Combined EEG and MEG analysis of early somatosensory evoked activity in children and adolescents with focal epilepsies

被引:31
作者
Bast, T. [1 ]
Wright, T.
Boor, R.
Harting, I.
Feneberg, R.
Rupp, A.
Hoechstetter, K.
Rating, D.
Baumgaertner, U.
机构
[1] Univ Childrens Hosp, Dept Pediat Neurol, INF 150, D-69120 Heidelberg, Germany
[2] Univ Kiel, Dept Pediat Neurol, Raisdorf, Germany
[3] Univ Hosp, Dept Neuroradiol, Heidelberg, Germany
[4] Heidelberg Univ, Pediat Unit, Coordinat Ctr Clin Trials, KKS, D-6900 Heidelberg, Germany
[5] Univ Hosp, Dept Neurol, Heidelberg, Germany
[6] MEGIS Software GmbH, Graefelfing, Germany
[7] Johannes Gutenberg Univ Mainz, Inst Physiol & Pathophysiol, D-6500 Mainz, Germany
关键词
SEP; SEF; source analysis; somatosensory cortex; epilepsy;
D O I
10.1016/j.clinph.2007.03.037
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: The study aimed to evaluate differences between EEG and MEG analysis of early somatosensory evoked activity in patients with focal epilepsies in localizing eloquent areas of the somatosensory cortex. Methods: Twenty-five patients (12 male, 13 female; age 4-25 years, mean 11.7 years) were included. Syndromes were classified as symptomatic in 17, idiopathic in 2 and cryptogenic in 6 cases. 10 patients presented with malformations of cortical development (MCD). 122 channel MEG and simultaneous 33-channel EEG were recorded during tactile stimulation of the thumb (sampling rate 769 Hz, band-pass 0.3-260 Hz). Forty-four hemispheres were analyzed. Hemispheres were classified as type 1: normal (15), 11: central structural lesion (16), 111: no lesion, but central epileptic discharges (ED, 8), IV: lesion or ED outside the central region (5). Analysis of both sides including one normal and one type II or III hemisphere was possible in 15 patients. Recordings were repeated in 18 hemispheres overall. Averaged data segments were filtered (10-250 Hz) and analyzed off-line with BESA. Latencies and amplitudes of N20 and P30 were analyzed. A regional source was fitted for localizing S1 by MRI co-registration. Orientation of EEG N20 was calculated from a single dipole model. Results: EEG and MEG lead to comparable good results in all normal hemispheres. Only EEG detected N20/P30 in 3 hemispheres of types II/III while MEG showed no signal. N20 dipoles had a more radial orientation in these cases. MEG added information in one hemisphere, when EEG source analysis of a clear N20 was not possible because of a low signal-to-noise ratio. Overall N20 dipoles had a more radial orientation in type 11 when compared to type I hemispheres (p = 0.01). Further N20/P30 parameters (amplitudes, latencies, localization related to central sulcus) showed no significant differences between affected and normal hemispheres. Early somatosensory evoked activity was preserved within the visible lesion in 5 of the 10 patients with MCD. Conclusions: MEG should be combined with EEG when analyzing tactile evoked activities in hemispheres with a central structural lesion or ED focus. Significance: At time, MEG analysis is frequently applied without simultaneous EEG. Our results clearly show that EEG may be superior under specific circumstances and combination is necessary when analyzing activity from anatomically altered cortex. (c) 2007 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1721 / 1735
页数:15
相关论文
共 53 条
  • [21] FUNCTIONAL-ORGANIZATION OF THE HUMAN 1ST AND 2ND SOMATOSENSORY CORTICES - A NEUROMAGNETIC STUDY
    HARI, R
    KARHU, J
    HAMALAINEN, M
    KNUUTILA, J
    SALONEN, O
    SAMS, M
    VILKMAN, V
    [J]. EUROPEAN JOURNAL OF NEUROSCIENCE, 1993, 5 (06) : 724 - 734
  • [22] Dynamic activation of distinct cytoarchitectonic areas of the human S1 cortex after median nerve stimulation
    Hashimoto, I
    Kimura, T
    Iguchi, Y
    Takino, T
    Sekihara, K
    [J]. NEUROREPORT, 2001, 12 (09) : 1891 - 1897
  • [23] Magnetic source imaging of tactile input shows task-independent attention effects in SII
    Hoechstetter, K
    Rupp, A
    Meinck, HM
    Weckesser, D
    Bornfleth, H
    Stippich, C
    Berg, P
    Scherg, M
    [J]. NEUROREPORT, 2000, 11 (11) : 2461 - 2465
  • [24] Interaction of tactile input in the human primary and secondary somatosensory cortex -: A magnetoencephalographic study
    Hoechstetter, K
    Rupp, A
    Stancák, A
    Meinck, HM
    Stippich, C
    Berg, P
    Scherg, M
    [J]. NEUROIMAGE, 2001, 14 (03) : 759 - 767
  • [25] Abnormal primary somatosensory function in unilateral polymicrogyria: an MEG study
    Ishitobi, M
    Nakasato, N
    Yoshimoto, T
    Iinuma, K
    [J]. BRAIN & DEVELOPMENT, 2005, 27 (01) : 22 - 29
  • [26] Detection of epileptiform activity by human interpreters:: Blinded comparison between electroencephalography and magnetoencephalography
    Iwasaki, M
    Pestana, E
    Burgess, RC
    Lüders, HO
    Shamoto, T
    Nakasato, T
    [J]. EPILEPSIA, 2005, 46 (01) : 59 - 68
  • [27] Functional organization of the brain with malformations of cortical development
    Janszky, J
    Ebner, A
    Kruse, B
    Mertens, M
    Jokeit, H
    Seitz, RJ
    Witte, OW
    Tuxhorn, I
    Woermann, FG
    [J]. ANNALS OF NEUROLOGY, 2003, 53 (06) : 759 - 767
  • [28] TACTILE SENSIBILITY IN THE HUMAN HAND - RELATIVE AND ABSOLUTE DENSITIES OF 4 TYPES OF MECHANORECEPTIVE UNITS IN GLABROUS SKIN
    JOHANSSON, RS
    VALLBO, AB
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1979, 286 (JAN): : 283 - 300
  • [29] Asymmetry in the human primary somatosensory cortex and handedness
    Jung, P
    Baumgärtner, U
    Bauermann, T
    Magerl, W
    Gawehn, J
    Stoeter, P
    Treede, RD
    [J]. NEUROIMAGE, 2003, 19 (03) : 913 - 923
  • [30] EEG minimum-norm estimation compared with MEG dipole fitting in the localization of somatosensory sources at S1
    Komssi, S
    Huttunen, J
    Aronen, HJ
    Ilmoniemi, RJ
    [J]. CLINICAL NEUROPHYSIOLOGY, 2004, 115 (03) : 534 - 542