In vitro examination of the coronary artery wall after balloon angioplasty using intracoronary ultrasound

被引:2
作者
Voigtländer, T [1 ]
Rupprecht, HJ
Britten, M
Stähr, P
Nowak, B
Otto, M
Kirkpatrick, CJ
Brennecke, R
Meyer, J
机构
[1] Johannes Gutenberg Univ Mainz, Med Clin 2, D-55101 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Inst Pathol, D-55101 Mainz, Germany
来源
INTERNATIONAL JOURNAL OF CARDIAC IMAGING | 1998年 / 14卷 / 01期
关键词
intracoronary ultrasound; balloon angioplasty; in vitro;
D O I
10.1023/A:1005846615032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
After autopsy 12 human coronary arteries were investigated by intracoronary ultrasound in order to measure the vessel wall dimensions and to detect damage on the vessel wall architecture after balloon angioplasty. Histology revealed artherosclerosis in 11/12 arteries. A total of 41 representative coronary segments were selected for further off-line ultrasound and histological analysis. Intracoronary ultrasound and histological measurements of the vessel wall thickness after balloon dilatation demonstrated a good correlation between the maximum thickness of the intima (histology 0.62 mm vs. intracoronary ultrasound 0.65 mm, r = 0.87) and the intima-media complex (0.80 mm vs. 0.83 mm, r = 0.87), in contrast to a weak one between the minimum thickness (r = 0.46 and r = 0.37). A total of 21 cases of damage occurred during angioplasty; intracoronary ultrasound detected 17. Further analysis showed that it imaged 10 of 11 cases of damage involving more than 30 degrees of the vessel circumference and 7 of 10 cases of damage involving less than 30 degrees of the vessel circumference. After balloon angioplasty of diseased coronary arteries, intracoronary ultrasound is therefore reliable in measuring the maximum wall thickness and in imaging damage involving more than 30 degrees of the vessel wall circumference.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 16 条
[1]   INTRAVASCULAR ULTRASOUND IMAGING OF CORONARY-ARTERIES - IS 3 LAYERS THE NORM [J].
FITZGERALD, PJ ;
STGOAR, FG ;
CONNOLLY, AJ ;
PINTO, FJ ;
BILLINGHAM, ME ;
POPP, RL ;
YOCK, PG .
CIRCULATION, 1992, 86 (01) :154-158
[2]   INTRAVASCULAR ULTRASOUND IMAGING OF ARTERIAL-WALL ARCHITECTURE [J].
GE, J ;
ERBEL, R ;
GORGE, G ;
GERBER, T ;
BRENNECKE, R ;
SEIDEL, I ;
REICHERT, T ;
MEYER, J .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1992, 9 (05) :475-483
[3]   CLASSIFICATION OF MORPHOLOGIC EFFECTS OF PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY ASSESSED BY INTRAVASCULAR ULTRASOUND [J].
GERBER, TC ;
ERBEL, R ;
GORGE, G ;
GE, J ;
RUPPRECHT, HJ ;
MEYER, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (20) :1546-1554
[4]   ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY [J].
GUSSENHOVEN, EJ ;
ESSED, CE ;
LANCEE, CT ;
MASTIK, F ;
FRIETMAN, P ;
VANEGMOND, FC ;
REIBER, J ;
BOSCH, H ;
VANURK, H ;
ROELANDT, J ;
BOM, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) :947-952
[5]  
GUSSENHOVEN EJ, 1993, DEV CARDIOVASC MED, V143, P45
[6]   REAL-TIME INTRAVASCULAR ULTRASONIC-IMAGING BEFORE AND AFTER BALLOON ANGIOPLASTY [J].
GUSSENHOVEN, EJ ;
THE, SHK ;
GERRITSEN, P ;
VANURK, H ;
LI, WG ;
VANEGMOND, FC ;
ROELANDT, JRTC ;
LANCEE, CT ;
BOM, N .
JOURNAL OF CLINICAL ULTRASOUND, 1991, 19 (05) :294-297
[7]   MORPHOLOGICAL EFFECTS OF CORONARY BALLOON ANGIOPLASTY INVIVO ASSESSED BY INTRAVASCULAR ULTRASOUND IMAGING [J].
HONYE, J ;
MAHON, DJ ;
JAIN, A ;
WHITE, CJ ;
RAMEE, SR ;
WALLIS, JB ;
ALZARKA, A ;
TOBIS, JM .
CIRCULATION, 1992, 85 (03) :1012-1025
[8]  
Kearney P, 1996, EUR HEART J, V17, P721
[9]  
KRASS S, 1994, COMPUT CARDIOL, P289
[10]   INTRAVASCULAR ULTRASOUND IMAGING - INVITRO VALIDATION AND PATHOLOGICAL CORRELATION [J].
NISHIMURA, RA ;
EDWARDS, WD ;
WARNES, CA ;
REEDER, GS ;
HOLMES, DR ;
TAJIK, AJ ;
YOCK, PG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) :145-154