Assessment of LV ejection fraction using real-time 3D echocardiography in daily practice: direct comparison of the volumetric and speckle tracking methodologies to CMR

被引:24
作者
Driessen, M. M. P. [1 ,2 ]
Kort, E. [1 ]
Cramer, M. J. M. [1 ]
Doevendans, P. A. [1 ]
Angevaare, M. J.
Leiner, T. [3 ]
Meijboom, F. J. [1 ]
Chamuleau, S. A. J. [1 ]
Sieswerda, G. Tj [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Cardiol, NL-3584 CX Utrecht, Netherlands
[2] Netherlands Heart Inst, ICIN, NL-3511 GC Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
关键词
Real-time 3D echocardiography; Daily practice; Observer experience; CMR; LEFT-VENTRICULAR VOLUMES; CARDIOVASCULAR MAGNETIC-RESONANCE; 3-DIMENSIONAL ECHOCARDIOGRAPHY; HEART-FAILURE; QUANTIFICATION; REPRODUCIBILITY; ACCURACY; MRI;
D O I
10.1007/s12471-014-0577-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims This study is the first to directly compare two widely used real-time 3D echocardiography (RT3DE) methods of cardiac magnetic resonance imaging (CMR) and assess their reproducibility in experienced and less experienced observers. Methods Consecutive patients planned for CMR underwent RT3DE within 8 h of CMR with Philips (volumetric method) and Toshiba Artida (speckle tracking method). Left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume (LVEDV) and end-systolic volume (LVESV) were measured using RT3DE, by four trained observers, and compared with CMR values. Results Thirty-five patients were included (49.7+/-15.7 years; 55 % male), 30 (85.7 %) volumetric and 27 (77.1 %) speckle tracking datasets could be analysed. CMR derived LVEDV, LVESV and LVEF were 198+/-58 ml, 106+/-53 ml and 49+/-15 %, respectively. LVEF derived from speckle tracking was accurate and reproducible in all observers (all intra-class correlation coefficients (ICC)>0.86). LVEF derived from the volumetric method correlated well to CMR in experienced observers (ICC 0.85 and 0.86) but only moderately in less experienced observers (ICC 0.58 and 0.77) and was less reproducible in these observers (ICC=0.55). Volumes were significantly underestimated compared with CMR (p<0.001). Conclusion This study demonstrates that both RT3DE methodologies are sufficiently accurate and reproducible for use in daily practice. However, experience importantly influences the accuracy and reproducibility of the volumetric method, which should be considered when introducing this technique into clinical practice.
引用
收藏
页码:383 / 390
页数:8
相关论文
共 23 条
[11]   Assessment of Intraventricular Mechanical Dyssynchrony and Prediction of Response to Cardiac Resynchronization Therapy: Comparison between Tissue Doppler Imaging and Real-Time Three-Dimensional Echocardiography [J].
Kleijn, Sebastiaan A. ;
van Dijk, Jeroen ;
de Cock, Carel C. ;
Allaart, Cor P. ;
van Rossum, Albert C. ;
Kamp, Otto .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (09) :1047-1054
[12]   Automated analysis of three-dimensional stress echocardiography [J].
Leung, K. Y. E. ;
van Stralen, M. ;
Danilouchkine, M. G. ;
van Burken, G. ;
Geleijnse, M. L. ;
Reiber, J. H. C. ;
de Jong, N. ;
van der Steen, A. F. W. ;
Bosch, J. G. .
NETHERLANDS HEART JOURNAL, 2011, 19 (06) :307-310
[13]   Automated border detection in three-dimensional echocardiography: principles and promises [J].
Leung, K. Y. Esther ;
Bosch, Johan G. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (02) :97-108
[14]   Cardiovascular magnetic resonance imaging: Current and emerging applications [J].
Lima, JAC ;
Desal, MY .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (06) :1164-1171
[15]   Comparison of real-time three-dimensional echocardiography with cardiovascular magnetic resonance for left ventricular volumetric assessment in unselected patients [J].
Miller, Christopher A. ;
Pearce, Keith ;
Jordan, Peter ;
Argyle, Rachel ;
Clark, David ;
Stout, Martin ;
Ray, Simon G. ;
Schmitt, Matthias .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (02) :187-195
[16]   Real Time Three-Dimensional Echocardiographic Assessment of Left Ventricular Function in Heart Failure Patients: Underestimation of Left Ventricular Volume Increases with the Degree of Dilatation [J].
Moceri, Pamela ;
Doyen, Denis ;
Bertora, David ;
Cerboni, Pierre ;
Ferrari, Emile ;
Gibelin, Pierre .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (08) :970-977
[17]   Real-Time 3-Dimensional Echocardiographic Quantification of Left Ventricular Volumes [J].
Mor-Avi, Victor ;
Jenkins, Carly ;
Kuehl, Harald P. ;
Nesser, Hans-Joachim ;
Marwick, Thomas ;
Franke, Andreas ;
Ebner, Christian ;
Freed, Benjamin H. ;
Steringer-Mascherbauer, Regina ;
Pollard, Heidi ;
Weinert, Lynn ;
Niel, Johannes ;
Sugeng, Lissa ;
Lang, Roberto M. .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (04) :413-423
[18]   Predictors of mortality and morbidity in patients with chronic heart failure [J].
Pocock, SJ ;
Wang, DL ;
Pfeffer, MA ;
Yusuf, S ;
McMurray, JJV ;
Swedberg, KB ;
Östergren, J ;
Michelson, EL ;
Pieper, KS ;
Granger, CB .
EUROPEAN HEART JOURNAL, 2006, 27 (01) :65-75
[19]   Accuracy and reproducibility of quantitation of left ventricular function by real-time three-dimensional echocardiography versus cardiac magnetic resonance [J].
Soliman, Osama I. I. ;
Kirschbaum, Sharon W. ;
van Dalen, Bas M. ;
van der Zwaan, Heleen B. ;
Delavary, Babak Mahdavian ;
Vletter, Wim B. ;
van Geuns, Robert-Jan M. ;
Ten Cate, Folkert J. ;
Geleijnse, Marcel L. .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (06) :778-783
[20]   Quantitative assessment of left ventricular size and function - Side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference [J].
Sugeng, Lissa ;
Mor-Avi, Victor ;
Weinert, Lynn ;
Niel, Johannes ;
Ebner, Christian ;
Steringer-Mascherbauer, Regina ;
Schmidt, Frank ;
Galuschky, Christian ;
Schummers, Georg ;
Lang, Roberto M. ;
Nesser, Hans-Joachim .
CIRCULATION, 2006, 114 (07) :654-661