Amorphous silicon, semiconductor X-ray converter detectors for protein crystallography

被引:15
|
作者
Ross, S [1 ]
Zentai, G [1 ]
Shah, KS [1 ]
Alkire, RW [1 ]
Naday, I [1 ]
Westbrook, EM [1 ]
机构
[1] RADIAT MONITORING DEVICES INC,WATERTOWN,MA 02172
关键词
X-ray detector; amorphous silicon; protein crystallography; lead iodide;
D O I
10.1016/S0168-9002(97)00793-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Hydrogenated amorphous silicon (a-Si:H) is a semiconductor material which call be inexpensively deposited to create a large array detector or readout structure. Combining it with a suitable semiconductor X-ray sensitive converter would produce a large, sensitive detector for X-rays with energies of 6-20 keV such as used in measurements of diffraction patterns for protein crystallography. In these experiments, the diffraction patterns created when X-rays strike crystallized protein samples are used to infer the physical structure of the molecules. The requirements for the detector include the ability to record signal peaks to high diffraction order to obtain accurate mapping of the electron density of the protein molecule, plus rapid sampling of the diffraction pattern to minimize radiation dose to the exposed crystal, while maintaining high signal-to-noise ratios. In this paper we summarize our results to date measuring and modeling the suitability of various semiconductor thin films for direct X-ray detection, and of the noise and readout properties of an amorphous silicon matrix array, We provide sample diffraction patterns obtained from a protein crystal taken at the Argonne Advanced Photon Source X-ray synchrotron using a phosphor coated a-Si: H array.
引用
收藏
页码:38 / 50
页数:13
相关论文
共 50 条
  • [21] Performance of silicon-drift detectors in kaonic atom X-ray measurements
    Bazzi, M.
    Beer, G.
    Bombelli, L.
    Bragadireanu, A. M.
    Cargnelli, M.
    Corradi, G.
    Curceanu , C.
    d'Uffizi, A.
    Fiorini, C.
    Frizzi, T.
    Ghio, F.
    Girolami, B.
    Guaraldo, C.
    Hayano, R. S.
    Iliescu, M.
    Ishiwatari, T.
    Iwasaki, M.
    Kienle, P.
    Sandri, P. Levi
    Longoni, A.
    Lucherini, V.
    Marton, J.
    Okada, S.
    Pietreanu, D.
    Ponta, T.
    Rizzo, A.
    Vidal, A. Romero
    Scordo, A.
    Shi, H.
    Sirghi, D. L.
    Sirghi, F.
    Tatsuno, H.
    Tudorache, A.
    Tudorache, V.
    Doce, O. Vazquez
    Widmann, E.
    Zmeskal, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01) : 264 - 267
  • [22] Temporal artefacts in flat dynamic X-ray detectors
    Overdick, M
    Solf, T
    Wischmann, HA
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 47 - 58
  • [23] Structures of proteins and cofactors: X-ray crystallography
    Allen, J. P.
    Seng, C.
    Larson, C.
    PHOTOSYNTHESIS RESEARCH, 2009, 102 (2-3) : 231 - 240
  • [24] Performance characteristics needed for protein crystal diffraction X-ray detectors
    Westbrook, EM
    DETECTORS FOR CRYSTALLOGRAPHY AND DIFFRACTION STUDIES AT SYNCHROTRON SOURCES, 1999, 3774 : 2 - 16
  • [25] Structures of proteins and cofactors: X-ray crystallography
    J. P. Allen
    C. Seng
    C. Larson
    Photosynthesis Research, 2009, 102 : 231 - 240
  • [26] Combining X-ray and neutron crystallography with spectroscopy
    Kwon, Hanna
    Smith, Oliver
    Raven, Emma Lloyd
    Moody, Peter C. E.
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2017, 73 : 141 - 147
  • [27] Low-temperature crystallization of amorphous silicon and amorphous germanium by soft X-ray irradiation
    Heya, Akira
    Kanda, Kazuhiro
    Toko, Kaoru
    Sadoh, Taizoh
    Amano, Sho
    Matsuo, Naoto
    Miyamoto, Shuji
    Miyao, Masanobu
    Mochizuki, Takayasu
    THIN SOLID FILMS, 2013, 534 : 334 - 340
  • [28] Detectors for the X-Ray testing systems
    Ayzenshtat, GI
    Vilisova, MD
    Lelekov, MA
    Ivashchenko, AI
    Mokeev, DY
    Porokhovnichenko, LP
    Tolbanov, OP
    Shapoval, LG
    SIBCON-2005: IEEE International Siberian Conference on Control and Communications, 2005, : 72 - 77
  • [29] X-ray detectors in medical imaging
    Spahn, Martin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 731 : 57 - 63
  • [30] The present and future of microcalorimeter X-ray detectors for fundamental X-ray parameters
    Jach, Terrence
    Thurgate, Stephen
    Beckhoff, Burkhard
    RADIATION PHYSICS AND CHEMISTRY, 2024, 218