3D-Printed PCL/PLA Composite Stents: Towards a New Solution to Cardiovascular Problems

被引:129
作者
Guerra, Antonio J. [1 ]
Cano, Paula [2 ]
Rabionet, Marc [1 ,2 ]
Puig, Teresa [2 ]
Ciurana, Joaquim [1 ]
机构
[1] Univ Girona, Dept Mech Engn & Civil Construct, C Maria Aurelia Capmany 61, Girona 17003, Spain
[2] Univ Girona, Fac Med, Dept Med Sci, Emili Grahit 77, Girona 17003, Spain
关键词
3D-printing; stent; bioabsorbable; bioresorbable; polymer; composite; DRUG-ELUTING STENTS; POLYCAPROLACTONE STENT; DEGRADATION; ENDOTHELIALIZATION; FABRICATION; SCAFFOLDS; BEHAVIOR; POLYMER; DESIGN;
D O I
10.3390/ma11091679
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Biodegradable stents (BRS) offer enormous potential but first they must meet five specific requirements: (i) their manufacturing process must be precise; (ii) degradation should have minimal toxicity; (iii) the rate of degradation should match the recovery rate of vascular tissue; (iv) ideally, they should induce rapid endothelialization to restore the functions of vascular tissue, but at the same time reduce the risk of restenosis; and (v) their mechanical behavior should comply with medical requirements, namely, the flexibility required to facilitate placement but also sufficient radial rigidity to support the vessel. Although the first three requirements have been comprehensively studied, the last two have been overlooked. One possible way of addressing these issues would be to fabricate composite stents using materials that have different mechanical, biological, or medical properties, for instance, Polylactide Acid (PLA) or Polycaprolactone (PCL). However, fashioning such stents using the traditional stent manufacturing process known as laser cutting would be impossible. Our work, therefore, aims to produce PCL/PLA composite stents using a novel 3D tubular printer based on Fused Deposition Modelling (FDM). The cell geometry (shape and area) and the materials (PCL and PLA) of the stents were analyzed and correlated with 3T3 cell proliferation, degradation rates, dynamic mechanical and radial expansion tests to determine the best parameters for a stent that will satisfy the five strict BRS requirements. Results proved that the 3D-printing process was highly suitable for producing composite stents (approximately 85-95% accuracy). Both PCL and PLA demonstrated their biocompatibility with PCL stents presenting an average cell proliferation of 12.46% and PLA 8.28% after only 3 days. Furthermore, the PCL/PLA composite stents demonstrated their potential in degradation, dynamic mechanical and expansion tests. Moreover, and regardless of the order of the layers, the composite stents showed (virtually) medium levels of degradation rates and mechanical modulus. Radially, they exhibited the virtues of PCL in the expansion step (elasticity) and those of PLA in the recoil step (rigidity). Results have clearly demonstrated that composite PCL/PLA stents are a highly promising solution to fulfilling the rigorous BRS requirements.
引用
收藏
页数:13
相关论文
共 26 条
[1]   Higher Molecular Weight Polyethylene Glycol Increases Cell Proliferation While Improving Barrier Function in an In Vitro Colon Cancer Model [J].
Bharadwaj, Shruthi ;
Vishnubhotla, Ramana ;
Shan, Sun ;
Chauhan, Chinmay ;
Cho, Michael ;
Glover, Sarah C. .
JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2011,
[2]   The first systematic analysis of 3D rapid prototyped poly(ε-caprolactone) scaffolds manufactured through BioCell printing: the effect of pore size and geometry on compressive mechanical behaviour and in vitro hMSC viability [J].
Domingos, M. ;
Intranuovo, F. ;
Russo, T. ;
De Santis, R. ;
Gloria, A. ;
Ambrosio, L. ;
Ciurana, J. ;
Bartolo, P. .
BIOFABRICATION, 2013, 5 (04)
[3]   Mechanical properties of laser cut poly(L-lactide) micro-specimens: Implications for stent design, manufacture, and sterilization [J].
Grabow, N ;
Schlun, M ;
Sternberg, K ;
Hakansson, N ;
Kramer, S ;
Schmitz, KP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (01) :25-31
[4]   Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones [J].
Guan, Ying ;
Wang, Lu ;
Lin, Jing ;
King, Martin W. .
Materials, 2016, 9 (08)
[5]   A novel 3D additive manufacturing machine to biodegradable stents [J].
Guerra, A. ;
Roca, A. ;
de Ciurana, J. .
MANUFACTURING ENGINEERING SOCIETY INTERNATIONAL CONFERENCE 2017 (MESIC 2017), 2017, 13 :718-723
[6]   Fibre laser cutting of polymer tubes for stents manufacturing [J].
Guerra, A. ;
de Ciurana, J. .
MANUFACTURING ENGINEERING SOCIETY INTERNATIONAL CONFERENCE 2017 (MESIC 2017), 2017, 13 :190-196
[7]   Effects of different sterilization processes on the properties of a novel 3D-printed polycaprolactone stent [J].
Guerra, Antonio J. ;
Cano, Paula ;
Rabionet, Marc ;
Puig, Teresa ;
Ciurana, Joaquim .
POLYMERS FOR ADVANCED TECHNOLOGIES, 2018, 29 (08) :2327-2335
[8]   3D-printed bioabsordable polycaprolactone stent: The effect of process parameters on its physical features [J].
Guerra, Antonio J. ;
Ciurana, Joaquim .
MATERIALS & DESIGN, 2018, 137 :430-437
[9]   Fabrication of PCL/PLA composite tube for stent manufacturing [J].
Guerra, Antonio J. ;
San, Joan ;
Ciurana, Joaquim .
3RD CIRP CONFERENCE ON BIOMANUFACTURING, 2017, 65 :231-235
[10]   Tubular nanofiber scaffolds for tissue engineered small-diameter vascular grafts [J].
He, Wei ;
Ma, Zuwei ;
Teo, Wee Eong ;
Dong, Yi Xiang ;
Robless, Peter Ashley ;
Lim, Thiam Chye ;
Ramakrishna, Seeram .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 90A (01) :205-216