Liquid chromatographic high-resolution mass spectrometric and tandem mass spectrometric identification of synthetic peptides, using electrospray ionization

被引:17
作者
D'Agostino, PA
Hancock, JR
Provost, LR
Semchuk, PD
Hodges, RS
机构
[1] Def Res Estab Suffield, Medicine Hat, AB T1A 8K6, Canada
[2] Univ Alberta, Dept Biochem, Edmonton, AB T6G 2H7, Canada
[3] Univ Alberta, Protein Engn Network Ctr Excellence, Edmonton, AB T6G 2H7, Canada
关键词
liquid chromatography -mass spectrometry; electrospray ionization; peptides;
D O I
10.1016/S0021-9673(97)01104-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-high-resolution electrospray mass spectrometry (LC-EST-MS) was investigated for the identification of known and unknown synthetic peptides in a research effort designed to evaluate the applicability of this and complementary MS techniques for peptide characterization and identification. The monoisotopic molecular masses of five related peptides with molecular masses between 2000 and 2500 u were acquired with a resolution of 3000 (10% valley). Under narrow and wide mass range magnetic sector scanning conditions monoisotopic molecular mass errors were typically in the 10-20 and 30-40 ppm range, respectively. Tryptic maps were generated for each peptide following LC-ESI-MS analysis and collisionally activated dissociation (CAD) in the ESI interface resulted in the production of characteristic product ions that enabled amino acid sequencing of the tryptic fragments. Unknown identification was demonstrated during analysis of an incomplete synthetic peptide reaction mixture. The synthesis of an 18 amino acid peptide, LTTAVKKVLTTGLPALIS, was not successful. In its place were six unknown peptides that were identified on the basis of monoisotopic molecular mass and amino acid sequence data. The monoisotopic molecular masses of these unknowns were determined to within 10-20 ppm with a resolution of 3500 (10% valley). Amino acid sequences for the six peptides were generated during ESI-MS-MS analysis. Finally two synthetic peptides differing only by the incorporation of a C-13 at leucine were analysed with a resolution of 6000 (10% valley) to confirm that the isotopic distributions were consistent with theoretical expectations. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:89 / 100
页数:12
相关论文
共 50 条
  • [21] Forensic toxicological determination of surfactant by liquid chromatography/electrospray ionization mass spectrometry and liquid chromatography/electrospray ionization tandem mass spectrometry
    Nishikawa, M
    Katagi, M
    Miki, A
    Tsuchihashi, H
    JOURNAL OF HEALTH SCIENCE, 2003, 49 (02) : 138 - 148
  • [22] Progress of electrospray ionization and rapid evaporative ionization mass spectrometric techniques for the broad-range identification of microorganisms
    Kailasa, Suresh Kumar
    Koduru, Janardhan Reddy
    Park, Tae Jung
    Wu, Hui-Fen
    Lin, Ying-Chi
    ANALYST, 2019, 144 (04) : 1073 - 1103
  • [23] Tandem high-resolution electrospray ionization mass spectrometry of fluorinated thevinols and 18,19-dihydrothevinols
    Eremin, D. B.
    Kadentsev, V. I.
    Sandulenko, I. V.
    Moiseev, S. K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (13) : 1561 - 1568
  • [24] Tandem high-resolution electrospray ionization mass spectrometry of fluorinated thevinols and 18,19-dihydrothevinols
    D. B. Eremin
    V. I. Kadentsev
    I. V. Sandulenko
    S. K. Moiseev
    Journal of Analytical Chemistry, 2015, 70 : 1561 - 1568
  • [25] Liquid Chromatographic and Mass Spectrometric Analysis of Dyes for Forensic Purposes
    Beck, Keith R.
    Hinks, David
    Crawford, Anne
    Weisner, Nathan
    AATCC REVIEW, 2012, 12 (01) : 60 - 65
  • [26] Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometric characterization of high molecular mass Starburst™ dendrimers
    Tolic, LP
    Anderson, GA
    Smith, RD
    Brothers, HM
    Spindler, R
    Tomalia, DA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 165 : 405 - 418
  • [27] Rapid identification of atypical tetracyclines using tandem mass spectrometric fragmentation patterns
    Sala, Martin
    Kocar, Drago
    Lukezic, Tadeja
    Kosec, Gregor
    Hodoscek, Milan
    Petkovic, Hrvoje
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (17) : 1556 - 1562
  • [28] A fast liquid chromatographic tandem mass spectrometric method for the simultaneous determination of total homocysteine and methylmalonic acid
    Hempen, Christel
    Wanschers, Harry
    Veer, Gertjan van der Sluijs
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (01) : 263 - 270
  • [29] A fast liquid chromatographic tandem mass spectrometric method for the simultaneous determination of total homocysteine and methylmalonic acid
    Christel Hempen
    Harry Wanschers
    Gertjan van der Sluijs Veer
    Analytical and Bioanalytical Chemistry, 2008, 391 : 263 - 270
  • [30] Electrospray ionization tandem mass spectrometric determination of monomethylarsonic acid and dimethylarsinic acid after adduct formation with citric acid
    Minakata, Kayoko
    Ohnishi, Kazunori
    Nakamura, Satoki
    Suzuki, Masako
    Suzuki, Osamu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (25): : 2624 - 2629