Recovery of EDTA from power plant boiler chemical cleaning wastewater

被引:29
|
作者
Huang, CP [1 ]
Hsu, MC
Miller, P
机构
[1] Univ Delaware, Dept Civil & Environm Engn, Newark, DE 19716 USA
[2] Univ Delaware, Dept Civil & Environm Engn, Newark, DE USA
[3] Maryland Dept Nat Resour, Monitoring & Non Tidal Assessment Div, Annapolis, MD USA
来源
关键词
Acetic acid - Boiler corrosion - Chelation - Cleaning - Copper - Current density - Electrolysis - Impurities - Iron oxides - Positive ions - Reduction - Thermal effects;
D O I
10.1061/(ASCE)0733-9372(2000)126:10(919)
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The deposition of iron oxides, metallic copper, and other impurities on boiler tube surfaces causes loss of heat transfer efficiency at electrical power plants. Hence, the tubes are cleaned every 3-5 years in order to restore the heat transfer efficiency. Chelating agents, mainly ethylenediaminetetraacetate (EDTA) and its salts, have been extensively used for the removal of metal deposits from the boiler tube surfaces. Consequently, the boiler chemical cleaning wastewater (BCCW) contains large amounts of iron, copper, and chelating agents. An electrochemical reduction process that reduces metal ions to their elemental state is tested and evaluated in order to provide the potential option to recover EDTA for reuse from power plant BCCW. Results from controlled direct current electrolysis experiments show that the electroreduction process can successfully remove metal ions from the synthetic solution and field BCCW samples and can deposit elemental metals on the cathodic plate. At a current density of 15.5 mA/cm(2) and a temperature of 40 degrees C, the percentage metal removal and current efficiency were 94.16 and 8.27%, respectively, with a cadmium cathodic plate, Moreover, results also indicate that the percentage of metal removal and overall current efficiency increase with increasing current density and temperature under the optimal condition (15.5 mA/cm(2) and 40 degrees C). The electroreduction process is able to separate metal ions from their EDTA complexes. The free EDTA can be recovered from field power plant BCCW and be reused again as cleaning agent.
引用
收藏
页码:919 / 924
页数:6
相关论文
共 50 条
  • [21] Comparative analysis of a dual Kalina cycle configuration for heat recovery from boiler stack in a steam power plant
    Shahrokhi, Mahmoud Reza
    Ozgoli, Hassan Ali
    Farhani, Foad
    Environmental Progress and Sustainable Energy, 2022, 41 (06):
  • [22] Comparative analysis of a dual Kalina cycle configuration for heat recovery from boiler stack in a steam power plant
    Shahrokhi, Mahmoud Reza
    Ozgoli, Hassan Ali
    Farhani, Foad
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2022, 41 (06)
  • [23] CONTRACT CLEANING OF CHEMICAL PLANT
    OWEN, GP
    CHEMISTRY & INDUSTRY, 1971, (48) : 1376 - &
  • [24] Experiences from the boiler plant in the large power station of Bohlen
    Zeuner
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1931, 75 : 309 - 316
  • [25] Potential For Energy Recovery From A Wastewater Treatment Plant
    Caceres, E.
    Alca, J. J.
    IEEE LATIN AMERICA TRANSACTIONS, 2016, 14 (07) : 3316 - 3321
  • [26] CURRENT TECHNOLOGY FOR POWER PLANT MAKEUP WATER TREATMENT AND WASTEWATER RECOVERY
    Buecker, Brad
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 5, 2012, : 839 - 845
  • [27] Insight into chemical phosphate recovery from municipal wastewater
    Ye, Yuanyao
    Ngo, Huu Hao
    Guo, Wenshan
    Liu, Yiwen
    Li, Jixiang
    Liu, Yi
    Zhang, Xinbo
    Jia, Hui
    SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 576 : 159 - 171
  • [28] GERMANIUM IN POWER STATION BOILER PLANT
    FORREST, JS
    SMITH, AC
    WARD, JM
    NATURE, 1955, 175 (4456) : 558 - 558
  • [29] OXIDATIVE DESTRUCTION OF THIOUREA IN BOILER CHEMICAL CLEANING WASTE SOLUTIONS
    FROST, JG
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (09) : 1871 - 1874
  • [30] Microbial degradation of EDTA in an industrial wastewater treatment plant
    Kaluza, U
    Klingelhöfer, P
    Taeger, K
    WATER RESEARCH, 1998, 32 (09) : 2843 - 2845