Paediatric diagnostic reference levels in computed tomography: a systematic review

被引:15
作者
Satharasinghe, D. M. [1 ,2 ]
Jeyasugiththan, J. [1 ]
Wanninayake, W. M. N. M. B. [2 ]
Pallewatte, A. S. [3 ]
机构
[1] Univ Colombo, Dept Nucl Sci, Colombo, Sri Lanka
[2] Horizon Campus, Malabe, Sri Lanka
[3] Natl Hosp Sri Lanka, Dept Radiol, Colombo, Sri Lanka
关键词
pediatric DRL; dose reference level; diagnostic reference level; computed tomography; DRL;
D O I
10.1088/1361-6498/abd840
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aims to review the existing literature on diagnostic reference levels (DRLs) in paediatric computed tomography (CT) procedures and the methodologies for establishing them. A comprehensive literature search was done in the popular databases such as PubMed and Google Scholar under the key words 'p(a)ediatric DRL', 'dose reference level', 'diagnostic reference level' and 'DRL'. Twenty-three articles originating from 15 countries were included. Differences were found in the methods used to establish paediatric CT DRLs across the world, including test subjects, reference phantom size, anatomical regions, modes of data collection and stratification techniques. The majority of the studies were based on retrospective patient surveys. The head, chest and abdomen were the common regions. The volume computed tomography dose index (CTDIvol) and dose-length product (DLP) were the dosimetric quantities chosen in the majority of publications. However, the size-specific dose estimate was a growing trend in the DRL concept of CT. A 16 cm diameter phantom was used by most of the publications when defining DRLs for head, chest and abdomen. The majority of the DRLs were given based on patient age, and the common age categories for head, chest and abdomen regions were 0-1, 1-5, 5-10 and 10-15 years. The DRL ranges for the head region were 18-68 mGy (CTDIvol) and 260-1608 mGy cm (DLP). For chest and abdomen regions the variations were 1.0-15.6 mGy, 10-496 mGy cm and 1.8-23 mGy, 65-807 mGy cm, respectively. All these DRLs were established for children aged 0-18 years. The wide range of DRL distributions in chest and abdomen regions can be attributed to the use of two different reference phantom sizes (16 and 32 cm), failure to follow a common methodology and inadequate dose optimisation actions. Therefore, an internationally accepted protocol should be followed when establishing DRLs. Moreover, these DRL variations suggest the importance of establish a national DRL for each country considering advanced techniques and dose reduction methodologies.
引用
收藏
页码:R1 / R27
页数:27
相关论文
共 43 条
[1]   Survey of paediatric imaging exposure from computed tomography examinations [J].
Alkhorayef, M. .
RADIATION PHYSICS AND CHEMISTRY, 2020, 167
[2]  
[Anonymous], 1996, ICRP PUBL
[3]  
[Anonymous], 1962, REPORT UN SCI COMMIT
[4]  
[Anonymous], 2001, ICRP PUBL
[5]   Patient doses from CT examinations in Turkey [J].
Atac, Gokce Kaan ;
Parmaksiz, Aydin ;
Inal, Tolga ;
Bulur, Emine ;
Bulgurlu, Figen ;
Oncu, Tolga ;
Gundogdu, Sadi .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2015, 21 (05) :428-434
[6]   RADIATION DOSE DETERMINATION IN ABDOMINAL CT EXAMINATIONS OF CHILDREN AT SUDANESE HOSPITALS USING SIZE-SPECIFIC DOSE ESTIMATES [J].
Bashier, Einas H. ;
Suliman, I. I. .
RADIATION PROTECTION DOSIMETRY, 2019, 183 (04) :444-449
[7]   Diagnostic reference levels of paediatric computed tomography examinations performed at a dedicated Australian paediatric hospital [J].
Bibbo, Giovanni ;
Brown, Scott ;
Linke, Rebecca .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) :475-484
[8]  
Boone J, 2011, AAPM report No. 204: size-specific dose estimates (SSDE) in pediatric and adult body CT examinations
[9]   Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 2: plain radiography and diagnostic fluoroscopy [J].
Celier, David ;
Roch, Patrice ;
Etard, Cecile ;
Ducou Le Pointe, Hubert ;
Brisse, Herve J. .
EUROPEAN RADIOLOGY, 2020, 30 (02) :1182-1190
[10]  
EC: Directorate-General for Energy, 2018, Radiation Protection N 185, DOI [10.2833/486256., DOI 10.2833/486256]