Evaluation of Printed P(VDF-TrFE) Pressure Sensor Signal Quality in Arterial Pulse Wave Measurement

被引:16
作者
Laurila, Mika-Matti [1 ]
Peltokangas, Mikko [2 ]
Montero, Karem Lozano [1 ]
Siponkoski, Tuomo [3 ]
Juuti, Jari [3 ]
Tuukkanen, Sampo [2 ]
Oksala, Niku [2 ,4 ,5 ]
Vehkaoja, Antti [2 ]
Mantysalo, Matti [1 ]
机构
[1] Tampere Univ, Fac Informat Technol & Commun Sci, Tampere 33720, Finland
[2] Tampere Univ, Fac Med & Hlth Technol, Tampere 33720, Finland
[3] Univ Oulu, Microelect Res Unit, Oulu 90014, Finland
[4] Tampere Univ Hosp, Ctr Vasc Surg & Intervent Radiol, Tampere 33521, Finland
[5] Finnish Cardiovasc Res Ctr, Tampere 33521, Finland
基金
芬兰科学院;
关键词
Printed electronics; pulse wave measurement; radial artery; piezoelectric dynamic pressure sensor; P(VDF-TrFE); electret material; EMFi; SENSITIVITY; PERFORMANCE; ELECTRODE;
D O I
10.1109/JSEN.2019.2934943
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this contribution, we evaluate the performance of an additively fabricated piezoelectric poly(vinylidenefluoride-co-trifluoroethylene) (P(VDF-TrFE)) based dynamic pressure sensor in non-invasive arterial pulse wave (PW) measurement. Additively fabricated piezoelectric sensors have high potential for the realization of affordable and unobtrusive PW measurement systems which could enable the long-term monitoring of patients with cardiovascular diseases (CVDs). However, the accuracy and reliability of such sensors have not been extensively studied before. We propose an additive fabrication process for a P(VDF-TrFE) PW-sensor, measure PW from the radial artery at the wrist from 22 healthy volunteer subjects, calculate clinically relevant parameters based on the PW waveform and compare their values to the values obtained from concurrent measurement with an electromechanical film (EMFi) based reference sensor, used earlier in several clinical studies. We show that the signals recorded with the two sensors, as well as the radial augmentation index (rAIx) and the stiffness index (SI) calculated from them, are in good agreement with each other. These results demonstrate that the additively fabricated P(VDF-TrFE) PW sensors can reach a suitable level of accuracy and reliability for clinical use.
引用
收藏
页码:11072 / 11080
页数:9
相关论文
共 39 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] High-Performance Piezoelectric Nanogenerators with Imprinted P(VDF-TrFE)/BaTiO3 Nanocomposite Micropillars for Self-Powered Flexible Sensors
    Chen, Xiaoliang
    Li, Xiangming
    Shao, Jinyou
    An, Ningli
    Tian, Hongmiao
    Wang, Chao
    Han, Tianyi
    Wang, Li
    Lu, Bingheng
    [J]. SMALL, 2017, 13 (23)
  • [3] A high performance P(VDF-TrFE) nanogenerator with self-connected and vertically integrated fibers by patterned EHD pulling
    Chen, Xiaoliang
    Tian, Hongmiao
    Li, Xiangming
    Shao, Jinyou
    Ding, Yucheng
    An, Ningli
    Zhou, Yaopei
    [J]. NANOSCALE, 2015, 7 (27) : 11536 - 11544
  • [4] Damjanovic D., 2005, SCI HYSTERESIS, P431
  • [5] Structure and functional properties of ferroelectric polymers
    Furukawa, T
    [J]. ADVANCES IN COLLOID AND INTERFACE SCIENCE, 1997, 71-2 : 183 - 208
  • [6] A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
    Gong, Shu
    Schwalb, Willem
    Wang, Yongwei
    Chen, Yi
    Tang, Yue
    Si, Jye
    Shirinzadeh, Bijan
    Cheng, Wenlong
    [J]. NATURE COMMUNICATIONS, 2014, 5
  • [7] Epidermal Electronics
    Kim, Dae-Hyeong
    Lu, Nanshu
    Ma, Rui
    Kim, Yun-Soung
    Kim, Rak-Hwan
    Wang, Shuodao
    Wu, Jian
    Won, Sang Min
    Tao, Hu
    Islam, Ahmad
    Yu, Ki Jun
    Kim, Tae-il
    Chowdhury, Raeed
    Ying, Ming
    Xu, Lizhi
    Li, Ming
    Chung, Hyun-Joong
    Keum, Hohyun
    McCormick, Martin
    Liu, Ping
    Zhang, Yong-Wei
    Omenetto, Fiorenzo G.
    Huang, Yonggang
    Coleman, Todd
    Rogers, John A.
    [J]. SCIENCE, 2011, 333 (6044) : 838 - 843
  • [8] Low-voltage, high-sensitivity and high-reliability bimodal sensor array with fully inkjet-printed flexible conducting electrode for low power consumption electronic skin
    Kim, Kyungkwan
    Jung, Minhyun
    Kim, Bumjin
    Kim, Jihoon
    Shin, Kwanwoo
    Kwon, Oh-Sun
    Jeon, Sanghun
    [J]. NANO ENERGY, 2017, 41 : 301 - 307
  • [9] Radial augmentation index: A useful and easily obtainable parameter for vascular aging
    Kohara, K
    Tabara, Y
    Oshiumi, A
    Miyawaki, Y
    Kobayashi, T
    Miki, T
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (01) : 11S - 14S
  • [10] A Fully Printed Ultra-Thin Charge Amplifier for On-Skin Biosignal Measurements
    Laurila, Mika-Matti
    Matsui, Hiroyuki
    Shiwaku, Rei
    Peltokangas, Mikko
    Verho, Jarmo
    Montero, Karem Lozano
    Sekine, Tomohito
    Vehkaoja, Antti
    Oksala, Niku
    Tokito, Shizuo
    Mantysalo, Matti
    [J]. IEEE JOURNAL OF THE ELECTRON DEVICES SOCIETY, 2019, 7 (01) : 566 - 574