All fiber polarization insensitive detection for spectrometer based optical coherence tomography using optical switch

被引:4
|
作者
Otuya, David Odeke [1 ,2 ]
Sharma, Gargi [3 ]
Tearney, Guillermo J. [1 ,2 ]
Singh, Kanwarpal [3 ]
机构
[1] Massachusetts Gen Hosp, BAR 806,40 Blossom St, Boston, MA 02114 USA
[2] Harvard Med Sch, Shattuck St, Boston, MA 02115 USA
[3] Max Planck Inst Sci Light, Staudtstr 2, D-91058 Erlangen, Germany
关键词
CAMERA;
D O I
10.1364/OSAC.2.003465
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Polarization dependent image artifacts are common in optical coherence tomography imaging. Polarization insensitive detection scheme for swept source based optical coherence tomography systems is well established but is yet to be demonstrated for all fiber spectrometer-based Fourier domain optical coherence tomography systems. In this work, we present an all fiber polarization insensitive detection scheme for spectrometer based optical coherence tomography systems. Images from chicken breast muscle tissue were acquired to demonstrate the effectiveness of this scheme for the conventional Fourier domain optical coherence tomography system. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:3465 / 3470
页数:6
相关论文
共 50 条
  • [21] Miniaturized all fiber probe for optical coherence tomography and pH detection of biological tissue
    Chen, Minghui
    Wang, Jianping
    Tan, Weijie
    Feng, Yuanyuan
    Zheng, Gang
    JOURNAL OF BIOPHOTONICS, 2021, 14 (02)
  • [22] Single mode fiber based polarization sensitive optical coherence tomography using a swept laser source
    Sharma, P.
    Verma, Y.
    Rao, K. D.
    Gupta, P. K.
    JOURNAL OF OPTICS, 2011, 13 (11)
  • [23] Optical fiber characterization by optical coherence tomography
    Saccon, Fernando A. M.
    Muller, Marcia
    Fabris, Jose L.
    2009 SBMO/IEEE MTT-S INTERNATIONAL MICROWAVE AND OPTOELECTRONICS CONFERENCE (IMOC 2009), 2009, : 615 - 618
  • [24] Polarization sensitive full-field optical coherence tomography based on bi-stable polarization switch
    Park, Kwan Seob
    Choi, Woo June
    Eom, Tae Joong
    Kim, Jae Hun
    Woo, Deok Ha
    Lee, Byeong Ha
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XX, 2013, 8589
  • [25] Detection of drusen by polarization-sensitive optical coherence tomography
    Schlanitz, F. G.
    Ahlers, C.
    Baumann, B.
    Spalek, T.
    Schriefl, S.
    Schuetze, C.
    Pircher, M.
    Goetzinger, E.
    Hitzenberger, C. K.
    Schmidt-Erfurth, U.
    ACTA OPHTHALMOLOGICA, 2010, 88 : 36 - 37
  • [26] Determination of characteristics of degenerative joint disease using optical coherence tomography and polarization sensitive optical coherence tomography
    Xie, Tuqiang
    Guo, Shuguang
    Zhang, Jun
    Chen, Zhongping
    Peavy, George M.
    LASERS IN SURGERY AND MEDICINE, 2006, 38 (09) : 852 - 865
  • [27] Improved optical axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography
    Lu, Zenghai
    Matcher, Stephen J.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVII, 2013, 8571
  • [28] All optical fiber combined-imaging system of photoacoustic and optical coherence tomography
    Eom, Jonghyun
    Shin, Jun Geun
    Park, Soongho
    Lee, Byeong Ha
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2016, 2016, 9708
  • [29] Comment on "optical-fiber-based Mueller optical coherence tomography"
    Park, BH
    Pierce, MC
    de Boer, JF
    OPTICS LETTERS, 2004, 29 (24) : 2873 - 2874
  • [30] Implementation of all-fiber optical delay line and applications for optical coherence tomography
    Lee, BH
    Choi, ES
    APBP 2004: SECOND ASIAN AND PACIFIC RIM SYMPOSIUM ON BIOPHOTONICS, PROCEEDINGS, 2004, : 8 - 9