Electrochemical glucose biosensing via new generation DTP type conducting polymers/gold nanoparticles/glucose oxidase modified electrodes

被引:20
作者
Azak, Hacer [1 ]
Kurbanoglu, Sevinc [2 ]
Yildiz, Huseyin Bekir [3 ]
Ozkan, Sibel A. [2 ]
机构
[1] Karamanoglu Mehmetbey Univ, Dept Chem, TR-70100 Karaman, Turkey
[2] Ankara Univ, Fac Pharm, Dept Analyt Chem, TR-06100 Ankara, Turkey
[3] KTO Karatay Univ, Dept Mat Sci & Nanotechnol Engn, TR-42020 Konya, Turkey
关键词
Glucose biosensors; Conducting polymers; Gold nanoparticles; Aniline modified GOx; IMMOBILIZATION; TYROSINASE; DESIGN; MATRIX; CARBON; SENSOR;
D O I
10.1016/j.jelechem.2016.03.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The synthesis of derivatives of dithionepyrrole is a hot subject that has been studied extensively. In this study, a novel approach for constructing different glucose biosensors using conducting polymers of 4-(4H-dithyinol[3,2-b:2',3'-d]pyro11-4-yl)aniline and 4-(4H-dithyinol[3,2-b:2',3'-d]pyroll-4-yl)-[1,1'-biphenyl]-4-amine is proposed. After the synthesis and characterizations of the dithionepyrrole type monomers, they were used in glucose biosensing applications. The surface of gold electrode was modified with mercaptoethane sulfonic acid and paminothiophenol functionalized gold nanoparticles and aniline modified GOx. Electrochemical measurements were carried out by following the consumed oxygen due to the enzymatic reaction of glucose oxidase. DTP-PhNH2/AuNP/GOx and DTP-Ph-Ph-NH2/AuNP/GOx biosensors showed very good linearity between 0.1 and 2.5 mM, and 0.05 and 1 mM for glucose, respectively. LOD value was obtained for pDTP-Ph-NH2/AuNP/GOx as 5.00 x 10(-2) mM and for pDTP-Ph-Ph-NH2/AuNP/GOx as 9.86 x 10(-5) mM using S/N ratio. Optimization of molar ratio amount of AuNP/GOx, cycles amount to immobilize AuNP/GOx, conducting polymer thickness were examined. Finally, under optimized conditions, the amount of glucose in spiked human serum samples and recovery experiments were conducted. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 97
页数:8
相关论文
共 44 条
[1]   Biomolecular immobilization on conducting polymers for biosensing applications [J].
Ahuja, Tarushee ;
Mir, Irfan Ahmad ;
Kumar, Devendra ;
Rajesh .
BIOMATERIALS, 2007, 28 (05) :791-805
[2]   Poly-(3-hexylthiophene) self-assembled monolayer based cholesterol biosensor using surface plasmon resonance technique [J].
Arya, Sunil K. ;
Solanki, Pratima R. ;
Singh, S. P. ;
Kaneto, K. ;
Pandey, Manoj K. ;
Datta, Monika ;
Malhotra, Bansi D. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2516-2524
[3]   Ferrocene-Functionalized 4-(2,5-Di(thiophen-2-yl)-1H-pyrrol-1-yl)aniline: A Novel Design in Conducting Polymer-Based Electrochemical Biosensors [J].
Ayranci, Rukiye ;
Demirkol, Dilek Odaci ;
Ak, Metin ;
Timur, Suna .
SENSORS, 2015, 15 (01) :1389-1403
[4]   Synthesis of an amine-functionalized naphthalene-containing conducting polymer as a matrix for biomolecule immobilization [J].
Azak, Hacer ;
Guler, Emine ;
Can, Ummugulsum ;
Demirkol, Dilek Odaci ;
Yildiz, Huseyin Bekir ;
Talaz, Oktay ;
Timur, Suna .
RSC ADVANCES, 2013, 3 (42) :19582-19590
[5]   Electrochromic device and bulk heterojunction solar cell applications of poly 4,7-bis(2,3-dihydrothieno[3,4-b][1,4] dioxin-5-yl)-2-dodecyl-2H-benzo[1,2,3]triazole (PBEBT) [J].
Balan, Abidin ;
Baran, Derya ;
Sariciftci, Niyazi Serdar ;
Toppare, Levent .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2010, 94 (10) :1797-1802
[6]   Electrochemical preparation of polypyrrole colloids using a flow cell [J].
Barisci, JN ;
Mansouri, J ;
Spinks, GM ;
Wallace, GG ;
Kim, CY ;
Kim, DY ;
Kim, JY .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1997, 126 (2-3) :129-135
[7]   Electronic and Optical Properties of 4H-Cyclopenta[2,1-b•3,4-b′]bithiophene Derivatives and Their 4-Heteroatom-Substituted Analogues: A Joint Theoretical and Experimental Comparison [J].
Barlow, Stephen ;
Odom, Susan A. ;
Lancaster, Kelly ;
Getmanenko, Yulia A. ;
Mason, Richard ;
Coropceanu, Veaceslav ;
Bredas, Jean-Luc ;
Marder, Seth R. .
JOURNAL OF PHYSICAL CHEMISTRY B, 2010, 114 (45) :14397-14407
[8]   A conducting polymer with benzothiadiazole unit: Cell based biosensing applications and adhesion properties [J].
Baskurt, Eylul ;
Ekiz, Fulya ;
Demirkol, Dilek Odaci ;
Timur, Suna ;
Toppare, Levent .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 97 :13-18
[9]   Bio-bar-code functionalized magnetic nanoparticle label for ultrasensitive flow injection chemiluminescence detection of DNA hybridization [J].
Bi, Sai ;
Zhou, Hong ;
Zhang, Shusheng .
CHEMICAL COMMUNICATIONS, 2009, (37) :5567-5569
[10]   BIO-SENSORS BASED ON ION-SELECTIVE ELECTRODES [J].
CAMMANN, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1977, 287 (01) :1-9