Measurement of coronary collateral flow and resistance in the presence of an open critical stenosis, and the response to intra-arterial thrombosis

被引:5
作者
Mansaray, M
Hynd, JW
Vergroesen, I
Belcher, PR
Drake-Holland, AJ
Noble, MIM
机构
[1] Univ London Imperial Coll Sci Technol & Med, Charing Cross Hosp, Natl Heart & Lung Inst, Dept Cardiovasc Med, London W6 8RF, England
[2] Univ Amsterdam, Acad Med Ctr, Dept Med Phys, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Glasgow, Royal Infirm, Dept Cardiothorac Surg, Glasgow G12 8QQ, Lanark, Scotland
关键词
blood flow; collateral circulation; coronary circulation; ischemia; platelets; thrombosis/embolism; vasoconstriction/dilation;
D O I
10.1016/S0008-6363(00)00109-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: (1) Can one measure coronary collateral flow around an open critical stenosis? (2) Does intracoronary platelet thrombosis affect native coronary collateral vessels? Methods: We measured regional myocardial blood flow by the radioactive microsphere technique in seven anaesthetised dogs with an ultrasonic flowmeter on the circumflex branch of the left coronary artery (LCx). Measurements were made (a) in a control period. (b) after induction of a tight stenosis on the LCx, and (c) after additional arterial damage at the stenosis to induce intraluminal thrombosis. Collateral flow was calculated from LCx tissue flow(in ml/min/g tissue) minus LCx flowmeter flow which is in ml/min. Therefore, it was necessary to use scaling by reference back to the control measurements and conversion to ml/min/g tissue equivalent. Results: LCx stenosis induced collateral Row from the other coronary arteries into the LCx area of supply, which decreased (mean+/-S.E.) from 0.23+/-0.03 to 0.15+/-0.05 ml/min/g tissue with thrombosis. Collateral resistance correspondingly increased with thrombosis from 187.6+/-18.2 to 1069+/-544 mmHg/ml/min/g (P<0.02). Conclusion: Coronary collateral Row around an open stenosis can be measured by reference back to control conditions. The coronary collaterals vasoconstrict in the presence of thombosis even though they are in the stream of blood coming from normal coronary arteries. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:359 / 366
页数:8
相关论文
共 33 条
[1]  
[Anonymous], 1985, CORONARY COLLATERALS
[2]  
Belcher PR, 1995, CARDIOVASC RES, V30, P807
[3]   ANATOMY OF VENTRICULAR CORONARY ARTERIES IN DOG [J].
BLAIR, E .
CIRCULATION RESEARCH, 1961, 9 (02) :333-&
[4]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[5]  
COHEN MV, 1978, AM J PHYSIOL, V229, P537
[6]   TOTAL AND REGIONAL CORONARY BLOOD FLOW MEASURED BY RADIOACTIVE MICROSPHERES IN CONSCIOUS AND ANESTHETIZED DOGS [J].
DOMENECH, RJ ;
HOFFMAN, JIE ;
NOBLE, MIM ;
SAUNDERS, KB ;
HENSON, JR ;
SUBIJANTO, S .
CIRCULATION RESEARCH, 1969, 25 (05) :581-+
[7]   DIRECT MEASUREMENT OF CORONARY COLLATERAL BLOOD-FLOW IN CONSCIOUS DOGS BY AN ELECTROMAGNETIC FLOWMETER [J].
ELLIOT, EC ;
KHOURI, EM ;
SNOW, JA ;
GREGG, DE .
CIRCULATION RESEARCH, 1974, 34 (03) :374-383
[8]  
EULER DE, 1995, CARDIOVASC RES, V29, P33
[9]   EFFECT OF CORONARY VASODILATOR DRUGS ON RETROGRADE FLOW IN AREAS OF CHRONIC MYOCARDIAL ISCHEMIA [J].
FAM, WM ;
MCGREGOR, M .
CIRCULATION RESEARCH, 1964, 15 (04) :355-&
[10]   BLOOD-FLOW REDUCTIONS IN STENOSED CANINE CORONARY-ARTERIES - VASOSPASM OR PLATELET-AGGREGATION [J].
FOLTS, JD ;
GALLAGHER, K ;
ROWE, GG .
CIRCULATION, 1982, 65 (02) :248-255