Galvanic corrosion properties of steel in water saturated concrete

被引:5
|
作者
Ahlstrom, J. [1 ]
Tidblad, J. [1 ]
Sandberg, B. [1 ]
Wadso, L. [2 ]
机构
[1] Swerea KIMAB, S-16440 Kista, Sweden
[2] Lund Univ, Div Bldg Mat, SE-22100 Lund, Sweden
来源
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION | 2015年 / 66卷 / 01期
关键词
REINFORCING STEEL; BEHAVIOR;
D O I
10.1002/maco.201307141
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Aluminum-based sacrificial anodes were installed to reinforced concrete to stop ongoing corrosion in cooling water tunnels in a Swedish nuclear power plant. The steel rebars were also unintentionally connected to stainless steel water pumps. Therefore, the consumption rate of the sacrificial anodes was higher than predicted. An experimental and a field study were performed to assess if the steel rebar suffer from galvanic corrosion and if the stainless steel pumps are responsible alone for the high consumption rate. It was found from the experimental study that there is an increased risk of galvanic corrosion for steel rebar when the corrosion potential is raised to -200mV (SCE) for samples with 1% Cl- by mass of cement and -500mV (SCE) for samples with 2% Cl- by mass of cement. The experimental results were compared with the corrosion potential measured in the cooling water tunnel where sacrificial anodes were in use and not mounted at all. The cooling water tunnel without sacrificial anodes had generally more anodic corrosion potentials compared to the tunnel with anodes. The tunnel with anodes had also more anodic potentials closer to the stainless steel pumps than further away which means that the rebar is affected by the stainless steel pumps. However, the measured corrosion potentials in the tunnels were not as anodic as the potentials needed for high galvanic current measured in the experimental study.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 50 条
  • [1] GALVANIC CORROSION OF REINFORCING STEEL EXPOSED TO CONCRETE AND WATER
    VRABLE, JB
    MATERIALS PERFORMANCE, 1982, 21 (03) : 51 - 52
  • [2] Galvanic corrosion of steel in concrete
    C.I.S.C., Madrid, Spain
    Mater Sci Forum, pt 2 (899-906):
  • [3] A GALVANIC SENSOR FOR MONITORING CORROSION OF STEEL IN CARBONATED CONCRETE
    SHORT, NR
    PAGE, CL
    GLASS, GK
    MAGAZINE OF CONCRETE RESEARCH, 1991, 43 (156) : 149 - 154
  • [4] STRAY CURRENT AND GALVANIC CORROSION OF REINFORCING STEEL IN CONCRETE
    MILLER, RL
    HARTT, WH
    BROWN, RP
    MATERIALS PERFORMANCE, 1976, 15 (05) : 20 - 27
  • [5] INVESTIGATION OF THE EFFECT OF GALVANIC CORROSION BETWEEN STEEL IN CONCRETE AND STEEL IN SOIL
    ABEL, HJ
    KRUSE, CL
    WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1982, 33 (02): : 89 - 93
  • [6] A Galvanic Sensor for Monitoring the Corrosion Condition of the Concrete Reinforcing Steel: Relationship Between the Galvanic and the Corrosion Currents
    Pereira, Elsa Vaz
    Figueira, Rita Bacelar
    Lemos Salta, Maria Manuela
    Elias da Fonseca, Ines Teodora
    SENSORS, 2009, 9 (11) : 8391 - 8398
  • [7] Investigation of the Effect of Galvanic Corrosion Between Steel in Concrete and Steel in Soil.
    Abel, H.J.
    Kruse, C.L.
    Werkstoffe und Korrosion, 1982, 33 (02): : 89 - 93
  • [8] Influence of steel-concrete interface condition on galvanic corrosion currents in carbonated concrete
    Nasser, A.
    Clement, A.
    Laurens, S.
    Castel, A.
    CORROSION SCIENCE, 2010, 52 (09) : 2878 - 2890
  • [9] General and galvanic corrosion of steel weldments in synthetic sea water
    Sozhan, G
    Ramu, S
    BULLETIN OF ELECTROCHEMISTRY, 1996, 12 (1-2): : 55 - 58
  • [10] Galvanic corrosion of duplex corrosion-resistant steel rebars under carbonated concrete conditions
    Jiang, Jinyang
    Chu, Hong-yan
    Liu, Yao
    Wang, Danqian
    Guo, Dong
    Sun, Wei
    RSC ADVANCES, 2018, 8 (30): : 16626 - 16635