Reduction in thrombotic events with heparin-coated Palmaz-Schatz stents in normal porcine coronary arteries

被引:175
作者
Hardhammar, PA
vanBeusekom, HMM
Emanuelsson, HU
Hofma, SH
Albertsson, PA
Verdouw, PD
Boersma, E
Serruys, PW
vanderGiessen, WJ
机构
[1] ERASMUS UNIV ROTTERDAM, THORAXCTR, DEPT CARDIOL, 3015 GD ROTTERDAM, NETHERLANDS
[2] SAHLGRENS UNIV HOSP, DIV CARDIOL, GOTHENBURG, SWEDEN
关键词
stents; thrombosis; heparin;
D O I
10.1161/01.CIR.93.3.423
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The use of stents improves the result after balloon coronary angioplasty. Thrombogenicity of stents is, however, a concern. In the present study, we compared stents with an antithrombotic coating with regular stents. Methods and Results Regular stents were placed in coronary arteries of pigs receiving no aspirin (group 1; n=8) or aspirin over 4 weeks (group 2, n=10) or 12 weeks (group 3, n=9). Stents coated with heparin (antithrombin III uptake, 5 pmol/stent) were placed in 7 pigs that did not receive aspirin (group 4). The other animals received aspirin and coated stents with a heparin activity of 12 pmol antithrombin III/stent (group 5, n=10) or 20 pmol/stent (group 6, n=10; group 7, n=10). Quantitative arteriography was performed at implantation and after 4 (groups 1, 2, and 4 through 6) or 12 weeks (groups 3 and 7). In an additional 5 animals, five regular and five coated stents (20 pmolistent) were placed and explanted after 5 days for examination of the early responses to the implants. Thrombotic occlusion of the regular stent occurred in 9 of 27 in groups 1 through 3. However, in 0 of 30 of the animals receiving high activity heparin-coated stents (groups 5 through 7), thrombotic stent occlusion was observed (P<.001). Histological analysis at 4 weeks showed that the neointima in group 6 was thicker compared with its control group 2 (259+/-104 and 117+/-36 mu m, P<.01), but at 12 weeks the thickness was similar (152+/-61 and 198+/-49 mu m, respectively). Comparison at 5 days suggested delayed endothelialization of the coating. Conclusions High-activity heparin coating of stents eliminates subacute thrombosis in porcine coronary arteries.
引用
收藏
页码:423 / 430
页数:8
相关论文
共 50 条
[41]   A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495
[42]   CO-IMMOBILIZATION AND INTERACTION OF HEPARIN AND PLASMIN ON COLLAGENO-ELASTIC TUBES [J].
SHANKAR, H ;
SENATORE, F ;
WU, DR ;
AVANTSA, S .
BIOMATERIALS ARTIFICIAL CELLS AND ARTIFICIAL ORGANS, 1990, 18 (01) :59-73
[43]   INTRAVASCULAR STENTS TO PREVENT OCCLUSION AND RESTENOSIS AFTER TRANS-LUMINAL ANGIOPLASTY [J].
SIGWART, U ;
PUEL, J ;
MIRKOVITCH, V ;
JOFFRE, F ;
KAPPENBERGER, L .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (12) :701-706
[44]   RANDOMIZED TRIAL OF CORONARY INTERVENTION WITH ANTIBODY AGAINST PLATELET IIB/IIIA INTEGRIN FOR REDUCTION OF CLINICAL RESTENOSIS - RESULTS AT 6 MONTHS [J].
TOPOL, EJ ;
CALIFF, RM ;
WEISMAN, HF ;
ELLIS, SG ;
TCHENG, JE ;
WORLEY, S ;
IVANHOE, R ;
GEORGE, BS ;
FINTEL, D ;
WESTON, M ;
SIGMON, K ;
ANDERSON, KM ;
LEE, KL ;
WILLERSON, JT ;
SMITH, CR ;
WEISMAN, H .
LANCET, 1994, 343 (8902) :881-886
[45]   CAVEATS ABOUT ELECTIVE CORONARY STENTING [J].
TOPOL, EJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :539-541
[46]   CORONARY STENTING WITH POLYMER-COATED AND UNCOATED SELF-EXPANDING ENDOPROSTHESES IN PIGS [J].
VANDERGIESSEN, WJ ;
VANBEUSEKOM, HMM ;
VANHOUTEN, CD ;
VANWOERKENS, LJ ;
VERDOUW, PD ;
SERRUYS, PW .
CORONARY ARTERY DISEASE, 1992, 3 (07) :631-640
[47]   CORONARY STENTING WITH A NEW, RADIOPAQUE, BALLOON-EXPANDABLE ENDOPROSTHESIS IN PIGS [J].
VANDERGIESSEN, WJ ;
SERRUYS, PW ;
VANBEUSEKOM, HMM ;
VANWOERKENS, LJ ;
VANLOON, H ;
SOEI, LK ;
STRAUSS, BH ;
BEATT, KJ ;
VERDOUW, PD .
CIRCULATION, 1991, 83 (05) :1788-1798
[48]  
VIDEM V, 1991, J THORAC CARDIOV SUR, V101, P654
[49]  
VONSEGESSER LK, 1991, ASAIO T, V37, P278
[50]   STABILITY OF THROMBUS-RESISTANT GRAPHITE-BENZALKONIUM-HEPARIN SURFACE IN ANTI-HEPARIN ENVIRONMENT [J].
WHIFFEN, JD ;
GOTT, VL ;
YOUNG, WP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1964, 48 (02) :317-&