Effect of intravenous ondansetron on maternal hemodynamics during elective caesarean section under subarachnoid block

被引:3
作者
Attri, Ankita [1 ]
Sharma, Namrata [2 ]
Singh, Mirley R. [2 ]
Bansal, Kamya [2 ]
Singh, Sahil [3 ]
机构
[1] Max Hosp, Dept Anaesthesia, Mohali, India
[2] DMCH, Dept Anaesthesia, 1st Floor, Ludhiana 141001, Punjab, India
[3] Adesh Inst Med Sci & Res, Bathinda, Punjab, India
关键词
Bezold-Jarisch reflex; caesarean section; hypotension; ondansetron; serotonin; subarachnoid block;
D O I
10.4103/joacc.JOACC_27_19
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: The Bezold-Jarisch reflex (BJR) is considered to contribute to subarachnoid block (SAB)-induced hypotension and bradycardia and is mediated by serotonin receptors (5-HT3 subtype). Ondansetron, a 5-HT3 receptor antagonist, is assumed to block the effect of serotonin and inhibit BJR. The aim was to study the effect of intravenous ondansetron on maternal hemodynamics. Materials and Methods: The study was conducted on 150 healthy parturients scheduled for elective caesarean section under SAB who were randomly allocated into two groups of 75 each to receive either 4 mg ondansetron or 0.9% normal saline 10 min before initiation of SAB. Hemodynamic parameters were studied from the time of administration of the study drug upto the time of delivery of baby. Results: Both the groups were comparable to each other with respect to baseline hemodynamic parameters. SAB-induced fall in systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean arterial pressure (MAP) was significantly less in the ondansetron group when compared with placebo from the time of initiation of SAB upto 12 min of surgery time (P < 0.05). However, the difference in heart rate between both groups was not statistically significant. The total use of vasopressors was significantly low in ondansetron group when compared with placebo (P < 0.05). Better neonatal outcomes were observed in the ondansetron group. Conclusion: Intravenous ondansetron premedication can successfully attenuate SAB-induced fall in SBP, DBP, and MAP in parturients undergoing elective caesarean sections.
引用
收藏
页数:5
相关论文
共 18 条
[1]  
Johnson E, 2017, INDIAN J ANAESTH, V61, P285, DOI 10.4103/ija.IJA_209_17
[2]  
Kalra Seema, 2011, J Anaesthesiol Clin Pharmacol, V27, P541, DOI 10.4103/0970-9185.86604
[3]  
Marashi SM., 2014, ANESTH PAIN MED, V4, P120
[4]  
Marciniak A, 2015, GINEKOL POL, V86, P461
[5]   Vasopressors in obstetric anesthesia: A current perspective [J].
Nag, Deb Sanjay ;
Samaddar, Devi Prasad ;
Chatterjee, Abhishek ;
Kumar, Himanshu ;
Dembla, Ankur .
WORLD JOURNAL OF CLINICAL CASES, 2015, 3 (01) :58-64
[6]   Effect of intravenous ondansetron on reducing the incidence of hypotension and bradycardia events during shoulder arthroscopy in sitting position under interscalene brachial plexus block: A prospective randomized trial [J].
Nallam, Srinivasa Rao ;
Dara, Sudheer .
INDIAN JOURNAL OF ANAESTHESIA, 2015, 59 (06) :353-358
[7]   The Third American Society of Regional Anesthesia and Pain Medicine Practice Advisory on Local Anesthetic Systemic Toxicity: Executive Summary 2017 [J].
Neal, Joseph M. ;
Barrington, Michael J. ;
Fettiplace, Michael R. ;
Gitman, Marina ;
Memtsoudis, Stavros G. ;
Morwald, Eva E. ;
Rubin, Daniel S. ;
Weinberg, Guy .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2018, 43 (02) :113-123
[8]   The effect of intravenous ondansetron on maternal haemodynamics during elective caesarean delivery under spinal anaesthesia: a double-blind, randomised, placebo-controlled trial [J].
Ortiz-Gomez, J. R. ;
Palacio-Abizanda, F. J. ;
Morillas-Ramirez, F. ;
Fornet-Ruiz, I. ;
Lorenzo-Jimenez, A. ;
Bermejo-Albares, M. L. .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2014, 23 (02) :138-143
[9]   Ondansetron given intravenously attenuates arterial blood pressure drop due to spinal anesthesia: A double-blind, placebo-controlled study [J].
Owczuk, Radoslaw ;
Wenski, Wojciech ;
Polak-Krzeminska, Agnieszka ;
Twardowski, Pawel ;
Arszulowicz, Renata ;
Dylczyk-Sommer, Anna ;
Wujtewicz, Magdalena A. ;
Sawicka, Wioletta ;
Morzuch, Ewa ;
Smietanski, Maciej ;
Wujtewicz, Maria .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2008, 33 (04) :332-339
[10]   Overview of anesthetic considerations for Cesarean delivery [J].
Rollins, Mark ;
Lucero, Jennifer .
BRITISH MEDICAL BULLETIN, 2012, 101 (01) :105-125