Ruggedness testing of quantitative atmospheric pressure ionization mass spectrometry methods: the effect of co-injected matrix on matrix effects

被引:40
作者
Heller, David N. [1 ]
机构
[1] US FDA, Ctr Vet Med, Laurel, MD 20708 USA
关键词
D O I
10.1002/rcm.2882
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A number of techniques have been suggested to date for assessing matrix effects on quantitative atmospheric pressure ionization mass spectrometry (API-LC/MS) methods. A newly designed experiment has the aim of efficiently simulating the quantitative behavior of an LC/MS method as a function of the amount of co-injected matrix extract. Two sets of mixtures were prepared in different formats to study matrix effects as a function of analyte or matrix amount. Chromatographic conditions were varied as well, to alter the separation between analyte and co-extractants, and thereby provide different matrix effect conditions for testing the same mixtures. Graphical presentation of the results was used to gain insight into the matrix effect phenomenon. The results suggest that ruggedness for API-LC/MS methods may be defined as the absence of significant variation in results as a function of the amount of co-injected matrix. That is, a non-rugged API-LC/MS method may give consistent results only if a fixed amount of matrix is co-injected on a specific instrument. The results also point to the existence of a specific matrix concentration for the onset of matrix effects, below which these effects are not significant. These issues are important to the US FDA Center for Veterinary Medicine, which has regulatory authority for methods used to monitor for drug residues in food tissues from animals. The ruggedness testing technique suggested here may be an important factor in determining that a method is ready for multi-laboratory testing on multiple instruments.
引用
收藏
页码:644 / 652
页数:9
相关论文
共 25 条
  • [1] Ion suppression in mass spectrometry
    Annesley, TM
    [J]. CLINICAL CHEMISTRY, 2003, 49 (07) : 1041 - 1044
  • [2] ENHANCED SENSITIVITY FOR PEPTIDE-MAPPING WITH ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY IN THE PRESENCE OF SIGNAL SUPPRESSION DUE TO TRIFLUOROACETIC ACID-CONTAINING MOBILE PHASES
    APFFEL, A
    FISCHER, S
    GOLDBERG, G
    GOODLEY, PC
    KUHLMANN, FE
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) : 177 - 190
  • [3] Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO
  • [4] 2-0
  • [5] CAMS R, 2003, J AM SOC MASS SPECTR, V14, P1290
  • [6] Determination of SCH 211803 by nanoelectrospray infusion mass spectrometry: evaluation of matrix effect and comparison with liquid chromatography-tandem mass spectrometry
    Chen, JW
    Yang, LY
    Kapron, JT
    Ma, L
    Pace, E
    Van Pelt, CK
    Rudewicz, PJ
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 205 - 210
  • [7] Analysis of cyanobacterial toxins by hydrophilic interaction liquid chromatography-mass spectrometry
    Dell'Aversano, C
    Eaglesham, GK
    Quilliam, MA
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1028 (01) : 155 - 164
  • [8] Food and Drug Administration Center for Drug Evaluation and Research, GUID IND BIOAN METH
  • [9] Reduction of signal suppression effects in ESI-MS using a nanosplitting device
    Gangl, ET
    Annan, M
    Spooner, N
    Vouros, P
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (23) : 5635 - 5644
  • [10] KING R, 1998, P 46 ASMS C MASS SPE, P150