Experimental analysis of an air conditioner powered by photovoltaic energy and supported by the grid

被引:36
作者
Aguilar, F. J. [1 ]
Aledo, S. [2 ]
Quiles, P. V. [1 ]
机构
[1] Univ Miguel Hernandez, Dept Ingn Mecan & Energia, Ave Univ S-N,Edificio Innova, Elche 03202, Spain
[2] Prointer SL, C Nicolas Bussi 30, Elche 03320, Spain
关键词
Energy efficiency; Solar energy; Photovoltaic panels; Solar heat pump; HEAT-PUMP SYSTEM; COOLING SYSTEMS; SOLAR; OPTIONS; WATER;
D O I
10.1016/j.applthermaleng.2017.05.123
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present document describes experimental work carried out on an air conditioning unit which has been powered using both a photovoltaic installation and the grid simultaneously. This document exposes the information gathered during an entire year of data collection. The control system has been designed to give priority to the renewable energy source in order to maximise solar contribution. The aim of the study is to analyse any real possibilities and the viability of the use of photovoltaic systems to supply energy to air conditioning equipment without batteries or regulators. In this case, the conventional energy source has been used to supply energy when the PV energy is insufficient. The main elements of the experimental setup were; an air conditioning unit with a nominal cooling capacity of 3.52 kW, and a photovoltaic installation with three 235 W-p panels connected directly to the equipment at 24 Vdc. The equipment has been monitored during the 12 h of daily usage (from 8 to 20 h), to condition an office with 35 m(2) in Alicante (Spain). The results during a cooling period of 6 months have demonstrated that the average EER could be close to 15. Both the solar contribution and the production factor are close to 65%. Experimental correlations are given in order to extend the obtained results to simulate other climatic conditions and demands. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:486 / 497
页数:12
相关论文
共 22 条
[1]  
[Anonymous], 2012, ENERGY EFFICIENCY ST
[2]  
[Anonymous], 1002008 JCGM
[3]   Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in hot and humid climate [J].
Beccali, Marco ;
Finocchiaro, Pietro ;
Nocke, Bettina .
SOLAR ENERGY, 2009, 83 (10) :1828-1846
[4]   Investigation of a Hybrid Solar Heat Pump System [J].
Chen, Hongbing ;
Riffat, Saffa B. .
2011 INTERNATIONAL CONFERENCE ON GREEN BUILDINGS AND SUSTAINABLE CITIES, 2011, 21 :311-318
[5]   Experimental study on a hybrid photovoltaic/heat pump system [J].
Chen, Hongbing ;
Riffat, Saffa B. ;
Fu, Yu .
APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) :4132-4138
[6]   Analysis of a solar assisted heat pump system for indoor swimming pool water and space heating [J].
Chow, T. T. ;
Bai, Y. ;
Fong, K. F. ;
Lin, Z. .
APPLIED ENERGY, 2012, 100 :309-317
[7]  
European Photovoltaic Industry Association, GLOB MARK OUTL SOL P
[8]   Comparative study of different solar cooling systems for buildings in subtropical city [J].
Fong, K. F. ;
Chow, T. T. ;
Lee, C. K. ;
Lin, Z. ;
Chan, L. S. .
SOLAR ENERGY, 2010, 84 (02) :227-244
[9]   Experimental study of a photovoltaic solar-assisted heat-pump/heat-pipe system [J].
Fu, H. D. ;
Pei, G. ;
Ji, J. ;
Long, H. ;
Zhang, T. ;
Chow, T. T. .
APPLIED THERMAL ENGINEERING, 2012, 40 :343-350
[10]   Air conditioning using an air-cooled single effect lithium bromide absorption chiller:: Results of a trial conducted in Madrid in August 2005 [J].
Izquierdo, M. ;
Lizarte, R. ;
Marcos, J. D. ;
Gutierrez, G. .
APPLIED THERMAL ENGINEERING, 2008, 28 (8-9) :1074-1081