Effect of differences in serum creatinine estimation methodologies on estimated glomerular filtration rate

被引:7
作者
Lee, Su-Chu [1 ]
Lim, Lee-Moay [1 ,2 ]
Chang, Eddy-Essen [1 ]
Chiu, Yi-Wen [1 ,3 ]
Hwang, Shang-Jyh [1 ,3 ]
Chen, Hung-Chun [1 ,3 ]
机构
[1] Kaohsiung Med Univ Hosp, Div Nephrol, Dept Internal Med, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Coll Med, Fac Med, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ, Coll Med, Fac Renal Care, Kaohsiung, Taiwan
关键词
glomerular filtration rate; laboratory devices; measurement; serum creatinine; CHRONIC KIDNEY-DISEASE; EQUATION; JAFFE; RISK;
D O I
10.11622/smedj.2019115
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
INTRODUCTION Serum creatinine is crucial in glomerular filtration rate (GFR) estimation. Various methods of measuring GFR have been developed, which vary in their ability to estimate the prevalence of chronic kidney disease (CKD) and predict consequences associated with CKD. The use of different laboratory devices also results in uncertainty in estimated GFR (eGFR). The purpose of our study was to discuss the effect of differences in laboratory devices on eGFR when performing serum creatinine measurements. METHODS 163 participants aged 51.22 +/- 18.66 years were enrolled during a community health screening programme conducted on 18 June 2011. Samples were sent to four different hospitals using four different devices to check serum creatinine by the Jaffe and enzymatic creatinine methods. RESULTS Using Roche Cobas Integra 400, Beckman LX20, Hitachi 7180 and Toshiba TBA - c8000, the proportion of the population with eGFR < 60 mL/min/1.73 m(2) was 11.04%, 6.75%, 20.25% and 20.86%, respectively. Moreover, 3.68% of the participants had eGFR < 60 mL/min/1.73 m(2) in the laboratory when Roche Cobas Integra 400 was used with the enzymatic creatinine method and compensated Jaffe method. CONCLUSION Although standardisation of serum creatinine measurement has been achieved by using isotope dilution mass spectrometry, differences in measurement devices still cause substantial bias in the overall results. This affects the application of GFR in the estimation of CKD progression and outcomes associated with CKD.
引用
收藏
页码:468 / 473
页数:6
相关论文
共 50 条
[11]   Serum Creatinine Concentration and Creatinine-Based Estimation of Glomerular Filtration Rate in Athletes [J].
Giuseppe Banfi ;
Massimo Del Fabbro ;
Giuseppe Lippi .
Sports Medicine, 2009, 39 :331-337
[12]   Estimation of glomerular filtration rate from serum creatinine and cystatin C in octogenarians and nonagenarians [J].
Marcelo B Lopes ;
Lara Q Araújo ;
Michelle T Passos ;
Sonia K Nishida ;
Gianna M Kirsztajn ;
Maysa S Cendoroglo ;
Ricardo C Sesso .
BMC Nephrology, 14
[13]   Estimation of glomerular filtration rate from serum creatinine and cystatin C in octogenarians and nonagenarians [J].
Lopes, Marcelo B. ;
Araujo, Lara Q. ;
Passos, Michelle T. ;
Nishida, Sonia K. ;
Kirsztajn, Gianna M. ;
Cendoroglo, Maysa S. ;
Sesso, Ricardo C. .
BMC NEPHROLOGY, 2013, 14
[14]   Comparison of 12-Hour Creatinine Clearance and Estimated Glomerular Filtration Rate in Renal Transplant Recipients [J].
Kumar, Rakesh ;
Pendyala, Prashant ;
Attwood, Kris ;
Gray, Vanessa ;
Venuto, Rocco ;
Tornatore, Kathleen .
RENAL FAILURE, 2013, 35 (03) :333-337
[15]   CREATININE FOR ESTIMATION OF GLOMERULAR-FILTRATION RATE [J].
HELLERSTEIN, S ;
ALON, U ;
WARADY, BA .
PEDIATRIC NEPHROLOGY, 1992, 6 (06) :507-511
[16]   Acute kidney injury: time to shift from creatinine to the estimated glomerular filtration rate? [J].
Lippi, Giuseppe ;
Guidi, Gian Cesare .
CRITICAL CARE, 2008, 12 (04)
[17]   Estimation of Glomerular Filtration Rate by Using Serum Cystatin C and Serum Creatinine Concentrations in Patients with Human Immunodeficiency Virus [J].
Beringer, Paul M. ;
Owens, Heather ;
Nguyen, Albert ;
Mordwinkin, Nick ;
Louie, Stan ;
Mak, May ;
Sattler, Fred .
PHARMACOTHERAPY, 2010, 30 (10) :1004-1010
[18]   Acute kidney injury: time to shift from creatinine to the estimated glomerular filtration rate? [J].
Giuseppe Lippi ;
Gian Cesare Guidi .
Critical Care, 12
[19]   Estimated glomerular filtration rate: time for a performance review? [J].
Glassock, Richard J. .
KIDNEY INTERNATIONAL, 2009, 75 (10) :1001-1003
[20]   Discrepancy between estimated glomerular filtration rate by creatinine versus cystatin C in different patient care settings [J].
Liu, Li ;
Chang, Daniel Y. ;
Lewandrowski, Kent B. ;
Dighe, Anand S. .
CLINICAL BIOCHEMISTRY, 2024, 131