Production of thin shell clavicle implants through Single Point Incremental Forming

被引:41
作者
Vanhove, Hans [1 ]
Carette, Yannick [1 ]
Vancleef, Sanne [1 ]
Duflou, Joost R. [1 ]
机构
[1] Katholieke Univ Leuven, Dept Mech Engn, Celestijnenelaan 300B, B-3001 Leuven, Belgium
来源
17TH INTERNATIONAL CONFERENCE ON SHEET METAL (SHEMET17) | 2017年 / 183卷
关键词
SPIF; implant; clavicle; accuracy; design; FRACTURES;
D O I
10.1016/j.proeng.2017.04.058
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The expanding demand for discrete freeform parts in bio-medical applications emphasizes the need for flexible production processes like Single Point Incremental Forming. This paper presents the specific challenges encountered during the design and fabrication of clavicle implants using medical grade titanium sheets. The fracture fixation and bone aligning task of these implants call for specific accuracy distribution, while the distinct geometry and post forming heat treatment influence production accuracy. The design potential for these implants considering forming angles of titanium grade 2 and soft tissue interactions are discussed. A generic case for the design, forming, heat treatment and trimming of a Titanium clavicle fixation plate is presented. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 10 条
[1]   Single point incremental forming of a facial implant [J].
Araujo, Rogerio ;
Teixeira, Pedro ;
Montanari, Luciana ;
Reis, Ana ;
Silva, Maria B. ;
Martins, Paulo A. F. .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2014, 38 (05) :369-378
[2]   Strategies to improve the geometric accuracy in asymmetric single point incremental forming [J].
Bambach, M. ;
Araghi, B. Taleb ;
Hirt, G. .
PRODUCTION ENGINEERING-RESEARCH AND DEVELOPMENT, 2009, 3 (02) :145-156
[3]  
Duflou J., 2005, CUSTOMISED MEDICAL I, P217
[4]   Manufacture of Accurate Titanium Cranio-Facial Implants with High Forming Angle Using Single Point Incremental Forming [J].
Duflou, Joost R. ;
Behera, Amar Kumar ;
Vanhove, Hans ;
Bertol, Liciane S. .
SHEET METAL 2013, 2013, 549 :223-+
[5]  
Fiorentino A., 2012, INT J MECHATRONICS M, V5, P36, DOI [10.1504/IJMMS.2012.046146, DOI 10.1504/IJMMS.2012.046146]
[6]   Tool and lubrication for negative incremental forming of a commercially pure titanium sheet [J].
Hussain, G. ;
Gao, L. ;
Hayat, N. ;
Cui, Z. ;
Pang, Y. C. ;
Dar, N. U. .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2008, 203 (1-3) :193-201
[7]   Trends in the Incidence of Clavicle Fractures and Surgical Repair in Sweden: 2001-2012 [J].
Huttunen, Tuomas T. ;
Launonen, Antti P. ;
Berg, Hans E. ;
Lepola, Vesa ;
Fellander-Tsai, Li ;
Mattila, Ville M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (21) :1837-1842
[8]   Titanium based cranial reconstruction using incremental sheet forming [J].
Lu, B. ;
Ou, H. ;
Shi, S. Q. ;
Long, H. ;
Chen, J. .
INTERNATIONAL JOURNAL OF MATERIAL FORMING, 2016, 9 (03) :361-370
[9]  
Piccininni A, 2016, BIOMEDICAL TITANIUM, P15007, DOI [10.1051/matecconf/201, DOI 10.1051/MATECCONF/201]
[10]   Systematic review of the complications of plate fixation of clavicle fractures [J].
Wijdicks, Frans-Jasper G. ;
Van der Meijden, Olivier A. J. ;
Millett, Peter J. ;
Verleisdonk, Egbert J. M. M. ;
Houwert, R. Marijn .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (05) :617-625