Simultaneous quantification of multiple classes of phenolic compounds in blood plasma by liquid chromatography-electrospray tandem mass spectrometry

被引:83
作者
Chang, Hong [1 ]
Wan, Yi [1 ]
Naile, Jonathan [1 ]
Zhang, Xiaowei [1 ]
Wiseman, Steve [1 ]
Hecker, Markus [1 ,2 ]
Lam, Michael H. W. [3 ]
Giesy, John P. [1 ,3 ,4 ,5 ,6 ,7 ]
Jones, Paul D. [1 ]
机构
[1] Univ Saskatchewan, Toxicol Ctr, Saskatoon, SK S7N 5B3, Canada
[2] ENTRIX Inc, Saskatoon, SK S7N 5B3, Canada
[3] Univ Saskatchewan, Dept Vet Biomed Sci, Saskatoon, SK S7N 5B3, Canada
[4] City Univ Hong Kong, Ctr Coastal Pollut & Conservat, Hong Kong, Hong Kong, Peoples R China
[5] City Univ Hong Kong, Dept Biol & Chem, Hong Kong, Hong Kong, Peoples R China
[6] Michigan State Univ, Dept Zool, E Lansing, MI 48824 USA
[7] Michigan State Univ, Ctr Integrat Toxicol, E Lansing, MI 48824 USA
关键词
BPA; BRPs; Derivatization; Estrogens; LC-ESI-MS/MS; OH-PBDEs; POLYBROMINATED DIPHENYL ETHERS; FLOUNDER PLATICHTHYS-FLESUS; BISPHENOL-A; ESTROGENIC ACTIVITY; HUMAN SERUM; IN-VITRO; METABOLITES; WATER; DERIVATIZATION; ESTRADIOL;
D O I
10.1016/j.chroma.2009.11.076
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method using high performance liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) in positive ion mode was developed for the simultaneous analysis of 30 phenolic compounds, including four estrogens, bisphenol A (BPA), 10 hydroxylated polybrominated dephenyl ethers (OH-PBDEs) and 15 bromophenols (BRPs), in blood plasma. In the present method, derivatization with dansyl chloride was employed, and all the derivertized target compounds were well resolved on a 100 mm Xbridge C18 column with acetonitrile and 0.1% formic acid as the mobile phases. Purification procedures, such as liquid-liquid extraction and silica-gel chromatography, were applied to reduce matrix effects in the sample extract and remove excess derivatizing reagents, thus permitting selective and sensitive detection of the target phenolic compounds. The limit of quantification for all analytes, with a signal-to-noise ratio of similar to 10, was 2-30 pg/g(plasma weight) except for 6-OH-BDE-137 (30 pg/g) and 3-BRP(60 pg/g). The method was validated for recoveries (68-100%), accuracy (84-110%) and precision (3.7-11%) using charcoal-stripped bovine blood plasma spiked with all target compounds (500 and 5000 pg/mL). Finally, the method was applied to analyze six blood plasma samples from frogs and cormorants, where two natural estrogens, one BPA, one OH-PBDE and four BRPs were detected. The greatest total concentrations of estrogens coincided with the least total concentrations of other phenolic compounds for both species. The proposed method based on derivatization followed by LC-MS/MS provides a novel method to simultaneously monitor multiple groups of phenolic compounds in blood plasma. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:506 / 513
页数:8
相关论文
共 34 条
[1]   Survey of estrogenic activity in United Kingdom estuarine and coastal waters and its effects on gonadal development of the flounder Platichthys flesus [J].
Allen, Y ;
Scott, AP ;
Matthiessen, P ;
Haworth, S ;
Thain, JE ;
Feist, S .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1999, 18 (08) :1791-1800
[2]   Derivatization of ethinylestradiol with dansyl chloride to enhance electrospray ionization: Application in trace analysis of ethinylestradiol in rhesus monkey plasma [J].
Anari, MR ;
Bakhtiar, R ;
Zhu, B ;
Huskey, S ;
Franklin, RB ;
Evans, DC .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4136-4144
[3]   Measurement of bisphenol A levels in human urine [J].
Brock, JW ;
Yoshimura, Y ;
Barr, JR ;
Maggio, VL ;
Graiser, SR ;
Nakazawa, H ;
Needham, LL .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2001, 11 (04) :323-328
[4]   Assessment of river contamination by estrogenic compounds in Paris area (France) [J].
Cargouët, M ;
Perdiz, D ;
Mouatassim-Souali, A ;
Tamisier-Karolak, S ;
Levi, Y .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 324 (1-3) :55-66
[5]   Determination of steroid sex hormones and related synthetic compounds considered as endocrine disrupters in water by liquid chromatography-diode array detection-mass spectrometry [J].
de Alda, MJL ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) :391-406
[6]   Simultaneous analysis of 17α-estradiol and 17β-estradiol in bovine serum by liquid chromatography-tandem mass spectrometry [J].
Ferretti, Giovanni ;
Ferranti, Carolina ;
Crovella, Teresa ;
Fiori, Maurizio ;
Civitareale, Cinzia ;
Marchiafava, Camilla ;
delli Quadri, Fernanda ;
Cammarata, Paolo ;
Palleschi, Luca .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (01) :135-140
[7]   A comparison of the estrogenic potencies of estradiol, ethynylestradiol, diethylstilbestrol, nonylphenol and methoxychlor in vivo and in vitro [J].
Folmar, LC ;
Hemmer, MJ ;
Denslow, ND ;
Kroll, K ;
Chen, J ;
Cheek, A ;
Richman, H ;
Meredith, H ;
Grau, EG .
AQUATIC TOXICOLOGY, 2002, 60 (1-2) :101-110
[8]   Liquid chromatography/multi-stage mass spectrometry of bisphenol A and its halogenated derivatives [J].
Gallart-Ayala, Hector ;
Moyano, Encarnacion ;
Galceran, Maria T. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (24) :4039-4048
[9]   Rapid measurement of estrogens and their metabolites in human serum by liquid chromatography-tandem mass spectrometry without derivatization [J].
Guo, Tiedong ;
Gu, Jianghong ;
Soldin, Offie P. ;
Singh, Ravinder J. ;
Soldin, Steven J. .
CLINICAL BIOCHEMISTRY, 2008, 41 (09) :736-741
[10]   Effects of 20 PBDE metabolites on steroidogenesis in the H295R cell line [J].
He, Yuhe ;
Murphy, Margaret B. ;
Yu, Richard M. K. ;
Lam, Michael H. W. ;
Hecker, Markus ;
Giesy, John P. ;
Wu, Rudolf S. S. ;
Lam, Paul K. S. .
TOXICOLOGY LETTERS, 2008, 176 (03) :230-238