Real-Time power control algorithm for reactive power reserve of Wind Farm

被引:2
作者
Jung, S. [1 ]
Jang, G. [1 ]
机构
[1] Korea Univ, Sch Elect Engn, Seoul 136713, South Korea
基金
新加坡国家研究基金会;
关键词
Wind farm management; reactive power assignment; continuous voltage control; reactive power reserve; wind operation;
D O I
10.1016/j.ifacol.2016.10.702
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Reactive power assignment has not been considered seriously in wind power because many system owners manage real power output firstly and maintain the required voltage for each wind turbine. However, renewable resources penetration is being continuously increased and power system operator might ask additional service to improve the reliability and stability issues. Owing to the system loss by the extensive area, the uncertainty of transferred power from large-scale wind farm is considerable. Counterbalancing the gap between expected and real output quantity is available with additional control design but reducing the occurred error is more effectual to not only the system efficiency but also the system stability. In this paper, a reactive power assignment strategy based on the relative distance of each wind turbine in farm, and realistic assignment processes to verify the positive effect are performed by PSCAD/EMTDC. The strategy is considering voltage fluctuation and system loss by two distinguished assignment processes that regarding array and turbines. (c) 2016, IFAC (International Federation of Automatic Control) Hosting by Elsevier Ltd. All rights reserved.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 8 条
[1]  
[Anonymous], 2014, TENCON 2014 2014 IEE
[2]   On Variable Reverse Power Flow-Part II: An Electricity Market Model Considering Wind Station Size and Location [J].
Gabash, Aouss ;
Li, Pu .
ENERGIES, 2016, 9 (04)
[3]   Development of an Optimal Power Control Scheme for Wave-Offshore Hybrid Generation Systems [J].
Jung, Seungmin ;
Jang, Gilsoo .
ENERGIES, 2015, 8 (09) :9009-9028
[4]   Optimal Operation Plan of the Online Electric Vehicle System Through Establishment of a DC Distribution System [J].
Jung, Seungmin ;
Lee, Hansang ;
Song, Chong Suk ;
Han, Jong-Hoon ;
Han, Woon-Ki ;
Jang, Gilsoo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (12) :5878-5889
[5]   A Variable Speed Wind Turbine Control Strategy to Meet Wind Farm Grid Code Requirements [J].
Muyeen, S. M. ;
Takahashi, Rion ;
Murata, Toshiaki ;
Tamura, Junji .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2010, 25 (01) :331-340
[6]  
Tian J, 2014, IEEE IND ELEC, P5450, DOI 10.1109/IECON.2014.7049333
[7]   Wind Farms as Reactive Power Ancillary Service Providers-Technical and Economic Issues [J].
Ullah, Nayeem Rahmat ;
Bhattacharya, Kankar ;
Thiringer, Torbjorn .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (03) :661-672
[8]   Thermal Behavior Optimization in Multi-MW Wind Power Converter by Reactive Power Circulation [J].
Zhou, Dao ;
Blaabjerg, Frede ;
Lau, Mogens ;
Tonnes, Michael .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (01) :433-440