showed great agreement with those obtained using an ELISA kit, which indicates the good accuracy of the strips. As a conclusion, the proposed FQICS with a signal "turn-on" mode provides a suitable immunoassay for rapid, sensitive and simultaneous screening of SAs and FQs in chicken samples on-site.
引用
收藏
页码:31123 / 31128
页数:6
相关论文
共 38 条
[1]   Generation of Broad Specificity Antibodies for Sulfonamide Antibiotics and Development of an Enzyme-Linked Immunosorbent Assay (ELISA) for the Analysis of Milk Samples [J].
Adrian, Javier ;
Font, Hector ;
Diserens, Jean-Marc ;
Sanchez-Baeza, Francisco ;
Marco, M. -Pilar .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (02) :385-394
[2]   Detection of norfloxacin and monitoring its effect on caffeine catabolism in urine samples [J].
Agrawal, Bharati ;
Chandra, Pranjal ;
Goyal, Rajendra N. ;
Shim, Yoon-Bo .
BIOSENSORS & BIOELECTRONICS, 2013, 47 :307-312
[3]   Antigen detection based on background fluorescence quenching immunochromatographic assay [J].
Chen, Xiangjun ;
Xu, Yangyang ;
Yu, Jinsheng ;
Li, Jiutong ;
Zhou, Xuelei ;
Wu, Chuanyong ;
Ji, Qiuliang ;
Ren, Yuan ;
Wang, Liqun ;
Huang, Zhengyi ;
Zhuang, Hanling ;
Piao, Long ;
Head, Richard ;
Wang, Yajie ;
Lou, Jiatao .
ANALYTICA CHIMICA ACTA, 2014, 841 :44-50
[4]   Near-infrared fluorescence-based multiplex lateral flow immunoassay for the simultaneous detection of four antibiotic residue families in milk [J].
Chen, Yiqiang ;
Chen, Qian ;
Han, Miaomiao ;
Liu, Jiangyang ;
Zhao, Peng ;
He, Lidong ;
Zhang, Yuan ;
Niu, Yiming ;
Yang, Wenjun ;
Zhang, Liying .
BIOSENSORS & BIOELECTRONICS, 2016, 79 :430-434
[5]   Determination of norfloxacin in rat liver perfusate using capillary electrophoresis with laser-induced fluorescence detection [J].
Cheng, Ching-Ling ;
Fu, Chia-Hung ;
Chou, Chen-Hsi .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2) :381-385
[6]   Simultaneous determination of fluoroquinolones in environmental water by liquid chromatography-tandem mass spectrometry with direct injection: A green approach [J].
Denadai, Marina ;
Cass, Quezia Bezerra .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1418 :177-184
[7]   Development of a novel dual-functional lateral-flow sensor for on-site detection of small molecule analytes [J].
Fu, Qiangqiang ;
Liang, Jiajie ;
Lan, Caifeng ;
Zhou, Kenan ;
Shi, Congying ;
Tang, Yong .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 :683-689
[8]   A novel fluorescence-quenching immunochromatographic sensor for detection of the heavy metal chromium [J].
Fu, QiangQiang ;
Tang, Yong ;
Shi, CongYing ;
Zhang, XiaoLi ;
Xiang, JunJian ;
Liu, Xi .
BIOSENSORS & BIOELECTRONICS, 2013, 49 :399-402
[9]   A sensitive and semi-quantitative method for determination of multi-drug residues in animal body fluids using multiplex dipstick immunoassay [J].
Han, Shuaijuan ;
Zhou, Tianjiao ;
Yin, Bingjie ;
He, Pingli .
ANALYTICA CHIMICA ACTA, 2016, 927 :64-71
[10]   Upconversion Nanoparticles and Monodispersed Magnetic Polystyrene Microsphere Based Fluorescence Immunoassay for the Detection of Sulfaquinoxaline in Animal-Derived Foods [J].
Hu, Gaoshuang ;
Sheng, Wei ;
Zhang, Yan ;
Wang, Junping ;
Wu, Xuening ;
Wang, Shuo .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (19) :3908-3915