Effect of differences in serum creatinine estimation methodologies on estimated glomerular filtration rate

被引:7
|
作者
Lee, Su-Chu [1 ]
Lim, Lee-Moay [1 ,2 ]
Chang, Eddy-Essen [1 ]
Chiu, Yi-Wen [1 ,3 ]
Hwang, Shang-Jyh [1 ,3 ]
Chen, Hung-Chun [1 ,3 ]
机构
[1] Kaohsiung Med Univ Hosp, Div Nephrol, Dept Internal Med, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Coll Med, Fac Med, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ, Coll Med, Fac Renal Care, Kaohsiung, Taiwan
关键词
glomerular filtration rate; laboratory devices; measurement; serum creatinine; CHRONIC KIDNEY-DISEASE; EQUATION; JAFFE; RISK;
D O I
10.11622/smedj.2019115
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
INTRODUCTION Serum creatinine is crucial in glomerular filtration rate (GFR) estimation. Various methods of measuring GFR have been developed, which vary in their ability to estimate the prevalence of chronic kidney disease (CKD) and predict consequences associated with CKD. The use of different laboratory devices also results in uncertainty in estimated GFR (eGFR). The purpose of our study was to discuss the effect of differences in laboratory devices on eGFR when performing serum creatinine measurements. METHODS 163 participants aged 51.22 +/- 18.66 years were enrolled during a community health screening programme conducted on 18 June 2011. Samples were sent to four different hospitals using four different devices to check serum creatinine by the Jaffe and enzymatic creatinine methods. RESULTS Using Roche Cobas Integra 400, Beckman LX20, Hitachi 7180 and Toshiba TBA - c8000, the proportion of the population with eGFR < 60 mL/min/1.73 m(2) was 11.04%, 6.75%, 20.25% and 20.86%, respectively. Moreover, 3.68% of the participants had eGFR < 60 mL/min/1.73 m(2) in the laboratory when Roche Cobas Integra 400 was used with the enzymatic creatinine method and compensated Jaffe method. CONCLUSION Although standardisation of serum creatinine measurement has been achieved by using isotope dilution mass spectrometry, differences in measurement devices still cause substantial bias in the overall results. This affects the application of GFR in the estimation of CKD progression and outcomes associated with CKD.
引用
收藏
页码:468 / 473
页数:6
相关论文
共 50 条
  • [1] Differences in glomerular filtration rate estimation due to serum creatinine assay
    Gonzalez-Revalderia, J.
    Pascual, T.
    De Paula, M.
    Del Amo, N.
    Martinez, R.
    Miravalles, E.
    JOURNAL OF HYPERTENSION, 2006, 24 : S106 - S106
  • [2] An investigation into the accuracy of using serum creatinine estimated glomerular filtration rate to predict measured glomerular filtration rate
    Hutton, Lawrence G.
    Porter, Charlotte A.
    Morgan, Andrew J.
    Bradley, Kevin M.
    McGowan, Daniel R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (04) : 349 - 352
  • [3] ESTIMATION OF GLOMERULAR FILTRATION-RATE FROM SERUM CREATININE
    HEIERLI, C
    THOLEN, H
    BARTELS, H
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1972, 97 (03) : 67 - &
  • [4] The effect of serum creatinine measured with different assays on formula based estimated glomerular filtration rate
    Sezer, Sevilay
    Celik, H. Tugrul
    Sahingoz, Seyda
    Gungor, Oya Torun
    Yildirimkaya, M. Metin
    Turhan, Serpil
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2012, 37 (04): : 471 - 477
  • [5] Estimation of glomerular filtration rate with creatinine
    Juan Pablo Huidobro, E.
    Tagle, Rodrigo
    Maria Guzman, Ana
    REVISTA MEDICA DE CHILE, 2018, 146 (03) : 344 - 350
  • [6] Effect of alcohol consumption on estimated glomerular filtration rate and creatinine clearance rate
    Chung, FM
    Yang, YH
    Shieh, TY
    Shin, SJ
    Tsai, JCR
    Lee, YJ
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 (08) : 1610 - 1616
  • [8] Serum Creatinine Concentration and Creatinine-Based Estimation of Glomerular Filtration Rate in Athletes
    Giuseppe Banfi
    Massimo Del Fabbro
    Giuseppe Lippi
    Sports Medicine, 2009, 39 : 331 - 337
  • [9] USE OF SERUM CREATININE CONCENTRATION FOR ESTIMATION OF GLOMERULAR-FILTRATION RATE
    HELLERSTEIN, S
    ALON, U
    BLOWEY, D
    KAPLAN, R
    WARADY, BA
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1993, 147 (07): : 719 - 720
  • [10] Serum Creatinine Concentration and Creatinine-Based Estimation of Glomerular Filtration Rate in Athletes
    Banfi, Giuseppe
    Del Fabbro, Massimo
    Lippi, Giuseppe
    SPORTS MEDICINE, 2009, 39 (04) : 331 - 337