Amorphous silicon, semiconductor X-ray converter detectors for protein crystallography

被引:15
作者
Ross, S [1 ]
Zentai, G [1 ]
Shah, KS [1 ]
Alkire, RW [1 ]
Naday, I [1 ]
Westbrook, EM [1 ]
机构
[1] RADIAT MONITORING DEVICES INC,WATERTOWN,MA 02172
关键词
X-ray detector; amorphous silicon; protein crystallography; lead iodide;
D O I
10.1016/S0168-9002(97)00793-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Hydrogenated amorphous silicon (a-Si:H) is a semiconductor material which call be inexpensively deposited to create a large array detector or readout structure. Combining it with a suitable semiconductor X-ray sensitive converter would produce a large, sensitive detector for X-rays with energies of 6-20 keV such as used in measurements of diffraction patterns for protein crystallography. In these experiments, the diffraction patterns created when X-rays strike crystallized protein samples are used to infer the physical structure of the molecules. The requirements for the detector include the ability to record signal peaks to high diffraction order to obtain accurate mapping of the electron density of the protein molecule, plus rapid sampling of the diffraction pattern to minimize radiation dose to the exposed crystal, while maintaining high signal-to-noise ratios. In this paper we summarize our results to date measuring and modeling the suitability of various semiconductor thin films for direct X-ray detection, and of the noise and readout properties of an amorphous silicon matrix array, We provide sample diffraction patterns obtained from a protein crystal taken at the Argonne Advanced Photon Source X-ray synchrotron using a phosphor coated a-Si: H array.
引用
收藏
页码:38 / 50
页数:13
相关论文
共 27 条
[1]  
ANTONUK LE, 1991, MATER RES SOC SYMP P, V219, P531, DOI 10.1557/PROC-219-531
[2]  
ANTONUK LE, 1984, SPIE PHYS MED IMAGIN, V2163
[3]  
ARNDTAND UW, 1977, ROTATION METHOD CRYS
[4]  
Eikenberry E. F., 1991, Photoelectronic Image Devices 1991. The McGee Symposium. Proceedings of the 10th Symposium, P273
[5]   HIGH-SENSITIVITY READOUT OF 2D A-SI IMAGE SENSORS [J].
FUJIEDA, I ;
STREET, RA ;
WEISFIELD, RL ;
NELSON, S ;
NYLEN, P ;
PEREZMENDEZ, V ;
CHO, GS .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (1A) :198-204
[6]  
GLESKOVA H, 1996, IEEE ELECT DEV LETT, V17
[7]   CCD AND VIDICON X-RAY-DETECTORS - THEORY AND PRACTICE [J].
GRUNER, SM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1545-1551
[8]   CHARACTERISTICS OF A FLAT MULTIWIRE AREA DETECTOR FOR PROTEIN CRYSTALLOGRAPHY [J].
HAMLIN, R ;
CORK, C ;
HOWARD, A ;
NIELSEN, C ;
VERNON, W ;
MATTHEWS, D ;
XUONG, NH .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1981, 14 (APR) :85-93
[9]  
Hammond C., 1992, INTRO CRYSTALLOGRAPH
[10]   DETERMINATION OF MACROMOLECULAR STRUCTURES FROM ANOMALOUS DIFFRACTION OF SYNCHROTRON RADIATION [J].
HENDRICKSON, WA .
SCIENCE, 1991, 254 (5028) :51-58