The microenvironment around total hip replacement prostheses

被引:95
作者
Konttinen, YT
Zhao, DS
Beklen, A
Ma, GF
Takagi, M
Kivelä-Rajamäki, M
Ashammakhi, N
Santavirta, S
机构
[1] Univ Helsinki, Cent Hosp, Dept Med Invartes Med, Helsinki, Finland
[2] ORTON Orthopaed Hosp, Invalid Fdn, Helsinki, Finland
[3] COXA Joint Replacement Hosp, Tampere, Finland
[4] Yamagata Sch Med, Dept Orthopaed Surg, Yamagata, Japan
[5] Tampere Univ Technol, Inst Biomat, FIN-33101 Tampere, Finland
[6] Univ Helsinki, Cent Hosp, Dept Orthopaed & Traumatol, Helsinki, Finland
关键词
D O I
10.1097/01.blo.0000150451.50452.da
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The metal stem of the totally replaced hip carries load and resists fatigue, but it is electrochemically corroded. Metallic atoms act as haptens, induce type 1 T-helper cells/Th1-type immune responses and enhance periprosthetic osteolysis. Stiff metal implants, which do not have the same elasticity as the surrounding bone, cause stress shielding. Cyclic loading and lack of ligamentous support lead to mechanical and ischemia reperfusion injury and particle formation from bone, polymethylmethacrylate, and porous implant surfaces, which accelerate third-body polyethylene wear. Surgical injury and micromotion induce the formation of a fibrous capsule interface. Type-B lining cells produce lubricin and surface-active phospholipids to promote solid-to-solid lubrication but may loosen the implant from bone. The pumping action of the cyclically loaded joint and synovial fluid pressure waves dissect the implant-host interface and transports polyethylene particles and pro-inflammatory mediators to the interface. Hyaluronan induces formation of a synovial lining like layer. Because of its localization close to bone, foreign body inflammation at the interface stimulates osteoclastogenesis and peri-implant bone loss. Metal-on-metal and ceramic-on-ceramic pairs might minimize third body wear, but can lead to high-impact load of the acetabulum. Diamond coating of a metal-on-polyethylene couple might solve both of these problems. The basic biomaterial solutions allow good mechanical performance and relatively long life in-service, but surface modifications (porous coating, hydroxyapatite, diamond, bioglass, and others) may facilitate performance of the implant and improve the biomaterial and body interfaces.
引用
收藏
页码:28 / 38
页数:11
相关论文
共 78 条
[1]   LOCALIZED ENDOSTEAL BONE LYSIS IN RELATION TO THE FEMORAL COMPONENTS OF CEMENTED TOTAL HIP ARTHROPLASTIES [J].
ANTHONY, PP ;
GIE, GA ;
HOWIE, CR ;
LING, RSM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06) :971-979
[2]   Influence of materials for fixation implants on local infection - An experimental study of steel versus titanium DCP in rabbits [J].
Arens, S ;
Schlegel, U ;
Printzen, G ;
Ziegler, WJ ;
Perren, SM ;
Hansis, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (04) :647-651
[3]   The role of the TH1 and TH2 immune responses in loosening and osteolysis of cemented total hip replacements [J].
Arora, A ;
Song, Y ;
Chun, L ;
Huie, P ;
Trindade, M ;
Smith, RL ;
Goodman, S .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 64A (04) :693-697
[4]  
ASPENBERG P, 1998, CLIN ORTHOP RELAT R, V352, P75
[5]   SYNOVIAL MACROPHAGES [J].
ATHANASOU, NA .
ANNALS OF THE RHEUMATIC DISEASES, 1995, 54 (05) :392-394
[6]   The pathology of total joint arthroplasty - II. Mechanisms of implant failure [J].
Bauer, TW ;
Schils, J .
SKELETAL RADIOLOGY, 1999, 28 (09) :483-497
[7]   TNF-α secretion and macrophage mortality induced by cobalt and chromium ions in vitro-Qualitative analysis of apoptosis [J].
Catelas, I ;
Petit, A ;
Zukor, DJ ;
Antoniou, J ;
Huk, OL .
BIOMATERIALS, 2003, 24 (03) :383-391
[8]   Regulation of extracellular matrix gene expression by mechanical stress [J].
Chiquet, M .
MATRIX BIOLOGY, 1999, 18 (05) :417-426
[9]   BONE REMODELING IN THE PROXIMAL FEMUR AFTER CHARNLEY TOTAL HIP-ARTHROPLASTY [J].
COHEN, B ;
RUSHTON, N .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77 (05) :815-819
[10]  
COOK SD, 1988, CLIN ORTHOP RELAT R, V234, P90