Active Cancelation of Equivalent Grid Impedance for Improving Stability and Injected Power Quality of Grid-Connected Inverter Under Variable Grid Condition

被引:44
作者
He, Yuanbin [1 ]
Chung, Henry Shu-Hung [2 ]
Lai, Chun-Tak [2 ]
Zhang, Xin [3 ]
Wu, Weimin [4 ]
机构
[1] Hangzhou Dianzi Univ, Res Inst Elect Engn & Automat, Hangzhou 310000, Zhejiang, Peoples R China
[2] City Univ Hong Kong, Ctr Smart Energy Convers & Utilizat Res, Hong Kong, Hong Kong, Peoples R China
[3] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[4] Shanghai Maritime Univ, Res Inst Elect Automat, Shanghai 201306, Peoples R China
基金
中国国家自然科学基金;
关键词
Grid impedance cancelator; impedance-based stability criterion; inductive-capacitive-inductive (LCL) filter; negative virtual grid impedance; single-phase inverters; weak grid; LCL-FILTER; DESIGN;
D O I
10.1109/TPEL.2018.2793459
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An active grid impedance cancelator using the concept of series active filter to suppress the effect of the grid disturbance and stabilize the single-phase grid-connected inverters with an inductive-capacitive-inductive filter operating under variable grid condition is presented. Harmonic interaction between the inverter and the grid is thereby avoided owing to the cancelation of equivalent grid impedance. More importantly, the impedance cancelator offers an active damping function to ease the heavy burden of the inverter control, such as power control, phase locked loop, current regulation, impedance shaping, etc. The impedance cancelator is a full-bridge dc-ac converter having no passive inductive-capacitive filter. It is connected in series with the inverter output and is operated as a negative virtual grid impedance. As the voltampere rating of the impedance cancelator is low, the efficiency of the entire system is not sacrificed. Starting with the impedance-based analytical modeling method, the basic principle of equivalent grid impedance cancelator is derived and studied. Then, the digital control strategy and the modeling of equivalent grid impedance cancelator are examined. The experimental results of a prototype cancellator for a single-phase inverter are favorably compared with theoretical predictions.
引用
收藏
页码:9387 / 9398
页数:12
相关论文
共 29 条
  • [1] Overview of control and grid synchronization for distributed power generation systems
    Blaabjerg, Frede
    Teodorescu, Remus
    Liserre, Marco
    Timbus, Adrian V.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1398 - 1409
  • [2] A Time Delay Compensation Method Based on Area Equivalence For Active Damping of an LCL-Type Converter
    Chen, Chen
    Xiong, Jian
    Wan, Zhiqiang
    Lei, Ji
    Zhang, Kai
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (01) : 762 - 772
  • [3] Harmonic interaction between a large number of distributed power inverters and the distribution network
    Enslin, JHR
    Heskes, PJM
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (06) : 1586 - 1593
  • [4] Dynamic Phasors-Based Modeling and Stability Analysis of Droop-Controlled Inverters for Microgrid Applications
    Guo, Xiaoqiang
    Lu, Zhigang
    Wang, Baocheng
    Sun, Xiaofeng
    Wang, Lei
    Guerrero, Josep M.
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (06) : 2980 - 2987
  • [5] Investigation and Active Damping of Multiple Resonances in a Parallel-Inverter-Based Microgrid
    He, Jinwei
    Li, Yun Wei
    Bosnjak, Dubravko
    Harris, Brent
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (01) : 234 - 246
  • [6] Generalized Closed-Loop Control Schemes with Embedded Virtual Impedances for Voltage Source Converters with LC or LCL Filters
    He, Jinwei
    Li, Yun Wei
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (04) : 1850 - 1861
  • [7] Direct Current Tracking Using Boundary Control With Second-Order Switching Surface for Three-Phase Three-Wire Grid-Connected Inverter
    He, Yuanbin
    Chung, Henry Shu-hung
    Ho, Carl Ngai-Man
    Wu, Weimin
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (07) : 5723 - 5740
  • [8] Use of Boundary Control With Second-Order Switching Surface to Reduce the System Order for Deadbeat Controller in Grid-Connected Inverter
    He, Yuanbin
    Chung, Henry Shu-Hung
    Ho, Carl Ngai-Man
    Wu, Weimin
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (03) : 2638 - 2653
  • [9] He YB, 2014, IEEE ENER CONV, P4450, DOI 10.1109/ECCE.2014.6953730
  • [10] Korytowski M. J., 2014, THESIS