Calibration of 4π NaI(Tl) detectors with coincidence summing correction using new numerical procedure and ANGLE4 software

被引:36
作者
Badawi, Mohamed S. [1 ,2 ]
Jovanovic, Slobodan I. [3 ,4 ]
Thabet, Abouzeid A. [5 ]
El-Khatib, Ahmed M. [1 ]
Dlabac, Aleksandar D. [3 ]
Salem, Bohaysa A. [6 ]
Gouda, Mona M. [1 ]
Mihaljevic, Nikola N. [3 ,7 ]
Almugren, Kholud S. [8 ]
Abbas, Mahmoud I. [1 ]
机构
[1] Univ Alexandria, Dept Phys, Fac Sci, Alexandria 21511, Egypt
[2] Beirut Arab Univ, Dept Phys, Fac Sci, Beirut, Lebanon
[3] Univ Montenegro, Ctr Nucl Competence & Knowledge Management, Podgorica, Montenegro
[4] Univ Montenegro, Fac Math & Nat Sci, Dept Phys, Podgorica, Montenegro
[5] Pharos Univ Alexandria, Fac Allied Med Sci, Dept Med Equipment Technol, Alexandria, Egypt
[6] Pharos Univ Alexandria, Fac Phys Therapy, Dept Basic Sci, Alexandria, Egypt
[7] Univ Montenegro, Maritime Fac, Dept Math, Kotor, Montenegro
[8] Princess Nourah Bint Abdulrahaman Univ, Dept Phys, Fac Sci, Riyadh 1154455532, Saudi Arabia
关键词
GAMMA-RAY DETECTORS; SCINTILLATION DETECTORS; EFFICIENCY CALIBRATION; POINT; SPECTROMETRY; GEOMETRIES; NAI; GE;
D O I
10.1063/1.4978214
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The 4 pi NaI(Tl) gamma-ray detectors are consisted of the well cavity with cylindrical cross section, and the enclosing geometry of measurements with large detection angle. This leads to exceptionally high efficiency level and a significant coincidence summing effect, much more than a single cylindrical or coaxial detector especially in very low activity measurements. In the present work, the detection effective solid angle in addition to both full-energy peak and total efficiencies of well-type detectors, were mainly calculated by the new numerical simulation method (NSM) and ANGLE4 software. To obtain the coincidence summing correction factors through the previously men-tioned methods, the simulation of the coincident emission of photons was modeled mathematically, based on the analytical equations and complex integrations over the radioactive volumetric sources including the self-attenuation factor. The measured full-energy peak efficiencies and correction factors were done by using Eu-152, where an exact adjustment is required for the detector efficiency curve, because neglecting the coincidence summing effect can make the results inconsistent with the whole. These phenomena, in general due to the efficiency calibration process and the coincidence summing corrections, appear jointly. The full-energy peak and the total efficiencies from the two methods typically agree with discrepancy 10%. The discrepancy between the simulation, ANGLE4 and measured full-energy peak after corrections for the coincidence summing effect was on the average, while not exceeding 14%. There-fore, this technique can be easily applied in establishing the efficiency calibration curves of well-type detectors. (C) 2017 Author(s).
引用
收藏
页数:19
相关论文
共 34 条
[1]   Analytical formulae for borehole scintillation detectors efficiency calibration [J].
Abbas, Mahmoud I. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01) :171-175
[2]   A new analytical method to calibrate cylindrical phoswich and LaBr3(Ce) scintillation detectors [J].
Abbas, Mahmoud I. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3) :413-418
[3]   Analytical approach to calculate the efficiency of 4π NaI(Tl) gamma-ray detectors for extended sources [J].
Abbas, Mahmoud I. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 615 (01) :48-52
[4]   Calculation of relative full-energy peak efficiencies of well-type detectors [J].
Abbas, MI ;
Selim, YS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 480 (2-3) :651-657
[5]   Analytical formulae for well-type NaI (Tl) and HPGe detectors efficiency computation [J].
Abbas, MI .
APPLIED RADIATION AND ISOTOPES, 2001, 55 (02) :245-252
[6]   Coincidence summing corrections for a clover detector [J].
Agarwal, Chhavi ;
Danu, L. S. ;
Gathibandhe, M. ;
Goswami, A. ;
Biswas, D. C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 763 :240-247
[7]  
[Anonymous], 1995, NISTIR
[8]   Accurate calculation of well-type detector geometrical efficiency using sources with different shapes and geometries [J].
Badawi, M. S. .
JOURNAL OF INSTRUMENTATION, 2015, 10
[9]   New numerical simulation approach to calibrate the NaI(Tl) detectors array using non-axial extended spherical sources [J].
Badawi, M. S. ;
El-Khatib, A. M. ;
Krar, M. E. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[10]   Efficiency calibration and coincidence summing correction for a 4πNaI(Tl detector array [J].
Byun, SH ;
Prestwich, WV ;
Chin, K ;
McNeill, FE ;
Chettle, DR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (03) :674-685